General Description
The DS1863 controls and monitors all the burst-mode
transmitter and video receiver biasing functions for a
passive optical network (PON) transceiver. It has an
APC loop with tracking-error compensation that pro-
vides the reference for the laser driver’s bias current
and a temperature-indexed lookup table (LUT) that
controls the modulation current. It continually monitors
for high output current, high bias current, and low and
high transmit power with its internal fast comparators to
ensure that laser shutdown for eye safety requirements
are met without adding external components. Five ADC
channels monitor VCC, internal temperature, and three
external monitor inputs (MON1, MON2, MON3) that can
be used to meet transmitter and receive monitoring
requirements.
Applications
BPON, GPON, and GEPON Burst-Mode Transmitters
Laser Control and Monitoring
Broadband Local Access
Features
Meets BPON, GPON, and GEPON Timing
Requirements for Burst-Mode Transceivers
Bias Current Control Provided by APC Loop with
Tracking Error Compensation
Modulation Current Is Controlled by a
Temperature-Indexed Lookup Table
Supports 0dB, -3dB, -6dB Power Leveling
Settings with No Additional Calibration
Internal Direct-to-Digital Temperature Sensor
Five Analog Monitor Channels: Temperature, VCC,
MON1, MON2, and MON3
Comprehensive Fault Management System with
Maskable Laser Shutdown Capability
Two-Level Password Access to Protect
Calibration Data
120 Bytes of Password 1 (PW1) Protected
Nonvolatile Memory
128 Bytes of Password 2 (PW2) Protected
Nonvolatile Memory
I2C-Compatible Interface for Calibration and
Monitoring
Operating Voltage: 2.85V to 3.9V
Operating Temperature: -40°C to +95°C
16-Pin, Lead-Free TSSOP Package
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
______________________________________________
Maxim Integrated Products
1
19-4883; Rev 2; 8/09
For pricing, delivery, and ordering information, please contact Maxim Direct at 1-888-629-4642,
or visit Maxim’s website at www.maxim-ic.com.
+
Denotes a lead(Pb)-free/RoHS-compliant package.
T&R = Tape and reel.
Ordering Information
PART TEMP RANGE PIN-PACKAGE
DS1863E+ -40°C to +95°C 16 TSSOP
DS1863E+T&R -40°C to +95°C 16 TSSOP
16
15
14
13
12
11
10
1
2
3
4
5
6
7
VCC
BMD
MOD
BIASTX-F
N.C.
TX-D
BEN
TOP VIEW
GND
MON3
MON2SCL
SDA
98 MON1GND
FETG
TSSOP
(173 mils)
DS1863
+
Pin Configuration
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
2 _____________________________________________________________________
ABSOLUTE MAXIMUM RATINGS
RECOMMENDED OPERATING CONDITIONS
(TA= -40°C to +95°C, unless otherwise noted.)
