Test Devices Attenuators Attenuators Dampfungsglieder Attenuators RPC- N 50 , Stecker - Stecker RPC- N 50 , male - male Return Loss Attenuation Tolerance Power Handling x05 AS 102- S03 S3 a = 51.5 mm 26.4 dB @ DC to 4 GHz 3 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- S06 S3 a = 51.5 mm 26.4 dB @ DC to 4 GHz 6 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- S10 S3 a = 51.5 mm 26.4 dB @ DC to 4 GHz 10 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.6 dB @ 12.4 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- S20 S3 a = 51.5 mm 26.4 dB @ DC to 4 GHz 20 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 4 GHz 0.5 dB @ 8 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- S30 S3 a = 51.5 mm 26.4 dB @ DC to 4 GHz 30 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.8 dB @ 4 GHz 1.0 dB @ 12.4 GHz 1.5 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- S40 S3 a = 59.2 mm 26.4 dB @ DC to 4 GHz 40 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.8 dB @ 4 GHz 1.0 dB @ 12.4 GHz 1.5 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C SW20 SW20 RPC- N 50 , Stecker - Kuppler Return Loss Attenuation Tolerance Power Handling x05 AS 102- K03 S3 a = 49.5 mm 26.4 dB @ DC to 4 GHz 3 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- K06 S3 a = 49.5 mm 26.4 dB @ DC to 4 GHz 6 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- K10 S3 a = 49.5 mm 26.4 dB @ DC to 4 GHz 10 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.6 dB @ 12.4 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- K20 S3 a = 49.5 mm 26.4 dB @ DC to 4 GHz 20 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 4 GHz 0.5 dB @ 8 GHz 0.8 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- K30 S3 a = 49.5 mm 26.4 dB @ DC to 4 GHz 30 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.8 dB @ 4 GHz 1.0 dB @ 12.4 GHz 1.5 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 102- K40 S3 a = 57.5 mm 26.4 dB @ DC to 4 GHz 40 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 18 GHz 0.8 dB @ 4 GHz 1.0 dB @ 12.4 GHz 1.5 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x05 AS 122- K20 S3 a = 49.5 mm 32 dB @ DC to 4 GHz 26 dB @ 4 GHz to 18 GHz 20 dB 0.3 dB @ 4 GHz 0.5 dB @ 18 GHz 0.5 W x05 AS 122- K40 S3 a = 57.5 mm 32 dB @ DC to 4 GHz 26 dB @ 4 GHz to 18 GHz 40 dB 0.3 dB @ 4 GHz 0.5 dB @ 18 GHz 0.5 W a o15.7 RPC- N 50 , male - female xOrdering Number Remarks a SW20 RPC- 7 RPC- 7 xOrdering Number Remarks Return Loss Attenuation Tolerance x07 AP 122- P20 S3 32 dB @ DC to 4 GHz 26 dB @ 4 GHz to 18 GHz 20 dB 0.3 dB @ 4 GHz 0.5 W 0.5 dB @ 18 GHz x07 AP 122- P40 S3 32 dB @ DC to 4 GHz 23 dB @ 4 GHz to 18 GHz 40 dB 0.5 dB @ 4 GHz 0.5 W 1.0 dB @ 18 GHz Power Handling 41.5 o 22 xOrdering Number Remarks SW19 222 SW19 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.de Attenuators Test Devices RPC- 3.50, Stecker - Kuppler Return Loss x03 AS 102- K03 S3 a = 32.7 mm 26.4 dB @ DC to 4 GHz 3 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 26.5 GHz 0.5 dB @ 26.5 GHz 2 W @ 25 C to 0 W @ 125C x03 AS 102- K06 S3 a = 32.7 mm 26.4 dB @ DC to 4 GHz 6 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 26.5 GHz 0.5 dB @ 26.5 GHz 2 W @ 25 C to 0 W @ 125C x03 AS 102- K10 S3 a = 32.7 mm 26.4 dB @ DC to 4 GHz 10 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 26.5 GHz 0.5 dB @ 26.5 GHz 2 W @ 25 C to 0 W @ 125C x03 AS 102- K20 S3 a = 32.7 mm 26.4 dB @ DC to 4 GHz 20 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 26.5 GHz 0.5 dB @ 26.5 GHz 2 W @ 25 C to 0 W @ 125C x03 AS 102- K30 S3 a = 32.7 mm 26.4 dB @ DC to 4 GHz 30 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 26.5 GHz 0.7 dB @ 26.5 GHz 2 W @ 25 C to 0 W @ 125C x03 AS 102- K40 S3 a = 34.7 mm 26.4 dB @ DC to 4 GHz 40 dB 23.1 dB @ 4 GHz to 12.4 GHz 19.1 dB @ 12.4 GHz to 26.5 GHz 1.0 dB @ 26.5 GHz 2 W @ 25 C to 0 W @ 125C x03 AS 122- K20 S3 a = 32.7 mm 26.4 dB @ DC to 4 GHz 20.1 dB @ 4 GHz to 26.5 GHz 20 dB 0.3 dB @ 4 GHz 0.5 W 0.5 dB @ 26.5 GHz x03 AS 122- K40 S3 a = 34.7 mm 26.4 dB @ DC to 4 GHz 20.1 dB @ 4 GHz to 26.5 GHz 40 dB 0.4 dB @ 4 GHz 0.5 W 1.0 dB @ 26.5 GHz Attenuation Tolerance Power Handling a o9 RPC- 3.50, male - female xOrdering Number Remarks SW8 SW8 SW8 SMA, Stecker- Kuppler Return Loss x32 AS 102- K03 S3 a = 20 mm Tolerance Power Handling 23.1 dB @ DC to 4 GHz 3 dB 19.1 dB @ 4 GHz to 12.4 GHz 16.5 