GSP1 AC Inlet for Screw-on PCB Mounting
Basic Specification
GSP 1 = Right-angle AC inlet for pcb mounting
GSP 1 . X X X X . X
GSP 1 . 2315 . 1
Black housing
Protection class I, solder/quick-connect ground terminal
6.3x0.8mm, 90˚ to connector axis
Right-angle appliance connector for pcb mounting
Black insulation cover, mounted
PCB side of mounting flange has pre-inserted nut, front side has holes for M3
screws
9.05 / 7.3 mm terminal spacing
Ground Terminal
0* = Protection class II, without ground
1* = Protection class I, ground terminal is solder
quick connect 4.8x0.8mm, 90˚ to conn. axis
2 = Same as 1, but ground terminal is not
connected with pcb
3* = Protection class I, ground terminal is solder
quick connect 4.8x0.8mm in connector axis
4 = Same as 3, but ground terminal is not
connected to pcb
5 = Protection class I, ground terminal is solder/
quick-connect 6.3x0.8mm, 90˚ to conn. axis
6 = Same as 5, but ground terminal is not
connected to pcb
7 = Protection class I, ground terminal is solder/
quick-connect 6.3x0.8mm in connector axis
8 = Same as 7, but ground terminal is not
connected to pcb
Insulation Cover
0* = Without insulation cover
1* = Black insulation cover, mounted **
2 = Black insulation cover included (separate) **
Mounting Flange
1* = Holes for cylindric M3 screws
2* = With 4 pre-inserted nuts
3 = PCB side with pre-inserted nut, front side with holes
for M3 screws
4 = PCB side with holes for M3 screws, front side with
pre-inserted nuts
5* = With holes for self-tapping 3mm screws (4 included)
6 = With holes for self-tapping 3mm screws (2 included)
7 = Mount with self-tapping 3mm screws (not incl.)
Terminal Spacing 1)
6 = 7 / 9.7 mm
7 = 9.05 / 7.3 mm
8*= 9.05 / 9.7 mm
9*= 7 / 7.3 mm
For “cold” connections 70˚C, Protection Class I or II
Right-angle pcb mount with flange for
— M3 screws
— self-tapping 3mm screws
— pre-inserted nuts for M3 screws
Ground terminal is solder / quick-connect in 4.8 x 0.8mm
or 6.3 x 0.8mm
Ground terminal is positioned for access from the top or
back of the connector
Optional insulation cover for protection against electrical contact
Material: temperature resistant thermoplastic UL 94V-O
Terminals: brass, tin and nickel-plated
UL recognition 15A/250V File #E96454
CSA certification 15A/250V File #LR38456
VDE approval 10A/250V File #73753
SEMKO approval 10A/250V
SEV approval 10A/250V
Color of Housing
1* = Black
2 = Grey
File
numbers
on request
Order Numbers: Standards: EN60320;
IEC 320 / C14 / C18
without with
insulation cover insulation cover
x = 31.45 (4.8 x 0.8)
32.45 (6.3 x 0.8)
y = 14.25 (4.8 x 0.8)
15.25 (6.3 x 0.8)
3
2
1
4
pos. 1, 2, 5, 6
pos. 3, 4, 7, 8
delete for protection class II
Pin spacings Ground terminals
R 5.9 max.
30.3+0.2
0
22.5
40 ±0.15
3.6
X
y
40 ±0.15
40 ±0.15
40 ±0.15
40 ±0.15
3.6 3.63.6
3.6
9.7 ±0.1 9.7 ±0.1
7.3 ±0.1
7.3 ±0.1
7 ±0.05 7 ±0.05
9.05+0.1
- 0.2 9.05+0.1
- 0.2
9.05 - 0.2 9.05+0.1
- 0.2
+0.1
7 ±0.05 7 ±0.05
1.6
1.6
1.6
1.6
2.4 ±0.1
+0.1
0
Ø 3.4
8.7 ±0.05
Ø 3.4 +0.1
0
15.85 ±0.1
27.8
3.5 ±0.5
49.6
40 ±0.15
29.9 ±0.1
21.9 ±0.1
R 6
24.3 25.5
22
15.85 ±0.1
8.7 ±0.05
+0.2
0
mounting
cut-out
3.5
Former version Improved version
GSP1.1xxx.x GSP1.6xxx.x
GSP1.2xxx.x GSP1.7xxx.x
GSP1.3xxx.x GSP1.8xxx.x
GSP1.4xxx.x GSP1.9xxx.x
Robust pins for easy pcb
mounting
Schurter recommends the use
of the improved, robust pin
version for existing applications
and new designs. The former
version will still be available,
but will no longer be shown in
the catalog.
* standard configuration. Contact Schurter, Inc. for non-standard configuration order minimums.
** For additional insulation cover (spare part only), use order number 0853.0804
1) See notes above regarding part number change for improved, robust pins
Ordering example: