FLEX 6000 Programmable Logic Device Family (R) March 2001, ver. 4.1 Features... Data Sheet Provides an ideal low-cost, programmable alternative to highvolume gate array applications and allows fast design changes during prototyping or design testing Product features - Register-rich, look-up table- (LUT-) based architecture - OptiFLEX(R) architecture that increases device area efficiency - Typical gates ranging from 5,000 to 24,000 gates (see Table 1) - Built-in low-skew clock distribution tree - 100% functional testing of all devices; test vectors or scan chains are not required System-level features - In-circuit reconfigurability (ICR) via external configuration device or intelligent controller - 5.0-V devices are fully compliant with peripheral component interconnect Special Interest Group (PCI SIG) PCI Local Bus Specification, Revision 2.2 - Built-in Joint Test Action Group (JTAG) boundary-scan test (BST) circuitry compliant with IEEE Std. 1149.1-1990, available without consuming additional device logic - MultiVoltTM I/O interface operation, allowing a device to bridge between systems operating at different voltages - Low power consumption (typical specification less than 0.5 mA in standby mode) - 3.3-V devices support hot-socketing Table 1. FLEX 6000 Device Features Feature Typical gates (1) EPF6010A EPF6016 EPF6016A EPF6024A 10,000 16,000 16,000 24,000 Logic elements (LEs) 880 1,320 1,320 1,960 Maximum I/O pins 102 204 171 218 3.3 V 5.0 V 3.3 V 3.3 V Supply voltage (VCCINT) Note: (1) The embedded IEEE Std. 1149.1 JTAG circuitry adds up to 14,000 gates in addition to the listed typical gates. Altera Corporation A-DS-F6000-04.1 1 FLEX 6000 Programmable Logic Device Family Data Sheet ...and More Features Powerful I/O pins - Individual tri-state output enable control for each pin - Programmable output slew-rate control to reduce switching noise - Fast path from register to I/O pin for fast clock-to-output time Flexible interconnect - FastTrack(R) Interconnect continuous routing structure for fast, predictable interconnect delays - Dedicated carry chain that implements arithmetic functions such as fast adders, counters, and comparators (automatically used by software tools and megafunctions) - Dedicated cascade chain that implements high-speed, high-fanin logic functions (automatically used by software tools and megafunctions) - Tri-state emulation that implements internal tri-state networks - Four low-skew global paths for clock, clear, preset, or logic signals Software design support and automatic place-and-route provided by Altera's development system for Windows-based PCs, Sun SPARCstations, and HP 9000 Series 700/800 Flexible package options - Available in a variety of packages with 100 to 256 pins, including the innovative FineLine BGATM packages (see Table 2) - SameFrameTM pin-compatibility (with other FLEX(R) 6000 devices) across device densities and pin counts - Thin quad flat pack (TQFP), plastic quad flat pack (PQFP), and ball-grid array (BGA) packages (see Table 2) - Footprint- and pin-compatibility with other FLEX 6000 devices in the same package Additional design entry and simulation support provided by EDIF 2 0 0 and 3 0 0 netlist files, the library of parameterized modules (LPM), Verilog HDL, VHDL, DesignWare components, and other interfaces to popular EDA tools from manufacturers such as Cadence, Exemplar Logic, Mentor Graphics, OrCAD, Synopsys, Synplicity, VeriBest, and Viewlogic Table 2. FLEX 6000 Package Options & I/O Pin Count Device 100-Pin TQFP EPF6010A 71 100-Pin FineLine BGA EPF6024A 2 81 208-Pin PQFP 240-Pin PQFP 256-Pin BGA 117 171 199 204 117 171 117 171 199 218 256-pin FineLine BGA 102 EPF6016 EPF6016A 144-Pin TQFP 81 171 219 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet General Description The Altera(R) FLEX 6000 programmable logic device (PLD) family provides a low-cost alternative to high-volume gate array designs. FLEX 6000 devices are based on the OptiFLEX architecture, which minimizes die size while maintaining high performance and routability. The devices have reconfigurable SRAM elements, which give designers the flexibility to quickly change their designs during prototyping and design testing. Designers can also change functionality during operation via in-circuit reconfiguration. FLEX 6000 devices are reprogrammable, and they are 100% tested prior to shipment. As a result, designers are not required to generate test vectors for fault coverage purposes, allowing them to focus on simulation and design verification. In addition, the designer does not need to manage inventories of different gate array designs. FLEX 6000 devices are configured on the board for the specific functionality required. Table 3 shows FLEX 6000 performance for some common designs. All performance values shown were obtained using Synopsys DesignWare or LPM functions. Special design techniques are not required to implement the applications; the designer simply infers or instantiates a function in a Verilog HDL, VHDL, Altera Hardware Description Language (AHDL), or schematic design file. Table 3. FLEX 6000 Device Performance for Common Designs Application LEs Used Performance -1 Speed Grade -2 Speed Grade Units -3 Speed Grade 16-bit loadable counter 16 172 153 133 MHz 16-bit accumulator 16 172 153 133 MHz 24-bit accumulator 24 136 123 108 MHz 16-to-1 multiplexer (pin-to-pin) (1) 10 12.1 13.4 16.6 ns 16 x 16 multiplier with a 4-stage pipeline 592 84 67 58 MHz Note: (1) This performance value is measured as a pin-to-pin delay. Altera Corporation 3 FLEX 6000 Programmable Logic Device Family Data Sheet Table 4 shows FLEX 6000 performance for more complex designs. Table 4. FLEX 6000 Device Performance for Complex Designs Application Note (1) LEs Used Performance Units -1 Speed Grade -2 Speed Grade -3 Speed Grade 8-bit, 16-tap parallel finite impulse response (FIR) filter 599 94 80 72 MSPS 8-bit, 512-point fast Fourier transform (FFT) function 1,182 75 63 89 53 109 43 S MHz a16450 universal asynchronous receiver/transmitter (UART) 487 36 30 25 MHz PCI bus target with zero wait states 609 56 49 42 MHz Note: (1) The applications in this table were created using Altera MegaCoreTM functions. FLEX 6000 devices are supported by Altera development systems; a single, integrated package that offers schematic, text (including AHDL), and waveform design entry, compilation and logic synthesis, full simulation and worst-case timing analysis, and device configuration. The Altera software provides EDIF 2 0 0 and 3 0 0, LPM, VHDL, Verilog HDL, and other interfaces for additional design entry and simulation support from other industry-standard PC- and UNIX workstation-based EDA tools. The Altera software works easily with common gate array EDA tools for synthesis and simulation. For example, the Altera software can generate Verilog HDL files for simulation with tools such as Cadence Verilog-XL. Additionally, the Altera software contains EDA libraries that use devicespecific features such as carry chains which are used for fast counter and arithmetic functions. For instance, the Synopsys Design Compiler library supplied with the Altera development systems include DesignWare functions that are optimized for the FLEX 6000 architecture. The Altera development system runs on Windows-based PCs, Sun SPARCstations, and HP 9000 Series 700/800. f 4 See the MAX+PLUS II Programmable Logic Development System & Software Data Sheet and the Quartus Programmable Logic Development System & Software Data Sheet for more information. Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Functional Description The FLEX 6000 OptiFLEX architecture consists of logic elements (LEs). Each LE includes a 4-input look-up table (LUT), which can implement any 4-input function, a register, and dedicated paths for carry and cascade chain functions. Because each LE contains a register, a design can be easily pipelined without consuming more LEs. The specified gate count for FLEX 6000 devices includes all LUTs and registers. LEs are combined into groups called logic array blocks (LABs); each LAB contains 10 LEs. The Altera software automatically places related LEs into the same LAB, minimizing the number of required interconnects. Each LAB can implement a medium-sized block of logic, such as a counter or multiplexer. Signal interconnections within FLEX 6000 devices--and to and from device pins--are provided via the routing structure of the FastTrack Interconnect. The routing structure is a series of fast, continuous row and column channels that run the entire length and width of the device. Any LE or pin can feed or be fed by any other LE or pin via the FastTrack Interconnect. See "FastTrack Interconnect" on page 17 of this data sheet for more information. Each I/O pin is fed by an I/O element (IOE) located at the end of each row and column of the FastTrack Interconnect. Each IOE contains a bidirectional I/O buffer. Each IOE is placed next to an LAB, where it can be driven by the local interconnect of that LAB. This feature allows fast clock-to-output times of less than 8 ns when a pin is driven by any of the 10 LEs in the adjacent LAB. Also, any LE can drive any pin via the row and column interconnect. I/O pins can drive the LE registers via the row and column interconnect, providing setup times as low as 2 ns and hold times of 0 ns. IOEs provide a variety of features, such as JTAG BST support, slew-rate control, and tri-state buffers. Figure 1 shows a block diagram of the FLEX 6000 OptiFLEX architecture. Each group of ten LEs is combined into an LAB, and the LABs are arranged into rows and columns. The LABs are interconnected by the FastTrack Interconnect. IOEs are located at the end of each FastTrack Interconnect row and column. Altera Corporation 5 FLEX 6000 Programmable Logic Device Family Data Sheet Figure 1. OptiFLEX Architecture Block Diagram IOEs Row FastTrack Interconnect Row FastTrack Interconnect IOEs Column FastTrack Interconnect Column FastTrack Interconnect Local Interconnect (Each LAB accesses two local interconnect areas.) Logic Elements FLEX 6000 devices provide four dedicated, global inputs that drive the control inputs of the flipflops to ensure efficient distribution of highspeed, low-skew control signals. These inputs use dedicated routing channels that provide shorter delays and lower skews than the FastTrack Interconnect. These inputs can also be driven by internal logic, providing an ideal solution for a clock divider or an internally generated asynchronous clear signal that clears many registers in the device. The dedicated global routing structure is built into the device, eliminating the need to create a clock tree. Logic Array Block An LAB consists of ten LEs, their associated carry and cascade chains, the LAB control signals, and the LAB local interconnect. The LAB provides the coarse-grained structure of the FLEX 6000 architecture, and facilitates efficient routing with optimum device utilization and high performance. 