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
Voltage on VCC, SDA and SCL Pin Relative
to Ground....................................................................-0.5V to 6V
Voltage on BEN, TX-D, TX-F, MON1–MON3,
BMD Relative to Ground...............................-0.5V to VCC + 0.5V
(subject to not exceeding +6V)
Operating Temperature Range ...........................-40°C to +95°C
Programming Temperature Range .........................0°C to +70°C
Storage Temperature Range .............................-55°C to +125°C
Soldering Temperature ...................See J-STD-020 specification
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Voltage VCC (Note 1) +2.85 3.9 V
H i gh- Level Inp ut V ol tage ( SD A, S C L, BE N) VIH:1 0.7 x VCC VCC + 0.3 V
Low- Level Inp ut V oltag e ( S DA, SC L, BE N )V
IL:1 -0.3 0.3 x VCC V
High-Level Input Voltage (TX-D) VIH:2 2.0 VCC + 0.3 V
Low-Level Input Voltage (TX-D) VIL:2 -0.3 0.8 V
ELECTRICAL CHARACTERISTICS
(VCC= +2.85V to +3.9V, TA= -40°C to +95°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Supply Current ICC (Notes 1, 2) 5 7 mA
Output Leakage (SDA, TX-F) ILO A
IOL = 4mA 0.4
Low-Level Output Voltage
(SDA, TX-F, FETG) VOL IOL = 6mA 0.6 V
High-Level Output Voltage (FETG) VOH IOH = 4mA (Note 2) VCC – 0.4 V
FETG Before Recall (Note 3) 10 100 nA
Inp ut Leakag e C ur r ent ( S C L, BE N , TX - D ) ILI:1 A
Digital Power-On Reset POD 1.0 2.2 V
Analog Power-On Reset POA 2.1 2.75 V
ANALOG INPUT CHARACTERISTICS (BMD)
(VCC = +2.85V to +3.9V, TA= -40°C to +95°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
BMD Full-Scale Voltage Range VAPC (Note 4) 2.5 V
Resolution (Note 4) 8 bits
VAPC Error TA = +25°C (Note 5) -1.75 +1.75 %FS
VAPC Integral Nonlinearity -1 +1 LSB
VAPC Differential Nonlinearity -1 +1 LSB
VAPC Temp Drift -2.5 +2.5 %FS
Input Resistance 35 50.0 65 kΩ
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
_____________________________________________________________________ 3
ANALOG OUTPUT CHARACTERISTICS
(VCC= +2.85V to +3.9V, TA= -40°C to +95°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
BIAS Current IBIAS (Note 1) 1.2 mA
IBIAS Shutdown Current IB IA S : OF F 10 100 nA
Voltage at IBIAS 0.7 1.2 1.4 V
MOD Full-Scale Voltage VMOD (Note 6) 1.25 V
MOD Output Impedance (Note 7) 3.14 kΩ
VMOD Error TA = +25°C (Note 8) -1.25 +1.25 %FS
VMOD Integral Nonlinearity -1 +1 LSB
VMOD Differential Nonlinearity -1 +1 LSB
VMOD Temperature Drift -2 +2 %FS
CONTROL LOOP AND QUICK-TRIP TIMING CHARACTERISTICS
(VCC= +2.85V to +3.9V, TA= -40°C to +95°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
First BMD Sample Following BEN tFIRST (Note 9)
Remaining Updates During BEN tREP (Note 9)
BEN High Time tBEN:HIGH 420 ns
BEN Low Time tBEN:LOW 96 ns
BIAS and MOD Turn-Off Delay tOFF s
BIAS and MOD Turn-On Delay tON s
FETG Turn-On Delay tFETG:ON s
FETG Turn-Off Delay tFETG:OFF s
Binary Search Time tSEARCH (Note 10) 5 13 BIAS
Samples
ADC Round-Robin Time tRR 65 ms
ANALOG VOLTAGE MONITORING
(VCC = +2.85V to +3.9V, TA= -40°C to +95°C, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
ADC Resolution 13 Bits
Input/Supply Accuracy
(MON1, MON2, MON3, VCC)ACC At factory setting 0.25 0.5 %FS
Update Rate for Temperature, MON1,
MON2, MON3, VCC tFRAME:1 52 70 ms
Input/Supply Offset
(MON1, MON2, MON3, VCC)VOS (Note 11) 0 5 LSB
MON1, MON2, MON3 2.5
Factory
Setting VCC Full scales are user programmable 6.5536 V
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
4 _____________________________________________________________________
NONVOLATILE MEMORY CHARACTERISTICS
(VCC = +2.85V to +3.9V, unless otherwise noted.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
EEPROM Write Cycles +70°C 50,000
I2C AC ELECTRICAL CHARACTERISTICS
(VCC = +2.85V to +3.9V, TA= -40°C to +95°C, unless otherwise noted, see Figure 9.)
