GE Data Sheet JRCW016A0R Orca* Series; DC-DC Converter Power Modules 36-75 Vdc Input; 28Vdc Output; 16Adc Output RoHS Compliant Applications Features Compliant to RoHS II EU Directive 2011/65/EC (-Z versions) Compliant to REACH Directive (EC) No 1907/2006 High power density: 166 W/in3 Very high efficiency: >93.5% Typ at Full Load Industry standard half-brick pin-out Low output ripple and noise Industry standard, DOSA compliant half-brick footprint 57.7mm x 60.7mm x 12.7mm (2.27" x 2.39" x 0.5") Remote Sense 2:1 input voltage range Single tightly regulated output Constant switching frequency Constant Current Overcurrent limit Latch after short circuit fault shutdown RF Power Amplifier Over temperature protection auto restart Wireless Networks Output voltage adjustment trim, 14.0Vdc to 35.2Vdc Switching Networks Wide operating case temperature range (-40C to 100C) CE mark meets 2006/95/EC directives ANSI/UL# 60950-1, 2nd Ed. Recognized, CSA C22.2 No. 609501-07 Certified, and VDE 0805-1 (EN60950-1, 2nd Ed.) Licensed ISO** 9001 and ISO 14001 certified manufacturing facilities Compliant to IPC-9592A, Category 2, Class II Options Output OCP/OVP auto restart Shorter pins Unthreaded heatsink holes Tunable Loop* for transient response optimization Description The JRCW016A0R Orca series of dc-dc converters are a new generation of isolated, very high efficiency DC/DC power modules providing up to up to 16Adc output current at a nominal output voltage of 28Vdc in an industry standard, DOSA compliant halfbrick size footprint, which makes it an ideal choice for high voltage and high power applications. Threaded-through holes are provided to allow easy mounting or addition of a heatsink for high-temperature applications. The output is fully isolated from the input, allowing versatile polarity configurations and grounding connections. This module contains an optional new feature, the Tunable Loop, that allows the user to optimize the dynamic response of the converter to match the load with reduced amount of output capacitance, leading to savings on cost and PWB area. * Trademark of General Electric Company UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. VDE is a trademark of Verband Deutscher Elektrotechniker e.V. ** ISO is a registered trademark of the International Organization of Standards # March 23, 2016 (c)2016 General Electric Company. All rights reserved. Page 1 GE Data Sheet JRCW016A0R Orca Series; DC-DC Converter Power Modules 36-75 Vdc Input; 28.0Vdc Output; 16Adc Output Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability. Parameter Device Symbol Min Max Unit Input Voltage Continuous All VIN -0.3 80 Vdc Transient, operational (100 ms) All VIN,trans -0.3 100 Vdc Operating Ambient Temperature All Ta -40 85 C Operating Case Temperature (See Thermal Considerations section, Figure 17) All Tc -40 100 C Storage Temperature All Tstg -55 125 C Input to Case, Input to Output All 1500 Vdc Output to Case All 500 Vdc I/O Isolation Voltage (Current trip point=5mA): Electrical Specifications Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. Parameter Device Symbol Min Typ Max Unit All VIN 36 48 75 Vdc (VIN=36V to 75V, IO=IO, max) All IIN,max 14.0 Adc Inrush Transient All It 2 A2s Input Reflected Ripple Current, peak-to-peak (5Hz to 20MHz, 12H source impedance; VIN=0V to 75V, IO= IOmax ; see Figure 7) All Input Ripple Rejection (120Hz) All Operating Input Voltage (see Figure 12 for VIN MIN when using trim-up feature) Maximum Input Current 2 20 50 mAp-p dB CAUTION: This power module is not internally fused. An input line fuse must always be used. This power module can be used in a wide variety of applications, ranging from simple standalone operation to being an integrated part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. Always use an input line fuse, to achieve maximum safety and system protection. The safety agencies require a time-delay or fast-acting fuse with a maximum rating of 25 A in the ungrounded input connection (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturer's data sheet for further information. March 23, 2016 (c)2016 General Electric Company. All rights reserved. Page 2 GE Data Sheet JRCW016A0R Orca Series; DC-DC Converter Power Modules 36-75 Vdc Input; 28.0Vdc Output; 16Adc Output Electrical Specifications (continued) Parameter Device All Output Voltage Set-point (VIN=VIN,nom, IO=IO, max, Tc =25C) Output Voltage Set-Point Total Tolerance (Over all operating input voltage, resistive load, and temperature conditions until end of life) All Symbol Min Typ Max Unit VO, set 27.5 28 28.5 Vdc VO 27.0 29.0 Vdc Output Regulation Line (VIN=VIN, min to VIN, max) All 0.1 0.2 %Vo,set Load (IO=IO, min to IO, max) All 0.1 0.2 %Vo,set Temperature (Tc = -40C to +100C) All 0.25 0.5 %Vo,set All 45 55 mVrms All 80 200 mVpk-pk Output Ripple and Noise on nominal output (VIN=VIN, nom and IO=IO, min to IO, max) RMS (5Hz to 20MHz bandwidth) Peak-to-Peak (5Hz to 20MHz bandwidth) All, except -T -T CO 440 6500 F CO, 440 470 F With the Tunable Loop (ESR > 50 m)2 -T CO 440 10,000 F Output Power (Vo=28V to 35.2V) All PO,max 450 W Output Current All Io 0 16.0 Adc All IO, lim 17.0 All IO, sc All 93.0 fsw External Capacitance (ESR > 2.5 m)1 Without the Tunable Loop (ESRMAX = 80m)1 Output Current Limit Inception (Constant current until Vo