6 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet The interleaved LAB structure--an innovative feature of the FLEX 6000 architecture--allows each LAB to drive two local interconnects. This feature minimizes the use of the FastTrack Interconnect, providing higher performance. An LAB can drive 20 LEs in adjacent LABs via the local interconnect, which maximizes fitting flexibility while minimizing die size. See Figure 2. Figure 2. Logic Array Block Row Interconnect The row interconnect is bidirectionally connected to the local interconnect. LEs can directly drive the row and column interconnect. To/From Adjacent LAB or IOEs Local Interconnect To/From Adjacent LAB or IOEs The 10 LEs in the LAB are driven by two local interconnect areas. The LAB can drive two local interconnect areas. Column Interconnect In most designs, the registers only use global clock and clear signals. However, in some cases, other clock or asynchronous clear signals are needed. In addition, counters may also have synchronous clear or load signals. In a design that uses non-global clock and clear signals, inputs from the first LE in an LAB are re-routed to drive the control signals for that LAB. See Figure 3. Altera Corporation 7 FLEX 6000 Programmable Logic Device Family Data Sheet Figure 3. LAB Control Signals The dedicated input signals can drive the clock and asynchronous clear signals. 4 Dedicated Inputs Input signals to the first LE in an LAB (i.e., LE 1) can be rerouted to drive control signals within the LAB. LE 1 LABCTRL1/ SYNCLR LABCTRL2 CLK1/SYNLOAD CLK2 LAB-wide control signals (SYNCLR and SYNLOAD signals are used in counter mode). Logic Element An LE, the smallest unit of logic in the FLEX 6000 architecture, has a compact size that provides efficient logic usage. Each LE contains a fourinput LUT, which is a function generator that can quickly implement any function of four variables. An LE contains a programmable flipflop, carry and cascade chains. Additionally, each LE drives both the local and the FastTrack Interconnect. See Figure 4. 8 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 4. Logic Element data1 data2 data3 data4 Look-Up Table (LUT) Carry-In Cascade-In Carry Chain Cascade Chain Register Bypass Programmable Register PRN Q LE-Out D CLRN labctrl1 labctrl2 Chip-Wide Reset Clear/ Preset Logic Clock Select labctrl3 labctrl4 Carry-Out Cascade-Out The programmable flipflop in the LE can be configured for D, T, JK, or SR operation. The clock and clear control signals on the flipflop can be driven by global signals, general-purpose I/O pins, or any internal logic. For combinatorial functions, the flipflop is bypassed and the output of the LUT drives the outputs of the LE. The LE output can drive both the local interconnect and the FastTrack Interconnect. The FLEX 6000 architecture provides two types of dedicated high-speed data paths that connect adjacent LEs without using local interconnect paths: carry chains and cascade chains. A carry chain supports high-speed arithmetic functions such as counters and adders, while a cascade chain implements wide-input functions such as equivalent comparators with minimum delay. Carry and cascade chains connect LEs 2 through 10 in an LAB and all LABs in the same half of the row. Because extensive use of carry and cascade chains can reduce routing flexibility, these chains should be limited to speed-critical portions of a design. Altera Corporation 9 FLEX 6000 Programmable Logic Device Family Data Sheet Carry Chain The carry chain provides a very fast (0.1 ns) carry-forward function between LEs. The carry-in signal from a lower-order bit drives forward into the higher-order bit via the carry chain, and feeds into both the LUT and the next portion of the carry chain. This feature allows the FLEX 6000 architecture to implement high-speed counters, adders, and comparators of arbitrary width. Carry chain logic can be created automatically by the Altera software during design processing, or manually by the designer during design entry. Parameterized functions such as LPM and DesignWare functions automatically take advantage of carry chains for the appropriate functions. Because the first LE of each LAB can generate control signals for that LAB, the first LE in each LAB is not included in carry chains. In addition, the inputs of the first LE in each LAB may be used to generate synchronous clear and load enable signals for counters implemented with carry chains. Carry chains longer than nine LEs are implemented automatically by linking LABs together. For enhanced fitting, a long carry chain skips alternate LABs in a row. A carry chain longer than one LAB skips either from an even-numbered LAB to another even-numbered LAB, or from an odd-numbered LAB to another odd-numbered LAB. For example, the last LE of the first LAB in a row carries to the second LE of the third LAB in the row. In addition, the carry chain does not cross the middle of the row. For instance, in the EPF6016 device, the carry chain stops at the 11th LAB in a row and a new carry chain begins at the 12th LAB. Figure 5 shows how an n-bit full adder can be implemented in n + 1 LEs with the carry chain. One portion of the LUT generates the sum of two bits using the input signals and the carry-in signal; the sum is routed to the output of the LE. Although the register can be bypassed for simple adders, it can be used for an accumulator function. Another portion of the LUT and the carry chain logic generates the carry-out signal, which is routed directly to the carry-in signal of the next-higher-order bit. The final carry-out signal is routed to an LE, where it is driven onto the FastTrack Interconnect. 10 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 5. Carry Chain Operation Carry-In a1 LUT s1 Register b1 Carry Chain LE 2 a2 LUT Register s2 b2 Carry Chain LE 3 an LUT Register sn bn Carry Chain LE n + 1 LUT Register Carry-Out Carry Chain LE n + 2 Altera Corporation 11 FLEX 6000 Programmable Logic Device Family Data Sheet Cascade Chain The cascade chain enables the FLEX 6000 architecture to implement very wide fan-in functions. Adjacent LUTs can be used to implement portions of the function in parallel; the cascade chain serially connects the intermediate values. The cascade chain can use a logical AND or logical OR gate (via De Morgan's inversion) to connect the outputs of adjacent LEs. Each additional LE provides four more inputs to the effective width of a function, with a delay as low as 0.5 ns per LE. Cascade chain logic can be created automatically by the Altera software during design processing, or manually by the designer during design entry. Parameterized functions such as LPM and DesignWare functions automatically take advantage of cascade chains for the appropriate functions. A cascade chain implementing an AND gate can use the register in the last LE; a cascade chain implementing an OR gate cannot use this register because of the inversion required to implement the OR gate. Because the first LE of an LAB can generate control signals for that LAB, the first LE in each LAB is not included in cascade chains. Moreover, cascade chains longer than nine bits are automatically implemented by linking several LABs together. For easier routing, a long cascade chain skips every other LAB in a row. A cascade chain longer than one LAB skips either from an even-numbered LAB to another even-numbered LAB, or from an odd-numbered LAB to another odd-numbered LAB. For example, the last LE of the first LAB in a row cascades to the second LE of the third LAB. The cascade chain does not cross the center of the row. For example, in an EPF6016 device, the cascade chain stops at the 11th LAB in a row and a new cascade chain begins at the 12th LAB. Figure 6 shows how the cascade function can connect adjacent LEs to form functions with a wide fan-in. In this example, functions of 4n variables are implemented with n LEs. The cascade chain requires 3.4 ns to decode a 16-bit address. 