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
SCL Clock Frequency fSCL (Note 12) 0 400 kHz
Clock Pulse-Width Low tLOW 1.3 µs
Clock Pulse-Width High tHIGH 0.6 µs
Bus Free Time Between STOP and
START Condition tBUF 1.3 µs
START Hold Time tHD:STA 0.6 µs
START Setup Time tSU:STA 0.6 µs
Data-In Hold Time tHD:DAT 0 0.9 µs
Data-In Setup Time tSU:DAT 100 ns
Rise Time of Both SDA and
SCL Signals tR(Note 13) 20 + 0.1CB300 ns
Fall Time of Both SDA and
SCL Signals tF(Note 13) 20 + 0.1CB300 ns
STOP Setup Time tSU:STO 0.6 µs
Capacitive Load for Each Bus Line CB(Note 13) 400 pF
EEPROM Write Time tW(Note 14) 20 ms
Note 1: All voltages are referenced to ground. Currents into the IC are positive and out of the IC are negative.
Note 2: Digital Inputs are at rail. FETG is disconnected SDA = SCL = 1.
Note 3: See the
Safety Shutdown (FETG) Output
section for details.
Note 4: Eight ranges allow the full-scale range to change from 625mV to 2.5V.
Note 5: This specification applies to the expected full-scale value for the selected range. See the Comp Ranging byte for available
full-scale ranges.
Note 6: Eight ranges allow the full-scale range to change from 312.5mV to 1.25V.
Note 7: The output impedance of the DS1863 is proportional to its scale setting. For instance, if using the 1/2 scale, the output
impedance would be 1.5kΩ.
Note 8: This specification applies to the expected full-scale value for the selected range. See the Mod Ranging byte for available
full-scale ranges.
Note 9: See the
APC/Quick-Trip Sample Timing
section for details.
Note 10: Assuming an appropriate initial step is programmed that would cause the power to exceed the APC set point within 4
steps, the bias current will be within 1% within the time specified by the binary search time.
Note 11: Guaranteed by design.
Note 12: I2C interface timing shown is for fast-mode (400kHz) operation. This device is also backward-compatible with I2C stan-
dard-mode timing.
Note 13: CB—total capacitance of one bus line in picofarads.
Note 14: EEPROM write begins after a STOP condition occurs.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
Typical Operating Characteristics
(VCC = 3.3V, TA= +25°C, unless otherwise noted.)
2.50
2.95
2.80
2.65
3.10
3.25
3.40
3.55
3.70
3.85
4.00
2.85 3.853.35 4.35 4.85 5.35
SUPPLY CURRENT vs. SUPPLY VOLTAGE
DS1863 toc01
VCC (V)
SUPPLY CURRENT (mA)
SDA = SCL = VCC
+95°C
-40°C
+25°C
3.00
3.15
3.10
3.05
3.25
3.20
3.45
3.40
3.35
3.30
3.50
-40 -20 0 20 40 60 80 100
SUPPLY CURRENT vs. TEMPERATURE
DS1863 toc02
TEMPERATURE (°C)
SUPPLY CURRENT (mA)
VCC = 2.85V
VCC = 3.9V
SDA = SCL = VCC
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
010050 150 200 250
MOD DNL
DS1863 toc03
MOD INPUT CODE (DEC)
MOD DNL (LSB)
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
0 10050 150 200 250
MOD INL
DS1863 toc04
MOD INPUT CODE (DEC)
MOD INL (LSB)
0
20
10
40
30
60
50
70
90
80
100
001 010000 011 100 101 110 111
CALCULATED AND DESIRED % CHANGE
IN VMOD vs. MOD RANGING
DS1863 toc05
MOD RANGING VALUE (DEC)
CHANGE IN VMOD (%)
DESIRED VALUE
CALCULATED VALUE
0
20
10
40
30
60
50
70
90
80
100
DESIRED AND CALCULATED CHANGE
IN VBMD vs. COMP RANGING
DS1863 toc06
COMP RANGING (DEC)
CHANGE IN VBMD (%)
001 010000 011 100 101 110 111
DESIRED VALUE
CALCULATED VALUE
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
01.00.5 1.5 2.0 2.5
MON1–3 DNL
DS1863 toc07
MON1–3 INPUT VOLTAGE (V)
MON1–3 DNL (LSB)
USING FACTORY-PROGRAMMED
FULL-SCALE VALUE OF 2.5V
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
01.00.5 1.5 2.0 2.5
MON1–3 INL
DS1863 toc08
MON1–3 INPUT VOLTAGE (V)
MON1–3 INL (LSB)
USING FACTORY-PROGRAMMED
FULL-SCALE VALUE OF 2.5V
-1.0
-0.4
-0.6
-0.8
-0.2
0
0.2
0.4
0.6
0.8
1.0
0100
50 150 200 250
VBMD INL vs. APC INDEX
DS1863 toc09
APC INDEX (DEC)
VBMD INL (LSB)
