https://www.phoenixcontact.com/us/produkte/1719338
25.04.2013Page2/6
PCB terminal block-SPT 5/ 4-V-7,5-ZB-1719338
Technical data
Technical data
Range of articles SPT 5/..-V
Insulating material group I
Rated surge voltage (III/3) 8 kV
Rated surge voltage (III/2) 8 kV
Rated surge voltage (II/2) 6 kV
Rated voltage (III/3) 800 V
Rated voltage (III/2) 1000 V
Rated voltage (II/2) 1000 V
Connection in acc. with standard EN-VDE
Nominal current IN41 A
Nominal cross section 6 mm²
Maximum load current 41 A
Insulating material PA
Inflammability class according to UL 94 V0
Stripping length 15 mm
Nominal voltage, UL/CUL Use Group B 600 V
Nominal current, UL/CUL Use Group B 35 A
Nominal voltage, UL/CUL Use Group C 600 V
Nominal current, UL/CUL Use Group C 35 A
Connection data
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 10 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 6 mm²
Conductor cross section stranded, with ferrule without plastic sleeve min. 0.25 mm²
Conductor cross section stranded, with ferrule without plastic sleeve max. 6 mm²
Conductor cross section stranded, with ferrule with plastic sleeve min. 0.25 mm²
Conductor cross section stranded, with ferrule with plastic sleeve max. 4 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 8
2 conductors with same cross section, stranded, TWIN ferrules with plastic
sleeve, min. 0.25 mm²
2 conductors with same cross section, stranded, TWIN ferrules with plastic
sleeve, max. 1.5 mm²
Minimum AWG according to UL/CUL 24
Maximum AWG according to UL/CUL 8