General Purpose Low Power PCB Relays SCHRACK Power PCB Relay RT2 DC and AC (for global markets) n n n n n n 2 pole 8A, 2 form C (CO) or 2 form A (NO) contacts DC or AC coil 5kV/10mm coil-contact, reinforced insulation Ambient temperature up to 85C WG version: product in accordance to IEC60335-1 Reflow version: for THR (Through-Hole Reflow) soldering process Typical applications Boiler control, timers, garage door control, POS automation, interface modules. Zb Contact Data (continued) Approvals Mechanical endurance DC coil DC coil, reflow version AC coil AC coil, reflow version VDE Cert. No. 40007571, UL E214025, cCSAus 1142018 Technical data of approved types on request. Contact Data Contact arrangement 2 form C (CO) or 2 form A (NO) Rated voltage 250VAC Max. switching voltage 400VAC Rated current 8A, UL: 10A Limiting continuous current 8A, UL: 10A Limiting making current, max. 4s, duty factor 10% 15A Breaking capacity max. 2000VA Contact materialAgNi 90/10, AgNi 90/10 gold plated, AgSnO2 Frequency of operation, with/without load DC coil 360/72000h-1 AC coil 360/36000h-1 Operate/release time max., DC coil 8/6ms Bounce time max., DC coil, form A/form B 4/10ms Electrical endurance see electrical endurance graph1) Contact ratings Type Contact IEC 61810 RT424 DC coil C (CO) RT444 AC coil A (NO) RT424 AC coil C (CO) UL 508 RT424 DC coil A/B (NO/NC) RT424 DC coil A/B (NO/NC) RT424 DC coil A/B (NO/NC) EN60947-5-1 RTE24 DC coil A/B (NO/NC) RTE24 DC coil A/B (NO/NC) RTE24 DC coil A/B (NO/NC) EN60730-1 RT424 DC coil A/B (NO/NC) Load Cycles 8A, 250VAC, cos=1, 85C 8A, 250VAC, cos=1, 70C 8A, 250VAC, cos=1, 70C 10x103 50x103 30x103 10A, 250VAC, gen. purpose, 85C 1/2hp, 240VAC, 85C Pilot duty, B300, R300, 85C 20x103 1x103 6x103 AC15, 250VAC, 3A DC13, 24VDC, 2A DC13, 250VDC, 0.2A 6.050 6.050 6.050 6(2)A, 250VAC, 85C 100x103 1) For reflow solderable versions: actual contact performance may be influenced by the reflow soldering process. 10-2014, Rev. 1014 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. >30x106 operations >10x106 operations >5x106 operations >2x106 operations Coil Data Coil voltage range, DC coil/AC coil 5 to 110VDC / 24 to 230VAC Operative range, IEC 61810 2 Coil insulation system according UL class F Coil versions, DC coil Coil Rated Operate code voltage voltage VDC VDC 005 5 3.5 006 6 4.2 009 9 6.3 012 12 8.4 024 24 16.8 048 48 33.6 060 60 42.0 110 110 77.0 Release voltage VDC 0.5 0.6 0.9 1.2 2.4 4.8 6.0 11.0 Coil resistance 10%2) 62 90 200 360 1440 5520 85702) 288002) Rated coil power mW 403 400 400 400 400 417 420 420 2) Coil resistance 12%. All figures are given for coil without pre-energization, at ambient temperature +23C. Other coil voltages on request. Coil versions, AC coil 50Hz Coil Rated Operate code voltage voltage VAC VAC 524 24 18.0 615 115 86.3 620 120 90.0 700 200 150.0 730 230 172.5 Release voltage VAC 3.6 17.3 18.0 30.0 34.5 Coil resistance 15%3) 3503) 8100 8800 24350 32500 Rated coil power VA 0.76 0.76 0.75 0.76 0.74 3) Coil resistance 10%. All figures are given for coil without pre-energization, at ambient temperature +23C, 50Hz. Other coil voltages on request. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. 1 General Purpose Low Power PCB Relays SCHRACK Power PCB Relay RT2 DC and AC (for global markets) (Continued) Insulation Data Initial dielectric strength between open contacts between contact and coil between adjacent contacts Clearance/creepage between contact and coil between adjacent contacts Material group of insulation parts Tracking index of relay base reflow version 1000Vrms 5000Vrms 2500Vrms 10/10mm 3/4mm IIIa PTI 250V PTI 175V Other Data Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content refer to the Product Compliance Support Center at www.te.com/customersupport/rohssupportcenter Resistance to heat and fire WG version or reflow version according EN60335, par30 Ambient temperature