_____________________________________________________________________ 5
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
6 _____________________________________________________________________
Pin Description
PIN NAME DESCRIPTION
1 BEN Burst Enable Input. Triggers the sampling of the APC and Quick-trip monitors.
2 TX-D Transmit Disable Input. Disables BIAS and MOD outputs.
3 N.C. No Connection
4 TX-F Transmit Fault Output. Open-drain.
5 FETG Output to FET Gate. Signals an external N or P Channel MOSFET to enable/disable the lasers current.
6 SDA I2C Serial Data I/O
7 SCL I2C Serial Clock Input
8 GND Ground
9 MON1
10 MON2
11 MON3
External Analog Inputs. The voltage at these pins is digitized by the internal analog-to-digital converter
and can be read through the I2C interface. Alarm and warning values can be assigned to interrupt the
processor based on the ADC result.
12 GND Ground
13 BIAS Bias Current Output. This current DAC generates the bias current reference for the MAX3643.
14 MOD Modulation Output Voltage. This 8-bit voltage output has 8 full-scale ranges from 1.25V to 0.3125V.
This pin is connected to the MAX3643s VMSET input to control the modulation current.
15 BMD Monitor Diode Input (Feedback Voltage, Transmit Power Monitor)
16 VCC Power Supply Input
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
_____________________________________________________________________ 7
BMD
BEN
MON2
MON1
MON3
SCL
SDA
GND
VCC
TX-D
BIAS
MOD
FETG
TX-F
HBIAS QUICK
TRIP LIMIT
HTXP QUICK
TRIP LIMIT
LTXP QUICK
TRIP LIMIT
APC SETPOINT FROM
TRACKING ERROR TABLE
LATCH
ENABLE
VCC
TEMP
SENSOR
I2C
INTERFACE
SAMPLE
CONTROL
8-BIT DAC
W/SCALING DIGITAL APC
INTEGRATOR
13-BIT
DAC
ANALOG MUX
MODULATION LOOKUP
TABLE (TABLE 04h)
8-BIT DAC
W/SCALING
MAX BIAS
QUICKTRIP
INTERRUPT
MASK
INTERRUPT
LATCH
INTERRUPT
MASK
INTERRUPT
LATCH
POWER ON ANALOG
VCC > VPOA
NONMASKABLE
INTERRUPT
13-BIT
ADC
DS1863 MEMORY ORGANIZATION
SRAM RESET
RIGHT
SHIFT
TABLE 01h
EEPROM
PW1
USER MEMORY
AND ALARM
TRAPS
TABLE 02h
EEPROM
CONFIGURATION
AND
CALIBRATION
TABLE 03h
EEPROM
PW2
USER MEMORY
LOWER MEMORY
EEPROM/SRAM
ADC CONFIG/RESULTS
SYSTEM STATUS BITS
ALARM/WARNING COMPARISON RESULTS/THRESHOLDS
TABLE 04h
EEPROM
MODULATION
LUT
TABLE 05h
EEPROM
TRACKING
ERROR LUT
DIGITAL LIMIT
COMPARATOR FOR
ADC RESULTS
DS1863
MUX
MUX
MUX
Block Diagram
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
8 _____________________________________________________________________
Detailed Description
The DS1863 integrates the control and monitoring func-
tionality required to implement a PON system using
Maxims MAX3643 compact burst mode laser driver.