12 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 6. Cascade Chain Operation AND Cascade Chain OR Cascade Chain LE 2 d[3..0] LUT d[7..4] LUT d[(4n-1)..4(n-1)] LUT LE 2 d[3..0] LUT d[7..4] LUT d[(4n-1)..4(n-1)] LUT LE 3 LE 3 LE n + 1 LE n + 1 LE Operating Modes The FLEX 6000 LE can operate in one of the following three modes: Normal mode Arithmetic mode Counter mode Each of these modes uses LE resources differently. In each mode, seven available inputs to the LE--the four data inputs from the LAB local interconnect, the feedback from the programmable register, and the carry-in and cascade-in from the previous LE--are directed to different destinations to implement the desired logic function. LAB-wide signals provide clock, asynchronous clear, synchronous clear, and synchronous load control for the register. The Altera software, in conjunction with parameterized functions such as LPM and DesignWare functions, automatically chooses the appropriate mode for common functions such as counters, adders, and multipliers. If required, the designer can also create special-purpose functions to use an LE operating mode for optimal performance. Figure 7 shows the LE operating modes. Altera Corporation 13 FLEX 6000 Programmable Logic Device Family Data Sheet Figure 7. LE Operating Modes Normal Mode Cascade-In Carry-In LE-Out data1 data2 D 4-Input LUT data3 data4 PRN Q CLRN Cascade-Out Arithmetic Mode Carry-In Cascade-In LE-Out data1 data2 PRN D Q 3-Input LUT CLRN 3-Input LUT Cascade-Out Carry-Out Counter Mode Cascade-In Carry-In LAB-Wide Synchronous Load (3) LAB-Wide Synchronous Clear (3) (1) data1 (2) data2 (2) 3-Input LUT D PRN Q LE-Out data3 (data) CLRN 3-Input LUT Carry-Out Cascade-Out Notes: (1) (2) (3) The register feedback multiplexer is available on LE 2 of each LAB. The data1 and data2 input signals can supply a clock enable, up or down control, or register feedback signals for all LEs other than the second LE in an LAB. The LAB-wide synchronous clear and LAB-wide synchronous load affect all registers in an LAB. 14 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Normal Mode The normal mode is suitable for general logic applications, combinatorial functions, or wide decoding functions that can take advantage of a cascade chain. In normal mode, four data inputs from the LAB local interconnect and the carry-in are inputs to a 4-input LUT. The Altera software automatically selects the carry-in or the DATA3 signal as one of the inputs to the LUT. The LUT output can be combined with the cascadein signal to form a cascade chain through the cascade-out signal. Arithmetic Mode The arithmetic mode is ideal for implementing adders, accumulators, and comparators. An LE in arithmetic mode uses two 3-input LUTs. One LUT computes a 3-input function; the other generates a carry output. As shown in Figure 7, the first LUT uses the carry-in signal and two data inputs from the LAB local interconnect to generate a combinatorial or registered output. For example, when implementing an adder, this output is the sum of three signals: DATA1, DATA2, and carry-in. The second LUT uses the same three signals to generate a carry-out signal, thereby creating a carry chain. The arithmetic mode also supports simultaneous use of the cascade chain. The Altera software implements logic functions to use the arithmetic mode automatically where appropriate; the designer does not have to decide how the carry chain will be used. Counter Mode The counter mode offers counter enable, synchronous up/down control, synchronous clear, and synchronous load options. The counter enable and synchronous up/down control signals are generated from the data inputs of the LAB local interconnect. The synchronous clear and synchronous load options are LAB-wide signals that affect all registers in the LAB. Consequently, if any of the LEs in a LAB use counter mode, other LEs in that LAB must be used as part of the same counter or be used for a combinatorial function. In addition, the Altera software automatically places registers that are not in the counter into other LABs. The counter mode uses two 3-input LUTs: one generates the counter data and the other generates the fast carry bit. A 2-to-1 multiplexer provides synchronous loading, and another AND gate provides synchronous clearing. If the cascade function is used by an LE in counter mode, the synchronous clear or load will override any signal carried on the cascade chain. The synchronous clear overrides the synchronous load. Altera Corporation 15 FLEX 6000 Programmable Logic Device Family Data Sheet Either the counter enable or the up/down control may be used for a given counter. Moreover, the synchronous load can be used as a count enable by routing the register output into the data input automatically when requested by the designer. The second LE of each LAB has a special function for counter mode; the carry-in of the LE can be driven by a fast feedback path from the register. This function gives a faster counter speed for counter carry chains starting in the second LE of an LAB. The Altera software implements functions to use the counter mode automatically where appropriate. The designer does not have to decide how the carry chain will be used. Internal Tri-State Emulation Internal tri-state emulation provides internal tri-states without the limitations of a physical tri-state bus. In a physical tri-state bus, the tri-state buffers' output enable (OE) signals select which signal drives the bus. However, if multiple OE signals are active, contending signals can be driven onto the bus. Conversely, if no OE signals are active, the bus will float. Internal tri-state emulation resolves contending tri-state buffers to a low value and floating buses to a high value, thereby eliminating these problems. The Altera software automatically implements tri-state bus functionality with a multiplexer. Clear & Preset Logic Control Logic for the programmable register's clear and preset functions is controlled by the LAB-wide signals LABCTRL1 and LABCTRL2. The LE register has an asynchronous clear that can implement an asynchronous preset. Either LABCTRL1 or LABCTRL2 can control the asynchronous clear or preset. Because the clear and preset functions are active-low, the Altera software automatically assigns a logic high to an unused clear or preset signal. The clear and preset logic is implemented in either the asynchronous clear or asynchronous preset mode, which is chosen during design entry (see Figure 8). 16 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 8. LE Clear & Preset Modes Asynchronous Clear Asynchronous Preset D Q CLRN labctrl1 or labctrl2 Chip-Wide Reset D PRN Q labctrl1 or labctrl2 Chip-Wide Reset Asynchronous Clear The flipflop can be cleared by either LABCTRL1 or LABCTRL2. Asynchronous Preset An asynchronous preset is implemented with an asynchronous clear. The Altera software provides preset control by using the clear and inverting the input and output of the register. Inversion control is available for the inputs to both LEs and IOEs. Therefore, this technique can be used when a register drives logic or drives a pin. In addition to the two clear and preset modes, FLEX 6000 devices provide a chip-wide reset pin (DEV_CLRn) that can reset all registers in the device. The option to use this pin is set in the Altera software before compilation. The chip-wide reset overrides all other control signals. Any register with an asynchronous preset will be preset when the chip-wide reset is asserted because of the inversion technique used to implement the asynchronous preset. The Altera software can use a programmable NOT-gate push-back technique to emulate simultaneous preset and clear or asynchronous load. However, this technique uses an additional three LEs per register. FastTrack Interconnect In the FLEX 6000 OptiFLEX architecture, connections between LEs and device I/O pins are provided by the FastTrack Interconnect, a series of continuous horizontal and vertical routing channels that traverse the device. This global routing structure provides predictable performance, even for complex designs. In contrast, the segmented routing in FPGAs requires switch matrices to connect a variable number of routing paths, increasing the delays between logic resources and reducing performance. Altera Corporation 17 FLEX 6000 Programmable Logic Device Family Data Sheet The FastTrack Interconnect consists of column and row interconnect channels that span the entire device. Each row of LABs is served by a dedicated row interconnect, which routes signals between LABs in the same row, and also routes signals from I/O pins to LABs. Additionally, the local interconnect routes signals between LEs in the same LAB and in adjacent LABs. The column interconnect routes signals between rows and routes signals from I/O pins to rows. LEs 1 through 5 of an LAB drive the local interconnect to the right, while LEs 6 through 10 drive the local interconnect to the left. The DATA1 and DATA3 inputs of each LE are driven by the local interconnect to the left; DATA2 and DATA4 are driven by the local interconnect to the right. The local interconnect also routes signals from LEs to I/O pins. Figure 9 shows an overview of the FLEX 6000 interconnect architecture. LEs in the first and last columns have drivers on both sides so that all LEs in the LAB can drive I/O pins via the local interconnect. Figure 9. FastTrack Interconnect Architecture Row Interconnect (n Channels) (1) 2 2 5 5 22 10 5 5 22 10 2 2 20 5 5 20 5 5 5 5 5 5 10 10 To/From Adjacent LAB 5 10 10 10 LE 1 through LE 5 5 10 10 10 LE 1 through LE 5 10 5 10 5 10 5 10 LE 6 through LE 10 10 Local Interconnect (32 Channels) 5 10 LE 6 through LE 10 10 10 To/From Adjacent LAB Column Interconnect (m Channels) (1) Note: (1) 18 For EPF6010A, EPF6016, and EPF6016A devices, n = 144 channels and m = 20 channels; for EPF6024A devices, n = 186 channels and m = 30 channels. Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet A row channel can be driven by an LE or by one of two column channels. These three signals feed a 3-to-1 multiplexer that connects to six specific row channels. Row channels drive into the local interconnect via multiplexers. Each column of LABs is served by a dedicated column interconnect. The LEs in an LAB can drive the column interconnect. The LEs in an LAB, a column IOE, or a row interconnect can drive the column interconnect. The column interconnect can then drive another row's interconnect to route the signals to other LABs in the device. A signal from the column interconnect must be routed to the row interconnect before it can enter an LAB. Each LE has a FastTrack Interconnect output and a local output. The FastTrack interconnect output can drive six row and two column lines directly; the local output drives the local interconnect. Each local interconnect channel driven by an LE can drive four row and two column channels. This feature provides additional flexibility, because each LE can drive any of ten row lines and four column lines. In addition, LEs can drive global control signals. This feature is useful for distributing internally generated clock, asynchronous clear, and asynchronous preset signals. A pin-driven global signal can also drive data signals, which is useful for high-fan-out data signals. Each LAB drives two groups of local interconnects, which allows an LE to drive two LABs, or 20 LEs, via the local interconnect. The row-to-local multiplexers are used more efficiently, because the multiplexers can now drive two LABs. Figure 10 shows how an LAB connects to row and column interconnects. Altera Corporation 19 FLEX 6000 Programmable Logic Device Family Data Sheet Figure 10. LAB Connections to Row & Column Interconnects Each LE FastTrack Interconnect output can drive six row channels. Each local channel driven by an LE can drive two column channels. Each LE output signal driving the FastTrack Interconnect can drive two column channels. At each intersection, four row channels can drive column channels. Row Interconnect Each local channel driven by an LE can drive four row channels. Row interconnect drives the local interconnect. LE From Adjacent Local Interconnect LE Local Interconnect Column Interconnect Any column channel can drive six row channels. An LE can be driven by any signal from two local interconnect areas. For improved routability, the row interconnect consists of full-length and half-length channels. The full-length channels connect to all LABs in a row; the half-length channels connect to the LABs in half of the row. In addition to providing a predictable, row-wide interconnect, this architecture provides increased routing resources. Two neighboring LABs can be connected using a half-length channel, which saves the other half of the channel for the other half of the row. One-third of the row channels are half-length channels. 