ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage VRRM , maximum repetitive V RSM , maximum non- IRRM max.
Type number Code peak reverse voltage repetitive peak rev. voltage @ TJ max.
VVmA
08 800 900
12 1200 1300
16 1600 1700
20 2000 2100
IRKD600.. 50
IF(AV) Maximum average forward current 600 A 180° conduction, half sine wave
@ Case temperature 100 °C
IF(RMS) Maximum RMS forward current 9 42 A 180° conduction, half sine wave @ TC = 100°C
IFSM Maximum peak, one-cycle forward, 19.0 KA t = 10ms No voltage
non-repetitive surge current 20.1 t = 8.3ms reapplied
16.2 t = 10ms 100% VRRM
17.2 t = 8.3ms reapplied Sinusoidal half wave,
I2t Maximum I2t for fusing 1805 KA2s t = 10ms No voltage Initial TJ = TJ max.
1683 t = 8.3ms reapplied
1319 t = 10ms 100% VRRM
1230 t = 8.3ms reapplied
I2√t Maximum I2√t for fusing 18050 KA2√s t = 0.1 to 10ms, no voltage reapplied
VF(TO)1 Low level value of threshold voltage 0.70 V (16.7% x π x I F(AV) < I < π x IF(AV)), TJ = TJ max.
VF(TO)2 High level value of threshold voltage 0.77 (I > π x IF(AV)), TJ = TJ max.
rf1 Low level value of forward slope resistance 0.28 mΩ(16.7% x π x I F(AV) < I < π x IF(AV)), TJ = TJ max.
rf2 High level value of forward slope resistance 0.25 (I > π x IF(AV)), TJ = TJ max.
VFM Maximum forward voltage drop 1.24 V Ipk = 1800A, TJ = 25°C, tp = 10ms sine pulse
Parameter IRKD600.. Units Conditions
Forward Conduction
VINS RMS isolation voltage 3000 V t = 1 s
IRRM Maximum peak reverse and off-state 50 mA TJ = TJ max., rated VRRM applied
leakage current
Parameter IRKD600.. Units Conditions
Blocking