The compact laser driver solution offers a considerable
cost benefit by integrating control and monitoring fea-
tures in low power CMOS process, while leaving only
the high speed portions to the laser driver IC.
APC Control
BIAS current is controlled by an Average Power Control
(APC) loop. The APC loop uses digital techniques to
overcome the difficulties associated with controlling
burst mode systems.
The APC loops feedback is the monitor diode (BMD)
current, which is converted to a voltage using an exter-
nal resistor. The feedback voltage is compared to an 8-
bit scaleable voltage reference, which determines the
APC set point of the system. Scaling of the reference
voltage along with the modulation output can be uti-
lized to implement GPON power leveling.
The DS1863 has a Lookup Table to allow the APC set
point to change as a function of temperature to com-
pensate for Tracking Error (TE). The TE LUT (Table
05h), has 36 entries that determine the APC setting in
4°C windows between -40°C to +100°C.
Ranging of the APC DAC is possible by programming a
single byte in Table 02h.
Typical Operating Circuit
BEN+
BEN-
DIS
MAX3643
IN-
IN+
OUT-
BIAS-
BIAS+
MDIN
COMPACT BURST MODE
LASER DRIVER
DS1863
BURST MODE
MONITOR/CONTROL CIRCUIT
MDOUT
OUT+
VCC
TX-F
TX-D
SCL
SDA
MON2
MON3
FETG
MON1
BMD
3.3V
VMSET
MODSET
VREF
IMAX
GND
BIASSET
BENOUT
MOD
BIAS
BEN
BIASMON
VBEST
TRANSMIT POWER
RECEIVE POWER
I2C COMMUNICATION
FAULT OUTPUT
DISABLE INPUT
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
_____________________________________________________________________ 9
Modulation Control
The MOD voltage is controlled using an internal tem-
perature indexed Lookup Table.
The MOD output is an 8-bit scaleable voltage output that
interfaces with the MAX3643s VMSET input. An external
resistor to ground from the MAX3643s MODSET pin sets
the maximum current the voltage at VMSET input can
produce for a given output range. This resistor value
should be chosen to produce the maximum modulation
current the laser type requires over temperature. The
modulation LUT can be programmed in 2°C increments
over the -40°C to +102°C range to provide temperature
compensation for the lasers modulation. The modulation
DACs scaling can be used (with APC scaling) to imple-
ment GPON power leveling with a single LUT that works
for all three power levels.
Ranging of the MOD DAC is possible by programming
a single byte in Table 02h.
BIAS and MOD Output During
Initial Power-Up
On power-up the modulation and bias outputs will
remain off until VCC is above VPOA, a temperature con-
version has been completed, and if the VCC LO ADC
alarm is enabled, then a VCC conversion above the
customer defined VCC low alarm level has cleared the
VCC low alarm. Once all of these conditions are satis-
fied, the MOD output will be enabled with the value
determined by the temperature conversion and the
modulation LUT.
When the MOD output is enabled and BEN is high, the
IBIAS DAC output will be turned on to a value equal to
ISTEP (see above). The start-up algorithm checks if this
bias current causes a feedback voltage above the APC
set-point, and if it does not it continues increasing the
IBIAS by ISTEP until the APC set-point is exceeded.
When the APC set point is exceeded, the device will
begin a binary search to quickly reach the bias current
corresponding to the proper power level. After the bina-
ry search is completed the APC integrator is enabled,
and single LSB steps are taken to tightly control the
average power.