20 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Table 5 summarizes the FastTrack Interconnect resources available in each FLEX 6000 device. Table 5. FLEX 6000 FastTrack Interconnect Resources Device Rows Channels per Row Columns Channels per Column EPF6010A 4 144 22 20 EPF6016 EPF6016A 6 144 22 20 EPF6024A 7 186 28 30 In addition to general-purpose I/O pins, FLEX 6000 devices have four dedicated input pins that provide low-skew signal distribution across the device. These four inputs can be used for global clock and asynchronous clear control signals. These signals are available as control signals for all LEs in the device. The dedicated inputs can also be used as generalpurpose data inputs because they can feed the local interconnect of each LAB in the device. Using dedicated inputs to route data signals provides a fast path for high fan-out signals. The local interconnect from LABs located at either end of two rows can drive a global control signal. For instance, in an EPF6016 device, LABs C1, D1, C22, and D22 can all drive global control signals. When an LE drives a global control signal, the dedicated input pin that drives that signal cannot be used. Any LE in the device can drive a global control signal by driving the FastTrack Interconnect into the appropriate LAB. To minimize delay, however, the Altera software places the driving LE in the appropriate LAB. The LE-driving-global signal feature is optimized for speed for control signals; regular data signals are better routed on the FastTrack Interconnect and do not receive any advantage from being routed on global signals. This LE-driving-global control signal feature is controlled by the designer and is not used automatically by the Altera software. See Figure 11. Altera Corporation 21 FLEX 6000 Programmable Logic Device Family Data Sheet Figure 11. Global Clock & Clear Distribution (2) LAB C1 Note (1) 4 (3) LAB (Repeated Across Device) (4) LAB C22 Dedicated Inputs Dedicated Inputs (2) (4) LAB D1 LAB D22 Notes: (1) (2) (3) (4) The global clock and clear distribution signals are shown for EPF6016 and EPF6016A devices. In EPF6010A devices, LABs in rows B and C drive global signals. In EPF6024A devices, LABs in rows C and E drive global signals. The local interconnect from LABs C1 and D1 can drive two global control signals on the left side. Global signals drive into every LAB as clock, asynchronous clear, preset, and data signals. The local interconnect from LABs C22 and D22 can drive two global control signals on the right side. 22 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet I/O Elements An IOE contains a bidirectional I/O buffer and a tri-state buffer. IOEs can be used as input, output, or bidirectional pins. An IOE receives its data signals from the adjacent local interconnect, which can be driven by a row or column interconnect (allowing any LE in the device to drive the IOE) or by an adjacent LE (allowing fast clock-to-output delays). A FastFLEXTM I/O pin is a row or column output pin that receives its data signals from the adjacent local interconnect driven by an adjacent LE. The IOE receives its output enable signal through the same path, allowing individual output enables for every pin and permitting emulation of open-drain buffers. The Altera Compiler uses programmable inversion to invert the data or output enable signals automatically where appropriate. Opendrain emulation is provided by driving the data input low and toggling the OE of each IOE. This emulation is possible because there is one OE per pin. A chip-wide output enable feature allows the designer to disable all pins of the device by asserting one pin (DEV_OE). This feature is useful during board debugging or testing. Figure 12 shows the IOE block diagram. Figure 12. IOE Block Diagram To Row or Column Interconnect Delay Chip-Wide Output Enable From LAB Local Interconnect From LAB Local Interconnect Slew-Rate Control Altera Corporation 23 FLEX 6000 Programmable Logic Device Family Data Sheet Each IOE drives a row or column interconnect when used as an input or bidirectional pin. A row IOE can drive up to six row lines; a column IOE can drive up to two column lines. The input path from the I/O pad to the FastTrack Interconnect has a programmable delay element that can be used to guarantee a zero hold time. Depending on the placement of the IOE relative to what it is driving, the designer may choose to turn on the programmable delay to ensure a zero hold time. Figure 13 shows how an IOE connects to a row interconnect, and Figure 14 shows how an IOE connects to a column interconnect. Figure 13. IOE Connection to Row Interconnect Row Interconnect Any LE can drive a pin through the row and local interconnect. IOE LAB IOE Up to 10 IOEs are on either side of a row. Each IOE can drive up to six row channels, and each IOE data and OE signal is driven by the local interconnect. FastFLEX I/O: An LE can drive a pin through the local interconnect for faster clock-to-output times. 24 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 14. IOE Connection to Column Interconnect Each IOE can drive two column interconnect channels. Each IOE data and OE signal is driven to a local interconnect. IOE IOE FastFLEX I/O: An LE can drive a pin through a local interconnect for faster clock-to-output times. LAB Any LE can drive a pin through the row and local interconnect. Column Interconnect Row Interconnect SameFrame Pin-Outs 3.3-V FLEX 6000 devices support the SameFrame pin-out feature for FineLine BGA packages. The SameFrame pin-out feature is the arrangement of balls on FineLine BGA packages such that the lower-ballcount packages form a subset of the higher-ball-count packages. SameFrame pin-outs provide the flexibility to migrate not only from device to device within the same package, but also from one package to another. A given printed circuit board (PCB) layout can support multiple device density/package combinations. For example, a single board layout can support an EPF6016A device in a 100-pin FineLine BGA package or an EPF6024A device in a 256-pin FineLine BGA package. The Altera software packages provide support to design PCBs with SameFrame pin-out devices. Devices can be defined for present and future use. The Altera software packages generate pin-outs describing how to lay out a board to take advantage of this migration (see Figure 15). Altera Corporation 25 FLEX 6000 Programmable Logic Device Family Data Sheet Figure 15. SameFrame Pin-Out Example Printed Circuit Board Designed for 256-Pin FineLine BGA Package 100-Pin FineLine BGA 256-Pin FineLine BGA 100-Pin FineLine BGA Package (Reduced I/O Count or Logic Requirements) 256-Pin FineLine BGA Package (Increased I/O Count or Logic Requirements) Table 6 lists the 3.3-V FLEX 6000 devices with the SameFrame pin-out feature. Table 6. 3.3-V FLEX 6000 Devices with SameFrame Pin-Outs Device 100-Pin FineLine BGA 256-Pin FineLine BGA EPF6016A v v EPF6024A Output Configuration v This section discusses slew-rate control, the MultiVolt I/O interface, power sequencing, and hot-socketing for FLEX 6000 devices. Slew-Rate Control The output buffer in each IOE has an adjustable output slew-rate that can be configured for low-noise or high-speed performance. A slower slew-rate reduces system noise and adds a maximum delay of 6.8 ns. The fast slew-rate should be used for speed-critical outputs in systems that are adequately protected against noise. Designers can specify the slew-rate on a pin-by-pin basis during design entry or assign a default slew rate to all pins on a device-wide basis. The slew-rate setting affects only the falling edge of the output. 26 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet MultiVolt I/O Interface The FLEX 6000 device architecture supports the MultiVolt I/O interface feature, which allows FLEX 6000 devices to interface with systems of differing supply voltages. The EPF6016 device can be set for 3.3-V or 5.0-V I/O pin operation. This device has one set of VCC pins for internal operation and input buffers (VCCINT), and another set for output drivers (VCCIO). The VCCINT pins on 5.0-V FLEX 6000 devices must always be connected to a 5.0-V power supply. With a 5.0-V VCCINT level, input voltages are at TTL levels and are therefore compatible with 3.3-V and 5.0-V inputs. The VCCIO pins on 5.0-V FLEX 6000 devices can be connected to either a 3.3-V or 5.0-V power supply, depending on the output requirements. When the VCCIO pins are connected to a 5.0-V power supply, the output levels are compatible with 5.0-V systems. When the VCCIO pins are connected to a 3.3-V power supply, the output high is 3.3 V and is therefore compatible with 3.3-V or 5.0-V systems. Devices operating with VCCIO levels lower than 4.75 V incur a nominally greater timing delay of tOD2 instead of tOD1. On 3.3-V FLEX 6000 devices, the VCCINT pins must be connected to a 3.3-V power supply. Additionally, 3.3-V FLEX 6000A devices can interface with 2.5-V, 3.3-V, or 5.0-V systems when the VCCIO pins are tied to 2.5 V. The output can drive 2.5-V systems, and the inputs can be driven by 2.5V, 3.3-V, or 5.0-V systems. When the VCCIO pins are tied to 3.3 V, the output can drive 3.3-V or 5.0-V systems. MultiVolt I/Os are not supported on 100-pin TQFP or 100-pin FineLine BGA packages. Table 7 describes FLEX 6000 MultiVolt I/O support. Table 7. FLEX 6000 MultiVolt I/O Support VCCINT (V) VCCIO (V) 3.3 Input Signal (V) Output Signal (V) 2.5 3.3 5.0 2.5 2.5 v v v v 3.3 3.3 v v v v (1) 5.0 3.3 v v 5.0 5.0 v v 3.3 5.0 v v v v v Note: (1) Altera Corporation When VCCIO = 3.3 V, a FLEX 6000 device can drive a 2.5-V device that has 3.3-V tolerant inputs. 