35
G Series
RFI Power Line Filters
G Series
High Performance RFI Filters for Switching Power Supplies
1
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Maximum leakage current each Line to Ground:
EG Models VG Models
@ 120 VAC 60 Hz: .30 mA 1.2 mA
@250 VAC 50 Hz: .50 mA 2.0 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 6 & 10A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (T
a) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io= Ir(85-Ta)/45
Designed to provide excellent attenuation for
most digital electronics equipment
• Broad frequency range of performance from
20kHz to 30MHz
• Size and cost-effective solution
• Designed to help comply with EN55022 Level A
and FCC Part 15J Class B
Ordering Information
10 E G 1
Input / Output Style
1 – .250 [6.3] spade terminals
G Series
Leakage current designation
E – Low leakage (<0.5 mA)
V – Standard
Current Rating
6 or 10A
Specifications
Electrical Schematics
LINE LOAD
UL Recognized
CSA Certified
VDE Approved
6EG1 / 6VG1
Available Part Numbers
6EG1 6VG1
10EG1 10VG1
10EG1 / 10VG1
6EG1 & 6VG1
LINE LOAD
10EG1 & 10VG1
36
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
G Series
High Performance RFI Filters for Switching Power Supplies (continued)
Case Styles
A
B
C
D
E
Part No. ABCDE
   
 
6EG1/VG1     
    
10EG1/VG1     
    
Case Dimensions

 
 
 
Performance Data
Typical Insertion Loss
Minimum Insertion Loss
Common Mode / Asymmetrical (Line to Ground)
Common Mode / Asymmetrical (L-G)
Differential Mode / Symmetrical (L-L)
Measured in closed 50 Ohm system
6EG1
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
 
        

         
         

         
         
6VG1
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
10EG1
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
10VG1
db
100
90
80
70
60
50
40
30
20
10
00.01 0.1 1 10 30
Frequency in MHz
Differential Mode / Symmetrical (Line to Line)
 
        

        
        

       
        