DC coil -40 to 85C AC coil -40 to 70C AgSnO2 contacts -40 to 70C Category of environmental protection, IEC 61810 standard version RTII - flux proof, RTIII - wash tight reflow version RTII - flux proof Vibration resistance (functional), form A/form B contact, 30 to 300Hz 20g/5g Shock resistance (destructive) 100g Other Data (continued) Terminal type PCB-THT, plug-in reflow version PCB-THR Mounting distance, AC coil 2.5mm Weight13g Resistance to soldering heat THT, IEC 60068-2-20 RTII 270C/10s RTIII 260C/5s Resistance to soldering heat THR reflow soldering (for reflow version) forced gas convection 4) or vapour phase 5) temperature profile according EN61730 Packaging/unit tube/20pcs., box/500pcs. 4) infrared heating not allowed. 5) recommended fluid LS/230. Accessories For details see datasheet Accessories Industrial Power Relay RT NOTE: indicated contact ratings and electrical endurance data for direct wiring of relays (according IEC 61810-1); for relays mounted on sockets deratings may apply. Dimensions PCB layout / terminal assignment THT version THR version (reflow solderable) Bottom view on solder pins *) With the recommended PCB hole sizes a grid pattern from 2.5mm to 2.54mm can be used. 2 form C (CO) contacts Process conditions for Reflow soldering according to EN61760-1 2 form A (NO) contacts 2 10-2014, Rev. 1014 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. General Purpose Low Power PCB Relays SCHRACK Power PCB Relay RT2 DC and AC (for global markets) (Continued) Product code structure Typical product code Type RT 4 2 4 024 RT Power PCB Relay RT2 Version 4 8A, pinning 5mm, flux proof E 8A, pinning 5mm, wash tight (not for Reflow version) Contact arrangement 2 2 form C (CO) contacts 4 2 form A (NO) contacts Contact material 3 AgSnO 4 AgNi 90/10 5 AgNi 90/10 gold plated Coil Coil code: please refer to coil versions table Version Blank Standard version WG Product in accordance with IEC 60335-1 (domestic appliances) R Reflow solderable Product code Version Contacts Contact material Coil Version Part number RT423730 8A, 2 form C (CO) AgSnO 230VAC Standard 4-1393243-3 RT424005 pinning 5mm, contacts AgNi 90/10 5VDC 5-1393243-9 RT424006 flux proof 6VDC 6-1393243-1 RT424012 12VDC 6-1393243-3 RT424012WG IEC60335-1 compliant 7-1415538-8 RT424024 24VDC Standard 6-1393243-8 RT424024WG IEC60335-1 compliant 7-1415538-7 RT424048 48VDC Standard 7-1393243-0 RT424060 60VDC 7-1393243-3 RT424110 110VDC 7-1393243-5 RT424524 24VAC 7-1393243-6 RT424615 115VAC 7-1393243-8 RT424730 230VAC 7-1393243-9 RT425003 AgNi 90/10 3VDC 7-1415525-1 RT425005 gold plated 5VDC 8-1393243-0 RT425012 12VDC 8-1393243-2 RT425024 24VDC 8-1393243-5 RT444012 2 form A (NO) AgNi 90/10 12VDC 9-1393243-7 RT444024contacts 24VDC 9-1393243-9 RTE24005 8A, 2 form C (CO) 5VDC 1393243-1 RTE24006 pinning 5mm, contacts 6VDC 1393243-2 RTE24012 wash tight 12VDC 1393243-4 RTE24024 24VDC 1-1393243-0 RTE24048 48VDC 1-1393243-1 RTE24110 110VDC 1-1393243-4 RTE24524 24VAC 1-1393243-5 RTE24615 115VAC 1-1393243-7 RTE24730 230VAC 1-1393243-8 RTE25005 AgNi 90/10 5VDC 1-1393243-9 RTE25012 gold plated 12VDC 2-1393243-0 RTE25024 24VDC 2-1393243-1 RTE25524 2-1393243-4 RTE43009 2 form A (NO) AgSnO 9VDC 4-1415535-1 RTE44009 contacts AgNi 90/10 3-1393243-1 RTE44730 230VAC 3-1393243-5 This list represents the most common types and does not show all variants covered by this datasheet. Other types on request. 10-2014, Rev. 1014 www.te.com (c) 2014 Tyco Electronics Corporation, a TE Connectivity Ltd. company. Catalog and product specification according to IEC 61810-1 and to be used only together with the `Definitions' section. Catalog and product data is subject to the terms of the disclaimer and all chapters of the `Definitions' section, available at http://relays.te.com/definitions Catalog product data, `Definitions' section, application notes and all specifications are subject to change. 3