27 FLEX 6000 Programmable Logic Device Family Data Sheet Open-drain output pins on 5.0-V or 3.3-V FLEX 6000 devices (with a pullup resistor to the 5.0-V supply) can drive 5.0-V CMOS input pins that require a VIH of 3.5 V. When the open-drain pin is active, it will drive low. When the pin is inactive, the trace will be pulled up to 5.0 V by the resistor. The open-drain pin will only drive low or tri-state; it will never drive high. The rise time is dependent on the value of the pull-up resistor and load impedance. The IOL current specification should be considered when selecting a pull-up resistor. Output pins on 5.0-V FLEX 6000 devices with VCCIO = 3.3 V or 5.0 V (with a pull-up resistor to the 5.0-V supply) can also drive 5.0-V CMOS input pins. In this case, the pull-up transistor will turn off when the pin voltage exceeds 3.3 V. Therefore, the pin does not have to be open-drain. Power Sequencing & Hot-Socketing Because FLEX 6000 family devices can be used in a mixed-voltage environment, they have been designed specifically to tolerate any possible power-up sequence. The VCCIO and VCCINT power planes can be powered in any order. Signals can be driven into 3.3-V FLEX 6000 devices before and during power up without damaging the device. Additionally, FLEX 6000 devices do not drive out during power up. Once operating conditions are reached, FLEX 6000 devices operate as specified by the user. IEEE Std. 1149.1 (JTAG) Boundary-Scan Support All FLEX 6000 devices provide JTAG BST circuitry that comply with the IEEE Std. 1149.1-1990 specification. Table 8 shows JTAG instructions for FLEX 6000 devices. JTAG BST can be performed before or after configuration, but not during configuration (except when you disable JTAG support in user mode). 1 See Application Note 39 (IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera Devices) for more information on JTAG BST circuitry. Table 8. FLEX 6000 JTAG Instructions JTAG Instruction Description SAMPLE/PRELOAD Allows a snapshot of the signals at the device pins to be captured and examined during normal device operation, and permits an initial data pattern to be output at the device pins. EXTEST Allows the external circuitry and board-level interconnections to be tested by forcing a test pattern at the output pins and capturing test result at the input pins. BYPASS Places the 1-bit bypass register between the TDI and TDO pins, which allows the BST data to pass synchronously through the selected device to adjacent devices during normal device operation. 28 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet The instruction register length for FLEX 6000 devices is three bits. Table 9 shows the boundary-scan register length for FLEX 6000 devices. Table 9. FLEX 6000 Device Boundary-Scan Register Length Device Boundary-Scan Register Length EPF6010A 522 EPF6016 621 EPF6016A 522 EPF6024A 666 FLEX 6000 devices include a weak pull-up on JTAG pins. f See Application Note 39 (IEEE 1149.1 (JTAG) Boundary-Scan Testing in Altera Devices) for more information. Figure 16 shows the timing requirements for the JTAG signals. Figure 16. JTAG Waveforms TMS TDI t JCP t JCH t JCL t JPSU t JPH TCK tJPZX t JPXZ t JPCO TDO tJSSU Signal to Be Captured Signal to Be Driven tJSZX tJSH tJSCO tJSXZ Table 10 shows the JTAG timing parameters and values for FLEX 6000 devices. Altera Corporation 29 FLEX 6000 Programmable Logic Device Family Data Sheet Table 10. JTAG Timing Parameters & Values Symbol Generic Testing Parameter Min Max Unit tJCP TCK clock period 100 ns tJCH TCK clock high time 50 ns tJCL TCK clock low time 50 ns tJPSU JTAG port setup time 20 ns tJPH JTAG port hold time 45 tJPCO JTAG port clock-to-output 25 tJPZX JTAG port high impedance to valid output 25 ns tJPXZ JTAG port valid output to high impedance 25 ns tJSSU Capture register setup time 20 tJSH Capture register hold time 45 tJSCO Update register clock-to-output 35 ns tJSZX Update register high impedance to valid output 35 ns tJSXZ Update register valid output to high impedance 35 ns ns ns ns ns Each FLEX 6000 device is functionally tested. Complete testing of each configurable SRAM bit and all logic functionality ensures 100% configuration yield. AC test measurements for FLEX 6000 devices are made under conditions equivalent to those shown in Figure 17. Multiple test patterns can be used to configure devices during all stages of the production flow. Figure 17. AC Test Conditions Power supply transients can affect AC measurements. Simultaneous transitions of multiple outputs should be avoided for accurate 464 measurement. Threshold tests must (703 ) not be performed under AC conditions. [521 ] Large-amplitude, fast-ground-current transients normally occur as the Device device outputs discharge the load Output capacitances. When these transients flow through the parasitic inductance between the device 250 ground pin and the test system ground, (8.06 k) significant reductions in observable [481 ] noise immunity can result. Numbers Device input without parentheses are for 5.0-V rise and fall devices or outputs. Numbers in times < 3 ns parentheses are for 3.3-V devices or outputs. Numbers in brackets are for 2.5-V devices or outputs. 30 VCC To Test System C1 (includes JIG capacitance) Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Operating Conditions Tables 11 through 18 provide information on absolute maximum ratings, recommended operating conditions, operating conditions, and capacitance for 5.0-V and 3.3-V FLEX 6000 devices. Table 11. FLEX 6000 5.0-V Device Absolute Maximum Ratings Symbol Parameter Note (1) Conditions Min Max Unit With respect to ground (2) V V CC Supply voltage -2.0 7.0 VI DC input voltage -2.0 7.0 V I OUT DC output current, per pin -25 25 mA T STG Storage temperature No bias -65 150 C T AMB Ambient temperature Under bias -65 135 C TJ Junction temperature PQFP, TQFP, and BGA packages 135 C Min Max Unit Table 12. FLEX 6000 5.0-V Device Recommended Operating Conditions Symbol Parameter Conditions V CCINT Supply voltage for internal logic and input buffers (3), (4) 4.75 (4.50) 5.25 (5.50) V V CCIO Supply voltage for output buffers, (3), (4) 5.0-V operation 4.75 (4.50) 5.25 (5.50) V Supply voltage for output buffers, (3), (4) 3.3-V operation 3.00 (3.00) 3.60 (3.60) V -0.5 V CCINT + 0.5 V 0 V CCIO V VI Input voltage VO Output voltage TJ Operating temperature For commercial use For industrial use 0 85 C -40 100 C tR Input rise time 40 ns tF Input fall time 40 ns Altera Corporation 31 FLEX 6000 Programmable Logic Device Family Data Sheet Table 13. FLEX 6000 5.0-V Device DC Operating Conditions Symbol Parameter Notes (5), (6) Conditions Min Typ Max Unit V V IH High-level input voltage 2.0 V CCINT + 0.5 V IL Low-level input voltage -0.5 0.8 V OH 5.0-V high-level TTL output voltage I OH = -8 mA DC, V CCIO = 4.75 V (7) 2.4 V 3.3-V high-level TTL output voltage I OH = -8 mA DC, V CCIO = 3.00 V (7) 2.4 V 3.3-V high-level CMOS output voltage I OH = -0.1 mA DC, V CCIO = 3.00 V (7) V CCIO - 0.2 V 5.0-V low-level TTL output voltage I OL = 8 mA DC, V CCIO = 4.75 V (8) 0.45 V 3.3-V low-level TTL output voltage I OL = 8 mA DC, V CCIO = 3.00 V (8) 0.45 V 3.3-V low-level CMOS output voltage I OL = 0.1 mA DC, V CCIO = 3.00 V (8) 0.2 V II Input pin leakage current V I = V CC or ground (8) -10 10 A I OZ Tri-stated I/O pin leakage current V O = V CC or ground (8) V CC supply current (standby) V I = ground, no load -40 40 A 5 mA V OL I CC0 Table 14. FLEX 6000 5.0-V Device Capacitance Symbol Parameter 0.5 V Note (9) Max Unit C IN Input capacitance for I/O pin V IN = 0 V, f = 1.0 MHz Conditions 8 pF CINCLK Input capacitance for dedicated input V IN = 0 V, f = 1.0 MHz 12 pF C OUT Output capacitance 8 pF V OUT = 0 V, f = 1.0 MHz Min Notes to tables: (1) (2) (9) See the Operating Requirements for Altera Devices Data Sheet. Minimum DC input is -0.5 V. During transitions, the inputs may undershoot to -2.0 V or overshoot to 7.0 V for input currents less than 100 mA and periods shorter than 20 ns. Numbers in parentheses are for industrial-temperature-range devices. Maximum VCC rise time to 100 ms. VCC must rise monotonically. Typical values are for T A = 25 C and V CC = 5.0 V. These values are specified under the FLEX 6000 Recommended Operating Conditions shown in Table 12 on page 31. The IOH parameter refers to high-level TTL or CMOS output current. The IOL parameter refers to low-level TTL, PCI, or CMOS output current. This parameter applies to open-drain pins as well as output pins. Capacitance is sample-tested only. 32 Altera Corporation (3) (4) (5) (6) (7) (8) FLEX 6000 Programmable Logic Device Family Data Sheet Table 15. FLEX 6000 3.3-V Device Absolute Maximum Ratings Symbol Parameter Note (1) Min Max Unit -0.5 4.6 V DC input voltage -2.0 5.75 V I OUT DC output current, per pin -25 25 mA T STG Storage temperature No bias -65 150 C T AMB Ambient temperature Under bias -65 135 C TJ Junction temperature PQFP, PLCC, and BGA packages 135 C V CC Supply voltage VI Conditions With respect to ground (2) Table 16. FLEX 6000 3.3-V Device Recommended Operating Conditions Min Max Unit V CCINT Symbol Supply voltage for internal logic and (3), (4) input buffers Parameter 3.00 (3.00) 3.60 (3.60) V V CCIO Supply voltage for