All quick-trip and ADC alarm flags are masked until the
binary search is completed. However, the BIAS MAX
alarm is monitored during this time to prevent the bias
output from exceeding MAX IBIAS. During the bias cur-
rent initialization, the bias current is not allowed to
exceed MAX IBIAS. If this occurs during the ISTEP
sequence then the binary search routine is enabled. If
MAX IBIAS is exceeded during the binary search, then
the next smaller step is activated. ISTEP or binary incre-
ments that would cause IBIAS to exceed MAX IBIAS are
not taken. Many of the alarm sources are likely to trip
1 2 3 4 5 6 7 8 9 10 11 12 13
tON
VPOA
BINARY SEARCH
APC
INTEGRATOR
ON
tSEARCH
POWER-UP TIMING
MOD
VOLTAGE
BIAS
CURRENT
VCC
BIAS
SAMPLE
ISTEP
4x ISTEP
3x ISTEP
2x ISTEP
Figure 1. DS1863 Power-Up.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
10 ____________________________________________________________________
during start-up. Masking the alarms until the completion
of the binary search prevents false alarms.
ISTEP is programmed by the customer using the Start-
up Step register. This value should be programmed to
the maximum safe current increase that is allowable
during start-up. If this value is programmed too low, the
DS1863 will still operate, but it could take significantly
longer for the algorithm to converge and hence to con-
trol the average power.
If a fault is detected, and TX-D is toggled to re-enable the
outputs, the DS1863 will power up following a similar
sequence to an initial power up. The only difference is
that the DS1863 already has determined the present tem-
perature, so the tINIT time is not required for the DS1863
to recall the APC and MOD set points from EEPROM.
BIAS and MOD Output as a Function
of Transmit Disable (TX-D)
If TX-D is asserted (logic 1) during operation, the out-
puts will immediately turn off (tOFF). When TX-D is
deasserted (logic 0), the DS1863 will turn on the MOD
output with the value associated with the present tem-
perature, and initialize the IBIAS using the same search
algorithm as done at start-up. Soft TX-D (Lower
Memory, Register 6Eh) when asserted would allow a
software control identical to the TX-D pin.
APC/Quick-Trip Shared Comparator Timing
The DS1863s input comparator is shared between the
APC control loop and the three quick-trip alarms
(HTXP, LTXP and HBIAS). The comparator polls the
alarms in a round-robin multiplexed sequence. Six of
every eight of the comparator readings will be used for
APC Loop bias current control. The other two updates
will be used to check the HTXP/LTXP (Monitor Diode
voltage) and the HBIAS (MON1) signals against the
internal APC and BIAS reference. The HTXP/LTXP com-
parison will check HTXP if the last bias-update compar-
ison was above the APC set-point, and LTXP if the last
bias update comparison was below the APC set-point.
The DS1863 has a programmable comparator sample
time based on an internally generated clock to facilitate a
wide variety of external filtering options suitable for burst
mode transmitter data rates between 155Mbits/s and
1250Mbits/s. The rising edge of burst enable (BEN) trig-
gers the sample to occur, and the Sample Rate register
determines the delay. The internal clock is asynchronous
to BEN, causing a 100ns uncertainty as to when the first
sample will occur following BEN. After the first sample
occurs, subsequent samples will occur on a regular
interval. The following sample rate options are available.
Comparisons of the HTXP, LTXP, and HBIAS quick-trip
alarms will not occur during the burst enable low time.
Any quick-trip alarm that is detected will by default
remain active until a subsequent comparator sample
shows the condition no longer exists.
A second bias current monitor compares the DS1863s
bias current DACs code to a digital value stored in the
MAX IBIAS register. This comparison is made every
bias current update to ensure that a high bias current
will be quickly detected.
TX-D TIMING (NORMAL OPERATION)
TX-D
IBIAS
IMOD tOFF tON
tON
tOFF
Figure 2. TX-D Timing (Output Disabled During Normal Operating
Conditions).
