Absolute Maximum Ratings (Note)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales
Office/Distributors for availability and specifications.
Supply Voltage 7V
Input Voltage 7V
Operating Free Air Temperature Range
DM74LS 0§Ctoa
70§C
Storage Temperature Range b65§Ctoa
150§C
Note:
The ‘‘Absolute Maximum Ratings’’ are those values
beyond which the safety of the device cannot be guaran-
teed. The device should not be operated at these limits. The
parametric values defined in the ‘‘Electrical Characteristics’’
table are not guaranteed at the absolute maximum ratings.
The ‘‘Recommended Operating Conditions’’ table will define
the conditions for actual device operation.
Recommended Operating Conditions
Symbol Parameter DM74LS Units
Min Nom Max
VCC Supply Voltage 4.75 5 5.25 V
VIH High Level Input Voltage 2 V
VIL Low Level Input Voltage 0.8 V
IOH High Level Input Current b2.6 mA
IOL Low Level Output Current 24 mA
TAFree Air Operating Temperature 0 70 §C
Electrical Characteristics
Over recommended operating free air temperature range (unless otherwise noted)
Symbol Parameter Conditions Min Typ Max Units
(Note 1)
VIInput Clamp Voltage VCC eMin, IIeb
18 mA b1.5 V
VOH High Level Output VCC eMin, IOH eMax, 2.7 3.4 V
Voltage VIL eMax
VOL Low Level Output VCC eMin, IOL eMax, 0.35 0.5
Voltage VIH eMin V
IOL e4 mA, VCC eMin 0.25 0.4
IIInput Current @Max VCC eMax, VIe7V 1mA
Input Voltage
IIH High Level Input Current VCC eMax, VIe2.7V 20 mA
IIL Low Level Input Current VCC eMax, VIe0.4V b0.4 mA
IOS Short Circuit VCC eMax b30 b130 mA
Output Current (Note 2)
ICC Supply Current VCC eMax 50 mA
IOZH TRI-STATE Output VCC eVCCH 20 mA
off Current High VOZH e2.7V
IOZL TRI-STATE Output VCC eVCCH b20 mA
off Current Low VOZL e0.4V
Note 1: All typicals are at VCC e5V, TAe25§C.
Note 2: Not more than one output should be shorted at a time, and the duration should not exceed one second.
2