output buffers, 3.3-V operation (3), (4) 3.00 (3.00) 3.60 (3.60) V Supply voltage for output buffers, 2.5-V operation (3), (4) 2.30 (2.30) 2.70 (2.70) V VI Input voltage VO Output voltage TJ Operating temperature Conditions For commercial use For industrial use -0.5 5.75 V 0 V CCIO V 0 85 C -40 100 C tR Input rise time 40 ns tF Input fall time 40 ns Altera Corporation 33 FLEX 6000 Programmable Logic Device Family Data Sheet Table 17. FLEX 6000 3.3-V Device DC Operating Conditions Symbol Parameter Notes (5), (6) Conditions Min Typ Max Unit V IH High-level input voltage 1.7 5.75 V V IL Low-level input voltage -0.5 0.8 V V OH 3.3-V high-level TTL output voltage I OH = -8 mA DC, V CCIO = 3.00 V (7) 3.3-V high-level CMOS output voltage 2.5-V high-level output voltage V OL 2.4 V I OH = -0.1 mA DC, V CCIO = 3.00 V (7) V CCIO - 0.2 V I OH = -100 A DC, V CCIO = 2.30 V (7) 2.1 V I OH = -1 mA DC, V CCIO = 2.30 V (7) 2.0 V I OH = -2 mA DC, V CCIO = 2.30 V (7) 1.7 V 3.3-V low-level TTL output voltage I OL = 8 mA DC, V CCIO = 3.00 V (8) 0.45 V 3.3-V low-level CMOS output voltage I OL = 0.1 mA DC, V CCIO = 3.00 V (8) 0.2 V 2.5-V low-level output voltage I OL = 100 A DC, V CCIO = 2.30 V (8) 0.2 V I OL = 1 mA DC, V CCIO = 2.30 V (8) 0.4 V I OL = 2 mA DC, V CCIO = 2.30 V (8) 0.7 V 10 A II Input pin leakage current V I = 5.3 V to ground (8) I OZ Tri-stated I/O pin leakage current V O = 5.3 V to ground (8) I CC0 V CC supply current (standby) Parameter -10 V I = ground, no load Table 18. FLEX 6000 3.3-V Device Capacitance Symbol -10 0.5 10 A 5 mA Note (9) Max Unit C IN Input capacitance for I/O pin V IN = 0 V, f = 1.0 MHz Conditions 8 pF CINCLK Input capacitance for dedicated input V IN = 0 V, f = 1.0 MHz 12 pF C OUT Output capacitance 8 pF V OUT = 0 V, f = 1.0 MHz Min Notes to tables: (1) (2) (9) See the Operating Requirements for Altera Devices Data Sheet. The minimum DC input voltage is -0.5 V. During transitions, the inputs may undershoot to -2.0 V or overshoot to 5.75 V for input currents less than 100 mA and periods shorter than 20 ns. Numbers in parentheses are for industrial-temperature-range devices. Maximum VCC rise time is 100 ms. VCC must rise monotonically. Typical values are for T A = 25 C and V CC = 3.3 V. These values are specified under Table 16 on page 33. The IOH parameter refers to high-level TTL or CMOS output current. The IOL parameter refers to low-level TTL, PCI, or CMOS output current. This parameter applies to open-drain pins as well as output pins. Capacitance is sample-tested only. 34 Altera Corporation (3) (4) (5) (6) (7) (8) FLEX 6000 Programmable Logic Device Family Data Sheet Figure 18 shows the typical output drive characteristics of 5.0-V and 3.3-V FLEX 6000 devices with 5.0-V, 3.3-V, and 2.5-V VCCIO. When VCCIO = 5.0 V on EPF6016 devices, the output driver is compliant with the PCI Local Bus Specification, Revision 2.2 for 5.0-V operation. When VCCIO = 3.3 V on the EPF6010A and EPF6016A devices, the output driver is compliant with the PCI Local Bus Specification, Revision 2.2 for 3.3-V operation. Figure 18. Output Drive Characteristics EPF6010A EPF6016A EPF6010A EPF6016A VCCINT = 3.3 V VCCIO = 3.3 V Room Temperature 100 75 Typical IO Output Current (mA) VCCINT = 3.3 V VCCIO = 2.5 V Room Temperature 100 75 Typical IO Output Current (mA) IOL 50 IOL 50 IOH IOH 25 25 1 2 3 4 5 1 VO Output Voltage (V) 2 EPF6016 4 5 EPF6016 150 150 IOL IOL 120 120 90 Typical IO Output Current (mA) 90 Typical IO Output Current (mA) VCCINT = 5.0 V VCCIO = 5.0 V Room Temperature 60 1 2 VCCINT = 5.0 V VCCIO = 3.3 V Room Temperature 60 IOH IOH 30 30 3 4 1 5 2 3 3.3 4 5 VO Output Voltage (V) VO Output Voltage (V) EPF6024A EPF6024A 100 100 VCCINT = 3.3 V VCCIO = 3.3 V Room Temperature 75 Typical IO Output Current (mA) VCCINT = 3.3 V VCCIO = 2.5 V Room Temperature 75 Typical IO Output Current (mA) IOL 50 IOL 50 25 25 IOH 1 2 3 IOH 4 VO Output Voltage (V) Altera Corporation 3 VO Output Voltage (V) 5 1 2 3 4 5 VO Output Voltage (V) 35 FLEX 6000 Programmable Logic Device Family Data Sheet Timing Model The continuous, high-performance FastTrack Interconnect routing resources ensure predictable performance and accurate simulation and timing analysis. This predictable performance contrasts with that of FPGAs, which use a segmented connection scheme and therefore have unpredictable performance. Device performance can be estimated by following the signal path from a source, through the interconnect, to the destination. For example, the registered performance between two LEs on the same row can be calculated by adding the following parameters: LE register clock-to-output delay (tCO + tREG_TO_OUT) Routing delay (tROW + tLOCAL) LE LUT delay (tDATA_TO_REG) LE register setup time (tSU) The routing delay depends on the placement of the source and destination LEs. A more complex registered path may involve multiple combinatorial LEs between the source and destination LEs. Timing simulation and delay prediction are available with the Simulator and Timing Analyzer, or with industry-standard EDA tools. The Simulator offers both pre-synthesis functional simulation to evaluate logic design accuracy and post-synthesis timing simulation with 0.1-ns resolution. The Timing Analyzer provides point-to-point timing delay information, setup and hold time analysis, and device-wide performance analysis. Figure 19 shows the overall timing model, which maps the possible routing paths to and from the various elements of the FLEX 6000 device. 36 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 19. FLEX 6000 Timing Model tROW Carry-In from Previous LE tLOCAL Cascade-In from Previous LE tCASC_TO_OUT tCARRY_TO_OUT tDATA_TO_OUT tREG_TO_OUT tSU tH tCO tCLR tREG_TO_REG tCASC_TO_REG tCARRY_TO_REG tDATA_TO_REG tCOL tC tLD_CLR tLEGLOBAL tCARRY_TO_CARRY tREG_TO_CARRY tDATA_TO_CARRY tDIN_D tLABCARRY tCARRY_TO_CASC tCASC_TO_CASC tREG_TO_CASC tDATA_TO_CASC LE tLABCASC tDIN_C Carry-out to Carry-out to Next LE in Next LE in Same LAB Next LAB tIOE Cascade-out Cascade-out to Next LE in to Next LE in Same LAB Next LAB I/O Pin tOD1 tOD2 tOD3 tXZ tZX1 tZX2 tZX3 tIN tIN_DELAY IOE Altera Corporation 37 FLEX 6000 Programmable Logic Device Family Data Sheet Tables 19 through 21 describe the FLEX 6000 internal timing microparameters, which are expressed as worst-case values. Using hand calculations, these parameters can be used to estimate design performance. However, before committing designs to silicon, actual worst-case performance should be modeled using timing simulation and timing analysis. Tables 22 and 23 describe FLEX 6000 external timing parameters. Table 19. LE Timing Microparameters Note (1) Symbol Parameter tREG_TO_REG LUT delay for LE register feedback in carry chain tCASC_TO_REG Cascade-in to register delay tCARRY_TO_REG Carry-in to register delay tDATA_TO_REG LE input to register delay tCASC_TO_OUT Cascade-in to LE output delay tCARRY_TO_OUT Carry-in to LE output delay tDATA_TO_OUT LE input to LE output delay tREG_TO_OUT Register output to LE output delay tSU LE register setup time before clock; LE register recovery time after asynchronous clear tH LE register hold time after clock tCO LE register clock-to-output delay tCLR LE register clear delay tC LE register control signal delay tLD_CLR Synchronous load or clear delay in counter mode Conditions tCARRY_TO_CARRY Carry-in to carry-out delay tREG_TO_CARRY Register output to carry-out delay tDATA_TO_CARRY LE input to carry-out delay tCARRY_TO_CASC Carry-in to cascade-out delay tCASC_TO_CASC Cascade-in to cascade-out delay tREG_TO_CASC Register-out to cascade-out delay tDATA_TO_CASC LE input to cascade-out delay tCH LE register clock high time tCL LE register clock low time 38 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Table 20. IOE Timing Microparameters Note (1) Symbol Parameter Conditions tOD1 Output buffer and pad delay, slow slew rate = off, VCCIO = VCCINT C1 = 35 pF (2) tOD2 Output buffer and pad delay, slow slew rate = off, VCCIO = low voltage C1 = 35 pF (3) tOD3 Output buffer and pad delay, slow slew rate = on C1 = 35 pF (4) tXZ Output buffer disable delay C1 = 5 pF C1 = 35 pF (2) tZX1 Output buffer enable delay, slow slew rate = off, VCCIO = VCCINT tZX2 Output buffer enable delay, slow slew rate = off, VCCIO = low voltage C1 = 35 pF (3) tZX3 IOE output buffer enable delay, slow slew rate = on C1 = 35 pF (4) tIOE Output enable control delay tIN Input pad and buffer to FastTrack Interconnect delay tIN_DELAY Input pad and buffer to FastTrack Interconnect delay with additional delay turned on Table 21. Interconnect Timing Microparameters Symbol Note (1) Parameter Conditions tLOCAL LAB local interconnect delay tROW Row interconnect routing delay (5) tCOL Column interconnect routing delay (5) tDIN_D Dedicated input to LE data delay (5) tDIN_C Dedicated input to LE control delay tLEGLOBAL LE output to LE control via internally-generated global signal delay tLABCARRY Routing delay for the carry-out of an LE driving the carry-in signal of a different LE in a different LAB tLABCASC Routing delay for the cascade-out signal of an LE driving the cascade-in signal of a different LE in a different LAB (5) Table 22. External Reference Timing Parameters Symbol Parameter Conditions t1 Register-to-register test pattern (6) tDRR Register-to-register delay via 4 LEs, 3 row interconnects, and 4 local interconnects (7) Altera Corporation 39 FLEX 6000 Programmable Logic Device Family Data Sheet Table 23. External Timing Parameters Symbol Parameter Conditions tINSU Setup time with global clock at LE register (8) tINH Hold time with global clock at LE register (8) tOUTCO Clock-to-output delay with global clock with LE register using FastFLEX I/O pin (8) Notes to tables: (1) (2) (3) (4) (5) (6) (7) (8) Microparameters are timing delays contributed by individual architectural elements and cannot be measured explicitly. Operating conditions: VCCIO = 5.0 V 5% for commercial use in 5.0-V FLEX 6000 devices. VCCIO = 5.0 V 10% for industrial use in 5.0-V FLEX 6000 devices. VCCIO = 3.3 V 10% for commercial or industrial use in 3.3-V FLEX 6000 devices. Operating conditions: VCCIO = 3.3 V 10% for commercial