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.75 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x32 AS 102- K06 S3 a = 20 mm 23.1 dB @ DC to 4 GHz 6 dB 19.1 dB @ 4 GHz to 12.4 GHz 16.5 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.75 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x32 AS 102- K10 S3 a = 20 mm 23.1 dB @ DC to 4 GHz 10 dB 19.1 dB @ 4 GHz to 12.4 GHz 16.5 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.75 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x32 AS 102- K20 S3 a = 20 mm 23.1 dB @ DC to 4 GHz 20 dB 19.1 dB @ 4 GHz to 12.4 GHz 16.5 dB @ 12.4 GHz to 18 GHz 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 0.75 dB @ 18 GHz 2 W @ 25 C to 0 W @ 125C x32 AS 102- K30 S3 a = 20 mm 23.1 dB @ DC to 4 GHz 30 dB 19.1 dB @ 4 GHz to 12.4 GHz 16.5 dB @ 12.4 GHz to 18 GHz 0.5 dB @ 8 GHz 2 W @ 25 C to 0.75 dB @ 12.4 GHz 0 W @ 125C 1.5 dB @ 18 GHz x32 AS 102- K40 S3 a = 22 mm 23.1 dB @ DC to 4 GHz 40 dB 19.1 dB @ 4 GHz to 12.4 GHz 16.5 dB @ 12.4 GHz to 18 GHz 0.5 dB @ 8 GHz 1.0 dB @ 12.4 GHz 1.5 dB @ 18 GHz a SW7 SW8 2 W @ 25 C to 0 W @ 125C 12 Attenuation o8 SMA, male- female xOrdering Number Remarks Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.de 223 Test Devices Attenuators N 50 Standard, Stecker- Kuppler 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 2 W @ 25 C to 0 W @ 125C x53 AS 102- K03 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz 3 dB 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 2 W @ 25 C to 0 W @ 125C x53 AS 102- K06 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz 6 dB 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz 2 W @ 25 C to 0 W @ 125C x53 AS 102- K10 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz 10 dB 0.3 dB @ 8 GHz 0.6 dB @ 12.4 GHz 2 W @ 25 C to 0 W @ 125C x53 AS 102- K20 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz 20 dB 0.3 dB @ 4 GHz 0.6 dB @ 8 GHz 0.8 dB @ 12.4 GHz 2 W @ 25 C to 0 W @ 125C x53 AS 102- K30 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz 30 dB 0.3 dB @ 4 GHz 0.6 dB @ 8 GHz 1.0 dB @ 12.4 GHz 2 W @ 25 C to 0 W @ 125C x53 AS 105- K03 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 3 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125C x53 AS 105- K06 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 6 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125C x53 AS 105- K10 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 10 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125C x53 AS 105- K20 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 20 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.5 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125C x53 AS 105- K30 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 30 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.75 dB @ 10 GHz 5 W @ 25 C to 0 W @ 125C x53 AS 110- K03 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 3 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 10 W @ 25 C to 0 W @ 125C x53 AS 110- K06 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 6 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 10 W @ 25 C to 0 W @ 125C x53 AS 110- K10 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 10 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 10 W @ 25 C to 0 W @ 125C x53 AS 110- K20 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 20 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.5 dB @ 10 GHz 10 W @ 25 C to 0 W @ 125C x53 AS 110- K30 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 30 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.75 dB @ 10 GHz 10 W @ 25 C to 0 W @ 125C 224 o15.7 2 dB SW18 56.5 o20 x53 AS 102- K02 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz max. 49.5 SW18 67 51.5 2 W @ 25 C to 0 W @ 125C o15.7 Power Handling 0.3 dB @ 8 GHz 0.5 dB @ 12.4 GHz o21 Tolerance 1 dB o21 Attenuation x53 AS 102- K01 N3 26.4 dB @ DC to 4 GHz 20.8 dB @ 4 GHz to 10 GHz 19.1 dB @ 10 GHz to 12.4 GHz o21 N 50 Standard, male- female xOrdering Number Return Loss SW18 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.de Attenuators Test Devices Tolerance Power Handling 3 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125C x53 AS 120- K06 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 6 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125C x53 AS 120- K10 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 10 