TRG150A S E R I E S 150W SWITCHING ADAPTER WITH PFC TUVRheinlandTUVRheinland Group Group TUVRheinland Group C C C USUSUS E176177 E176177 E176177 PS E Features * Universal Input Range: 90-264VAC * Meet CEC & ErP Level V * Active PFC Meets EN61000-3-2 (Output Cable Length 1800mm) * Conductive EMI Meets CISPR/FCC (TRG150A120: Output Cable Length 950mm) Class B (TRG150A150~190: Output Cable Length 1220mm) * Continuous Short Circuit Protection (TRG150A240~480: Output Cable Length 1800mm) * Over Voltage Protection Ordering information TRG150AXXX - XX X XX Model No. DC Plug Type OVP DC Cable Length and Type * Please see Page 243 for E: With OVP 471:950mm with Ferrite Core more detailed descriptions 510:950mm with Ferrite Core 12: 1220mm with Ferrite Core 13: 1800mm with Ferrite Core *471: 18AWG/UL2464 510&12&13: 16AWG/UL2464 MODEL 225 OUTPUT VOLTAGE MIN. LOAD CURRENT RIPPLE & NOISE VOLTAGE SETPOINT OUTPUT LINE LOAD REGULATION REGULATION %EFF. (Typ.) TRG150A120 12 V 0A 12.50 A 2% 2.5% 1% 5% 87% TRG150A150 15 V 0A 10.00 A 2% 2.5% 1% 5% 87% TRG150A180 18 V 0A 8.34 A 2% 2.5% 1% 5% 87% TRG150A190 19 V 0A 7.90 A 2% 2.5% 1% 5% 87% TRG150A240 24 V 0A 6.25 A 2% 2.5% 1% 5% 87% TRG150A280 28 V 0A 5.36 A 2% 2.5% 1% 5% 87% TRG150A300 30 V 0A 5.00 A 2% 2.5% 1% 5% 87% TRG150A360 36 V 0A 4.17 A 2% 2.5% 1% 5% 87% TRG150A480 48 V 0A 3.13 A 2% 2.5% 1% 5% 87% Specifications are subject to change without notice. Rated Load(%) 100% Specifications 75% 20LFM(Natural Convection) 50% 25% TRG150A Series Derating Curve 0% 0 INPUT SPECIFICATIONS: 5 10 15 20 25 30 35 40 45 Ambient Temperature(C) Voltage .................................................................................... 90~264Vac Frequency ....................................................................... 47 to 63Hz Inrush Current ...................................................... 120A max. @240Vac Conducted EMI ................................................... CISPR/FCC Class B Leakage Current ............................................................. 3.5mA max. Rated Load(%) 100% 50 55 60 65 75% 20LFM(Natural Convection) 50% 25% 0% 0 5 10 15 20 25 30 35 40 45 Ambient Temperature(C) 50 55 60 65 OUTPUT SPECIFICATIONS: Holdup Time .......................................................... 8ms typ. @115Vac Short Circuit Protection ................................................... Continuous Over Voltage Protection ............................................................ Yes 100% 90% Isolation ................................................. Input to output = 4,242VDC Operating Temperature ............ 0C~65C,40~65C with 2%/C Derating Storage Temperature ............................................................ -20~85C Cooling ............................................................ Natural Convection Switching Frequency ................................................... 67KHz Typical Dimensions ............. 7.087x2.913x1.614 inches (180.00x74.00x41.00 mm) Weight ................................................................... 950g (2.1Pounds) AC Inlet ......................................................................... IEC320/C14 SAFETY AND EMC: Emission and lmmunity ................. EN55022 Class B, FCC Part 15 Class B EN61000-3-2,EN61000-3-3, EN55024 EN61204-3 Safety ............................................... IEC60950-1, EN60950-1, UL60950-1 70% 60% Low Voltage Wattage Drating Curve 50% 40% 100% 30% 90% 90 80% Load(%) GENERAL SPECIFICATIONS: Load(%) 80% 110 130 150 170 190 Input Volatge(VAC) 210 230 250 260 T R G 1 5 0 A Low Voltage Wattage Drating Curve 70% NOTE:60% 1. Voltage 50% setpoint at 60% full load. 2. Add a 0.1F ceramic capacitor and a 47F E.L. capacitor to output 40% for Ripple & Noise measurement @20MHz BW. 3. Line 30% regulation measured from 100Vac to 240Vac with full load. 90 110 measured 130 150 170 to190 210 load 230 250 260 4. Load regulation from 60% 100% full and from 60% Input to 20% full load (60% +/- 40% full Volatge(VAC) load). 5. "Various TRG Series adapters are PSE certified. PSE certification alone is not sufficient for importation into Japan. A valid PSE mark must contain the name of the importer as shown in the example below. If PSE mark is required, the name of the registered importer must be supplied to Cincon on order placement. Product labels will not contain PSE mark if importer name is not supplied. Consult factory or local representative for details". PS IMPORTER NAME E JET INPUT OUTPUT AU100-240V, 0.5A 33-44VA, 50-60Hz DC 5V, 2A Mechanical Specification All Dimensions In Inches(mm) Tolerance Inches: x.xxx= 0.02 Millimeters: x.xx= 0.5 70.866 (1800.00)1.969 (50.00) 2.913 (74.00) 7.087 (180.00) DC Plug type: V+ -- )-- VDC Plug:Right Angle(o5.5/o2.5) L12mm 16AWG / 1800mm 0.138 (3.50) 1.614 (41.00) IEC320/C14 Typical at 25C, nominal line and 60% load, unless otherwise Specified 226