or industrial use in 5.0-V FLEX 6000 devices. VCCIO = 2.5 V 0.2 V for commercial or industrial use in 3.3-V FLEX 6000 devices. Operating conditions: VCCIO = 2.5 V, 3.3 V, or 5.0 V. These parameters are worst-case values for typical applications. Post-compilation timing simulation and timing analysis are required to determine actual worst-case performance. This timing parameter shows the delay of a register-to-register test pattern and is used to determine speed grades. There are 12 LEs, including source and destination registers. The row and column interconnects between the registers vary in length. This timing parameter is shown for reference and is specified by characterization. This timing parameter is specified by characterization. Tables 24 through 28 show the timing information for EPF6010A and EPF6016A devices. Table 24. LE Timing Microparameters for EPF6010A & EPF6016A Devices (Part 1 of 2) Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tREG_TO_REG 1.2 1.3 1.7 ns tCASC_TO_REG 0.9 1.0 1.2 ns tCARRY_TO_REG 0.9 1.0 1.2 ns tDATA_TO_REG 1.1 1.2 1.5 ns tCASC_TO_OUT 1.3 1.4 1.8 ns tCARRY_TO_OUT 1.6 1.8 2.3 ns tDATA_TO_OUT 1.7 2.0 2.5 ns tREG_TO_OUT 0.4 0.4 0.5 ns tSU 0.9 1.0 1.3 ns tH 1.4 1.7 2.1 ns 40 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Table 24. LE Timing Microparameters for EPF6010A & EPF6016A Devices (Part 2 of 2) Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tCO 0.3 0.4 0.4 ns tCLR 0.4 0.4 0.5 ns tC 1.8 2.1 2.6 ns tLD_CLR 1.8 2.1 2.6 ns tCARRY_TO_CARRY 0.1 0.1 0.1 ns tREG_TO_CARRY 1.6 1.9 2.3 ns tDATA_TO_CARRY 2.1 2.5 3.0 ns tCARRY_TO_CASC 1.0 1.1 1.4 ns tCASC_TO_CASC 0.5 0.6 0.7 ns tREG_TO_CASC 1.4 1.7 2.1 ns tDATA_TO_CASC 1.1 1.2 1.5 ns tCH 2.5 3.0 3.5 ns tCL 2.5 3.0 3.5 ns Table 25. IOE Timing Microparameters for EPF6010A & EPF6016A Devices Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tOD1 1.9 2.2 2.7 ns tOD2 4.1 4.8 5.8 ns tOD3 5.8 6.8 8.3 ns tXZ 1.4 1.7 2.1 ns tXZ1 1.4 1.7 2.1 ns tXZ2 3.6 4.3 5.2 ns tXZ3 5.3 6.3 7.7 ns tIOE 0.5 0.6 0.7 ns tIN 3.6 4.1 5.1 ns tIN_DELAY 4.8 5.4 6.7 ns Altera Corporation 41 FLEX 6000 Programmable Logic Device Family Data Sheet Table 26. Interconnect Timing Microparameters for EPF6010A & EPF6016A Devices Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tLOCAL 0.7 0.7 1.0 ns tROW 2.9 3.2 3.2 ns tCOL 1.2 1.3 1.4 ns tDIN_D 5.4 5.7 6.4 ns tDIN_C 4.3 5.0 6.1 ns tLEGLOBAL 2.6 3.0 3.7 ns tLABCARRY 0.7 0.8 0.9 ns tLABCASC 1.3 1.4 1.8 ns Table 27. External Reference Timing Parameters for EPF6010A & EPF6016A Devices Parameter Device Speed Grade -1 Min t1 Unit -2 Max Min -3 Max Min Max EPF6010A 37.6 43.6 53.7 ns EPF6016A 38.0 44.0 54.1 ns Table 28. External Timing Parameters for EPF6010A & EPF6016A Devices Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min tINSU 2.1 (1) 2.4 (1) 3.3 (1) tINH 0.2 (2) 0.3 (2) 0.1 (2) tOUTCO 2.0 7.1 2.0 8.2 2.0 Max ns ns 10.1 ns Notes: (1) (2) Setup times are longer when the Increase Input Delay option is turned on. The setup time values are shown with the Increase Input Delay option turned off. Hold time is zero when the Increase Input Delay option is turned on. 42 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Tables 29 through 33 show the timing information for EPF6016 devices. Table 29. LE Timing Microparameters for EPF6016 Devices Parameter Speed Grade -2 Min Unit -3 Max Min Max tREG_TO_REG 2.2 2.8 ns tCASC_TO_REG 0.9 1.2 ns tCARRY_TO_REG 1.6 2.1 ns tDATA_TO_REG 2.4 3.0 ns tCASC_TO_OUT 1.3 1.7 ns tCARRY_TO_OUT 2.4 3.0 ns tDATA_TO_OUT 2.7 3.4 ns tREG_TO_OUT 0.3 0.5 ns tSU 1.1 1.6 tH 1.8 2.3 ns ns tCO 0.3 0.4 ns tCLR 0.5 0.6 ns tC 1.2 1.5 ns tLD_CLR 1.2 1.5 ns tCARRY_TO_CARRY 0.2 0.4 ns tREG_TO_CARRY 0.8 1.1 ns tDATA_TO_CARRY 1.7 2.2 ns tCARRY_TO_CASC 1.7 2.2 ns tCASC_TO_CASC 0.9 1.2 ns tREG_TO_CASC 1.6 2.0 ns tDATA_TO_CASC 1.7 2.1 ns tCH 4.0 4.0 ns tCL 4.0 4.0 ns Table 30. IOE Timing Microparameters for EPF6016 Devices Parameter Speed Grade -2 Min Unit -3 Max Min Max tOD1 2.3 2.8 ns tOD2 4.6 5.1 ns Altera Corporation 43 FLEX 6000 Programmable Logic Device Family Data Sheet Table 30. IOE Timing Microparameters for EPF6016 Devices Parameter Speed Grade -2 Min Unit -3 Max Min Max tOD3 4.7 5.2 ns tXZ 2.3 2.8 ns tZX1 2.3 2.8 ns tZX2 4.6 5.1 ns tZX3 4.7 5.2 ns tIOE 0.5 0.6 ns tIN 3.3 4.0 ns tIN_DELAY 4.6 5.6 ns Table 31. Interconnect Timing Microparameters for EPF6016 Devices Parameter Speed Grade -2 Min Unit -3 Max Min Max tLOCAL 0.8 1.0 ns tROW 2.9 3.3 ns tCOL 2.3 2.5 ns tDIN_D 4.9 6.0 ns tDIN_C 4.8 6.0 ns tLEGLOBAL 3.1 3.9 ns tLABCARRY 0.4 0.5 ns tLABCASC 0.8 1.0 ns Table 32. External Reference Timing Parameters for EPF6016 Devices Parameter Speed Grade -2 Min Unit -3 Max Min Max t1 53.0 65.0 ns tDRR 16.0 20.0 ns 44 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Table 33. External Timing Parameters for EPF6016 Devices Parameter Speed Grade -2 Min tINSU 3.2 tINH 0.0 tOUTCO 2.0 Unit -3 Max Min Max 4.1 ns 0.0 7.9 ns 2.0 9.9 ns Tables 34 through 38 show the timing information for EPF6024A devices. Table 34. LE Timing Microparameters for EPF6024A Devices Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tREG_TO_REG 1.2 1.3 1.6 ns tCASC_TO_REG 0.7 0.8 1.0 ns tCARRY_TO_REG 1.6 1.8 2.2 ns tDATA_TO_REG 1.3 1.4 1.7 ns tCASC_TO_OUT 1.2 1.3 1.6 ns tCARRY_TO_OUT 2.0 2.2 2.6 ns tDATA_TO_OUT 1.8 2.1 2.6 ns tREG_TO_OUT 0.3 0.3 0.4 ns tSU 0.9 1.0 1.2 tH 1.3 1.4 1.7 ns ns tCO 0.2 0.3 0.3 ns tCLR 0.3 0.3 0.4 ns tC 1.9 2.1 2.5 ns tLD_CLR 1.9 2.1 2.5 ns tCARRY_TO_CARRY 0.2 0.2 0.3 ns tREG_TO_CARRY 1.4 1.6 1.9 ns tDATA_TO_CARRY 1.3 1.4 1.7 ns tCARRY_TO_CASC 1.1 1.2 1.4 ns tCASC_TO_CASC 0.7 0.8 1.0 ns tREG_TO_CASC 1.4 1.6 1.9 ns tDATA_TO_CASC 1.0 1.1 1.3 ns tCH 2.5 3.0 3.5 ns tCL 2.5 3.0 3.5 ns Altera Corporation 45 FLEX 6000 Programmable Logic Device Family Data Sheet Table 35. IOE Timing Microparameters for EPF6024A Devices Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tOD1 1.9 2.1 2.5 ns tOD2 4.0 4.4 5.3 ns tOD3 7.0 7.8 9.3 ns tXZ 4.3 4.8 5.8 ns tXZ1 4.3 4.8 5.8 ns tXZ2 6.4 7.1 8.6 ns tXZ3 9.4 10.5 12.6 ns tIOE 0.5 0.6 0.7 ns tIN 3.3 3.7 4.4 ns tIN_DELAY 5.3 5.9 7.0 ns Table 36. Interconnect Timing Microparameters for EPF6024A Devices Parameter Speed Grade -1 Min Unit -2 Max Min -3 Max Min Max tLOCAL 0.8 0.8 1.1 ns tROW 3.0 3.1 3.3 ns tCOL 3.0 3.2 3.4 ns tDIN_D 5.4 5.6 6.2 ns tDIN_C 4.6 5.1 6.1 ns tLEGLOBAL 3.1 3.5 4.3 ns tLABCARRY 0.6 0.7 0.8 ns tLABCASC 0.3 0.3 0.4 ns Table 37. External Reference Timing Parameters for EPF6024A Devices Parameter Speed Grade -1 Min t1 46 Unit -2 Max 45.0 Min -3 Max 50.0 Min Max 60.0 ns Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Table 38. External Timing Parameters for EPF6024A Devices Parameter Speed Grade -1 Min -2 Max tINSU 2.0 (1) tINH 0.2 (2) tOUTCO 2.0 Unit Min -3 Max 2.2 (1) 2.0 Max 2.6 (1) 0.2 (2) 7.4 Min ns 0.3 (2) 8.2 2.0 ns 9.9 ns Notes: (1) (2) Setup times are longer when the Increase Input Delay option is turned on. The setup time values are shown with the Increase Input Delay option turned off. Hold time is zero when the Increase Input Delay option is turned on. Power Consumption The supply power (P) for FLEX 6000 devices can be calculated with the following equations: P = PINT + PIO P = (ICCSTANDBY + ICCACTIVE) x VCC + PIO Typical ICCSTANDBY values are shown as ICC0 in the "FLEX 6000 Device DC Operating Conditions" table on pages 31 and 33 of this data sheet. The ICCACTIVE value depends on the switching frequency and the application logic. This value is based on the amount of current that each LE typically consumes. The PIO value, which depends on the device output load characteristics and switching frequency, can be calculated using the guidelines given in Application Note 74 (Evaluating Power for Altera Devices). The ICCACTIVE value can be calculated with the following equation: A ICCACTIVE = K x fMAX x N x togLC x ----------------------------MHz x LE Where: fMAX = N = togLC = K = Maximum operating frequency in MHz Total number of LEs used in a FLEX 6000 device Average percentage of LEs toggling at each clock (typically 12.5%) Constant, shown in Table 39 Table 39. K Constant Values Altera Corporation Device K Value EPF6010A 14 EPF6016 88 EPF6016A 14 EPF6024A 14 47 FLEX 6000 Programmable Logic Device Family Data Sheet This calculation provides an ICC estimate based on typical conditions with no output load. The actual ICC should be verified during operation because this measurement is sensitive to the actual pattern in the device and the environmental operating conditions. To better reflect actual designs, the power model (and the constant K in the power calculation equations shown above) for continuous interconnect FLEX devices assumes that LEs drive FastTrack Interconnect channels. In contrast, the power model of segmented FPGAs assumes that all LEs drive only one short interconnect segment. This assumption may lead to inaccurate results, compared to measured power consumption for an actual design in a segmented interconnect FPGA. Figure 20 shows the relationship between the current and operating frequency for EPF6010A, EPF6016, EPF6016A, and EPF6024A devices. 48 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Figure 20. ICCACTIVE vs. Operating Frequency EPF6010A EPF6016 1000 200 800 150 ICC Supply Current 100 (mA) ICC Supply Current (mA) 600 400 50 200 0 50 0 100 Frequency (MHz) 30 60 Frequency (MHz) EPF6016A EPF6024A 250 400 200 300 ICC Supply 150 Current (mA) ICC Supply Current (mA) 100 200 100 50 0 50 Frequency (MHz) Device Configuration & Operation f Altera Corporation 100 0 50 100 Frequency (MHz) The FLEX 6000 architecture supports several configuration schemes to load a design into the device(s) on the circuit board. This section summarizes the device operating modes and available device configuration schemes. See Application Note 116 (Configuring APEX 20K, FLEX 10K & FLEX 6000 Devices) for detailed information on configuring FLEX 6000 devices, including sample schematics, timing diagrams, configuration options, pins names, and timing parameters. 