dB 0.3 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125C x53 AS 120- K20 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 20 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.5 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125C x53 AS 120- K30 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz 30 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.75 dB @ 10 GHz 20 W @ 25 C to 0 W @ 125C 93 o15.7 51 Attenuation x53 AS 120- K03 N3 26.4 dB @ DC to 2 GHz 21.2 dB @ 2 GHz to 5 GHz 14.0 dB @ 5 GHz to 10 GHz o21 xOrdering Number Return Loss SW18 BNC 50 , Stecker- Kuppler BNC 50 , male- female Attenuation Power Handling x51 AS 103- K03 N4 20.8 dB @ DC to 1.2 GHz 15.5 dB @ 1.2 GHz to 2 GHz 3 dB 0.4 dB 3 W @ 25 C to 0 W @ 125C x51 AS 103- K06 N4 20.8 dB @ DC to 1.2 GHz 15.5 dB @ 1.2 GHz to 2 GHz 6 dB 0.4 dB 3 W @ 25 C to 0 W @ 125C x51 AS 103- K10 N4 20.8 dB @ DC to 1.2 GHz 15.5 dB @ 1.2 GHz to 2 GHz 10 dB 0.4 dB 3 W @ 25 C to 0 W @ 125C x51 AS 103- K20 N4 20.8 dB @ DC to 1.2 GHz 15.5 dB @ 1.2 GHz to 2 GHz 20 dB 0.5 dB 3 W @ 25 C to 0 W @ 125C x51 AS 103- K30 N4 20.8 dB @ DC to 1.2 GHz 15.5 dB @ 1.2 GHz to 2 GHz 30 dB 1.0 dB 3 W @ 25 C to 0 W @ 125C x51 AS 103- K40 N4 20.8 dB @ DC to 1.2 GHz 15.5 dB @ 1.2 GHz to 2 GHz 40 dB 1.4 dB 3 W @ 25 C to 0 W @ 125C max. 49 12 xOrdering Number Return Loss Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.de 225 Test Devices Attenuators 7- 16, Stecker- Kuppler Tolerance Power Handling 3 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125C x60 AS 105- K06 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 6 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125C x60 AS 105- K10 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 10 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125C x60 AS 105- K20 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 20 dB 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125C x60 AS 105- K30 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 30 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125C x60 AS 105- K40 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 40 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.2 dB @ 8 GHz 5 W @ 25 C to 0 W @ 125C x60 AS 110- K03 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 3 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 10 W @ 25 C to 0 W @ 125C x60 AS 110- K06 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 6 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 10 W @ 25 C to 0 W @ 125C x60 AS 110- K10 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 10 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 10 W @ 25 C to 0 W @ 125C x60 AS 110- K20 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 20 dB 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 10 W @ 25 C to 0 W @ 125C x60 AS 110- K30 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 30 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 8 GHz 10 W @ 25 C to 0 W @ 125C x60 AS 110- K40 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 40 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.2 dB @ 8 GHz 10 W @ 25 C to 0 W @ 125C x60 AS 120- K03 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 3 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125C x60 AS 120- K06 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 6 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125C x60 AS 120- K10 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 10 dB 0.3 dB @ 2 GHz 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125C x60 AS 120- K20 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 20 dB 0.4 dB @ 4 GHz 0.8 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125C x60 AS 120- K30 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 30 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.0 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125C x60 AS 120- K40 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz 40 dB 0.4 dB @ 2 GHz 0.5 dB @ 4 GHz 1.2 dB @ 8 GHz 20 W @ 25 C to 0 W @ 125C 226 69 SW32 69 51 Attenuation x60 AS 105- K03 N1 30.7 dB @ DC to 1 GHz 26.4 dB @ 1 GHz to 2 GHz 20.0 dB @ 2 GHz to 8 GHz SW32 95 51 7- 16, male- female xOrdering Number Return Loss SW32 Rosenberger Hochfrequenztechnik GmbH & Co. KG, POB 1260, D- 84526 Tittmoning, Tel. +49- 86 84- 18- 0, Fax. +49- 86 84- 18- 499, www.rosenberger.de