49 FLEX 6000 Programmable Logic Device Family Data Sheet Operating Modes The FLEX 6000 architecture uses SRAM configuration elements that require configuration data to be loaded every time the circuit powers up. This process of physically loading the SRAM data into a FLEX 6000 device is known as configuration. During initialization--a process that occurs immediately after configuration--the device resets registers, enables I/O pins, and begins to operate as a logic device. The I/O pins are tri-stated during power-up, and before and during configuration. The configuration and initialization processes of a device are referred to as command mode; normal device operation is called user mode. SRAM configuration elements allow FLEX 6000 devices to be reconfigured in-circuit by loading new configuration data into the device. Real-time reconfiguration is performed by forcing the device into command mode with a device pin, loading different configuration data, reinitializing the device, and resuming usermode operation. The entire reconfiguration process requires less than 100 ms and is used to dynamically reconfigure an entire system. Also, in-field system upgrades can be performed by distributing new configuration files. Configuration Schemes The configuration data for a FLEX 6000 device can be loaded with one of three configuration schemes, which is chosen on the basis of the target application. An EPC1 or EPC1441 configuration device or intelligent controller can be used to control the configuration of a FLEX 6000 device, allowing automatic configuration on system power-up. Multiple FLEX 6000 devices can be configured in any of the three configuration schemes by connecting the configuration enable input (nCE) and configuration enable output (nCEO) pins on each device. Table 40 shows the data sources for each configuration scheme. Table 40. Configuration Schemes Configuration Scheme Data Source Configuration device EPC1 or EPC1441 configuration device Passive serial (PS) BitBlasterTM, ByteBlasterMVTM, or MasterBlasterTM download cables, or serial data source Passive serial asynchronous BitBlaster, ByteBlasterMV, or MasterBlaster (PSA) download cables, or serial data source 50 Altera Corporation FLEX 6000 Programmable Logic Device Family Data Sheet Device PinOuts Altera Corporation See the Altera web site (http://www.altera.com) or the Altera Digital Library for pin-out information. 51 FLEX 6000 Programmable Logic Device Family Data Sheet (R) 101 Innovation Drive San Jose, CA 95134 (408) 544-7000 http://www.altera.com Applications Hotline: (800) 800-EPLD Customer Marketing: (408) 544-7104 Literature Services: (888) 3-ALTERA lit_req@altera.com 52 Altera, BitBlaster, ByteBlasterMV, FastFlex, FastTrack, FineLine BGA, FLEX, MasterBlaster, MAX+PLUS II, MegaCore, MultiVolt, OptiFLEX, Quartus, SameFrame, and specific device designations are trademarks and/or service marks of Altera Corporation in the United States and other countries. Altera acknowledges the trademarks of other organizations for their respective products or services mentioned in this document, specifically: Verilog is a registered trademark of and Verilog-XL is a trademarks of Cadence Design Systems, Inc. DATA I/O is a registered trademark of Data I/O Corporation. HP is a registered trademark of HewlettPackard Company. Exemplar Logic is a registered trademark of Exemplar Logic, Inc. Pentium is a registered trademark of Intel Corporation. Mentor Graphics is a registered trademark of Mentor Graphics Corporation. OrCAD is a registered trademark of OrCAD Systems, Corporation. SPARCstation is a registered trademark of SPARC International, Inc. and is licensed exclusively to Sun Microsystems, Inc. Sun Workstation is a registered trademark of, and Sun is a registered trademark of Sun Microsystems, Inc. Synopsys is a registered trademark and DesignTime, HDL Compiler, and DesignWare are trademarks of Synopsys, Inc. VeriBest is a registered trademark of Viewlogic Systems, Inc. Viewlogic is a registered trademark of Viewlogic Systems, Inc. Altera products are protected under numerous U.S. and foreign patents and pending applications, maskwork rights, and copyrights. Altera warrants performance of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information, product, or service described herein except as expressly agreed to in writing by Altera Corporation. Altera customers are advised to obtain the latest version of device specifications before relying on any published information and before placing orders for products or services. Copyright (c) 2001 Altera Corporation. All rights reserved. Altera Corporation Printed on Recycled Paper. Altera Part Number Search Global Navigation Button Literature Global Navigation Button Licensing Altera Home Page Global Navigation Button Buy Global Navigation Button Download Entire Site On-Line Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line Results For: EPF6010A* 7 part numbers found and 0 obsolete part numbers found FLEX 6000 Device Family (5.0V) FLEX 6000 Datasheet Part Number Format Part Number Please Give Us Feedback Sign Up for E-mail Updates FLEX 6000 Literature Buying Altera Devices Device Pin & Package Temperature Speeds Options EPF6010ATC100-1 EPF6010A 100 pin TQFP Pinout EPF6010ATC100-2 EPF6010ATC100-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6010ATC144-1 EPF6010A 144 pin TQFP Pinout EPF6010ATC144-2 EPF6010ATC144-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6010ATI100-2 Industrial -2 ( -40 to 100C) EPF6010A 100 pin TQFP Pinout Search EPF6010A* Advanced None Help Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line Contact Us | New User | Site Map | Privacy | Legal Notice Copyright (c) 1995-2005 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA file:///P|/Altera Part Number Search.htm [1/11/2005 3:49:40 PM] Altera Part Number Search * Literature Licensing Buy On-Line Download Entire Site Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line Results For: EPF6016* 28 part numbers found and 3 obsolete part numbers found FLEX 6000 Device Family (5.0V) FLEX 6000 Datasheet FLEX 6000 Literature Part Number Format Buying Altera Devices Part Number Device Pin & Package Temperature Speeds Options EPF6016BC256-2 EPF6016BC256-3 EPF6016 Pinout 256 pin BGA Commercial ( 0 to 85C) -2, -3 None EPF6016QC208-2 EPF6016QC208-3 EPF6016 Pinout 208 pin PQFP Commercial ( 0 to 85C) -2, -3 None EPF6016QC240-2 EPF6016QC240-3 EPF6016 Pinout 240 pin PQFP Commercial ( 0 to 85C) -2, -3 None EPF6016QI208-3 EPF6016 Pinout 208 pin PQFP Industrial -3 ( -40 to 100C) None EPF6016TC144-2 EPF6016TC144-3 EPF6016 Pinout 144 pin TQFP Commercial ( 0 to 85C) -2, -3 None EPF6016TI144-2 EPF6016TI144-3 EPF6016 Pinout 144 pin TQFP Industrial -2, -3 ( -40 to 100C) None EPF6016AFC100-1 EPF6016AFC100-2 EPF6016AFC100-3 EPF6016A 100 pin FBGA Pinout Commercial ( 0 to 85C) -1, -2, -3 None EPF6016AFC256-1 EPF6016AFC256-2 EPF6016AFC256-3 EPF6016A 256 pin FBGA Pinout Commercial ( 0 to 85C) -1, -2, -3 None EPF6016AQC208-1 EPF6016A 208 pin PQFP EPF6016AQC208-2 Pinout EPF6016AQC208-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6016ATC100-1 EPF6016ATC100-2 EPF6016ATC100-3 EPF6016A 100 pin TQFP Pinout Commercial ( 0 to 85C) -1, -2, -3 None EPF6016ATC144-1 EPF6016ATC144-2 EPF6016ATC144-3 EPF6016A 144 pin TQFP Pinout Commercial ( 0 to 85C) -1, -2, -3 None EPF6016ATI100-2 EPF6016A 100 pin TQFP Pinout Industrial -2 ( -40 to 100C) None EPF6016ATI144-3 EPF6016A 144 pin TQFP Pinout Industrial -3 ( -40 to 100C) None file:///P|/Altera%20Part%20Number%20Search1.htm (1 of 2) [1/11/2005 3:52:56 PM] Altera Part Number Search Your search for EPF6016* found 3 obsolete part numbers. Obsolete Part Numbers Part Number Format Part Number Buying Altera Devices Last Order Date Last Ship Date Replacement Notes EPF6016AQI208-2 12/15/04 6/15/05 EPF6016AQC208-1 PDN 0314 EPF6016AQI208-3 12/15/04 6/15/05 EPF6016AQC208-2 PDN 0314 EPF6016ATI144-2 6/15/05 EPF6016ATC144-1 12/15/04 Search EPF6016* Advanced PDN 0314 Help Please Give Us Feedback Sign Up for E-mail Updates Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line Contact Us | New User | Site Map | Privacy | Legal Notice Copyright (c) 1995-2005 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA file:///P|/Altera%20Part%20Number%20Search1.htm (2 of 2) [1/11/2005 3:52:56 PM] Altera Part Number Search Literature Licensing Buy On-Line Download Entire Site Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line Results For: EPF6024A* 16 part numbers found and 2 obsolete part numbers found FLEX 6000 Device Family (5.0V) FLEX 6000 Datasheet FLEX 6000 Literature Part Number Format Buying Altera Devices Part Number Device Pin & Package Temperature Speeds Options EPF6024ABC256-1 EPF6024A 256 pin BGA EPF6024ABC256-2 Pinout EPF6024ABC256-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6024AFC256-1 EPF6024AFC256-2 EPF6024AFC256-3 EPF6024A 256 pin FBGA Pinout Commercial ( 0 to 85C) -1, -2, -3 None EPF6024AFI256-2 EPF6024A 256 pin FBGA Pinout Industrial -2 ( -40 to 100C) None EPF6024AQC208-1 EPF6024A 208 pin PQFP EPF6024AQC208-2 Pinout EPF6024AQC208-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6024AQC240-1 EPF6024A 240 pin PQFP EPF6024AQC240-2 Pinout EPF6024AQC240-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6024ATC144-1 EPF6024ATC144-2 EPF6024ATC144-3 Commercial ( 0 to 85C) -1, -2, -3 None EPF6024A 144 pin TQFP Pinout Your search for EPF6024A* found 2 obsolete part numbers. Obsolete Part Numbers Part Number Format Part Number Buying Altera Devices Last Order Date Last Ship Date Replacement Notes EPF6024ABI256-2 12/15/04 6/15/05 EPF6024ABC256-1 PDN 0314 EPF6024AQI208-3 12/15/04 6/15/05 EPF6024AQC208-2 PDN 0314 Search EPF6024A* Advanced Help Please Give Us Feedback Sign Up for E-mail Updates http://www.altera.com/cgi-bin/devsearch.pl?searc...docsetConstraints=&col=corp&qt=EPF6024A*&scope=0 (1 of 2) [1/12/2005 9:36:25 AM] Altera Part Number Search Home | Products | Support | System Solutions | Technology Center | Education & Events | Corporate | Buy On-Line Contact Us | New User | Site Map | Privacy | Legal Notice Copyright (c) 1995-2005 Altera Corporation, 101 Innovation Drive, San Jose, California 95134, USA http://www.altera.com/cgi-bin/devsearch.pl?searc...docsetConstraints=&col=corp&qt=EPF6024A*&scope=0 (2 of 2) [1/12/2005 9:36:25 AM]