SR3SR0
MINIMUM TIME
FROM BEN TO FIRST
SAMPLE (tFIRST)
±50ns
REPEATED SAMPLE
PERIOD FOLLOWING
0000b 350ns 800ns
0001b 550ns 1200ns
0010b 750ns 1600ns
0011b 950ns 2000ns
0100b 1350ns 2800ns
0101b 1550ns 3200ns
0110b 1750ns 3600ns
0111b 2150ns 4400ns
1000b 2950ns 6000ns
1001b* 3150ns 6400ns
*All codes greater than 1001b (1010b–111b) use the maximum
sample time of code 1001b.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 11
Monitors And Fault Detection
Monitors
Monitoring functions on the DS1863 include four quick-
trip comparators and five ADC channels
This monitoring combined with the interrupt masks
determines when/if the DS1863 shuts down its outputs
and triggers the TX-F and FETG outputs. All of the mon-
itoring levels and interrupt masks are user programma-
ble with the exception of POA, which trips at a fixed
range and is non-maskable for safety reasons.
Four Quick-Trip Monitors And Alarms
Four quick-trip monitors are provided to detect potential
laser safety issues. These monitor
1) High Bias Current (HBIAS)
2) Low Transmit Power (LTXP)
3) High Transmit Power (HTXP)
4) Max Output Current (MAX IBIAS)
The high and low transmit power quick-trip registers
(HTXP and LTXP) set the thresholds used to compare
against the BMD voltage to determine if the transmit
power is within specification. The HBIAS quick-trip
compares the MON1 input (generally from the
MAX3643 bias monitor output) against its threshold set-
ting to determine if the present bias current is above
specification. The Max Bias quick-trip is a digital com-
parison that determines if the Bias Output code indi-
cates the bias current is above specification. The bias
current will not be allowed to exceed the value set in
this register. When the DS1863 detects the bias is at
the limit it will set the BIAS MAX status bit and hold the
bias current at the MAX IBIAS level. The quick-trips are
routed to the TX-F and FETG outputs via interrupt
masks to allow combinations of these alarms to be
used to trigger these outputs. Any time FETG is trig-
gered the DS1863 will also disable its outputs. All the
quick-trip alarm levels and masks are programmable
through the I2C interface.
Five ADC Monitors And Alarms
The ADC monitors five channels that measure tempera-
ture (internal temp sensor), VCC, MON1, MON2, and
MON3 using an analog multiplexer to measure them
round robin with a single ADC. Each channel has a
customer programmable full scale range and offset
value that will be factory programmed to default value
(see below). Additionally, MON1, MON2, and MON3
have the ability to right shift results by up to 7 bits
before the results are compared to alarm thresholds or
read over the I2C bus. This allows customers with spec-
ified ADC ranges to calibrate the ADC full scale to a
factor of 1/2nof their specified range to measure small
signals. The DS1863 can then right shift the results by n
bits to maintain the bit weight of their specification.
The ADC results (after right shifting, if used) are com-
pared to high alarm thresholds (to check if the results
exceeded this threshold), the low alarm thresholds (to
check if the ADC results are below this threshold) and
the warning threshold after each conversion (20 com-
parisons total), and the corresponding alarms are set
which can be used to trigger the TX-F or FETG outputs.
These ADC thresholds are user programmable via the
I2C interface, as are the masking registers that can be
APC LOOP/QUICK TRIP SAMPLE TIMING
LAST BURST'S
BIAS SAMPLE
BEN
BIAS DAC
CODE
QUICK-TRIP
SAMPLE TIMES
HBIAS
SAMPLE
tFIRST
tREP
H/LTXP
SAMPLE
BIAS
SAMPLE
BIAS
SAMPLE
BIAS
SAMPLE
BIAS
SAMPLE
BIAS
SAMPLE
BIAS
SAMPLE
BIAS
SAMPLE
Figure 3. APC/Quick-Trip Alarm Sample Timing.
ADC Default Monitor Full Scale Ranges
SIGNAL (UNITS)
+ FS
SIGNAL
+ FS
HEX
- FS
SIGNAL
- FS
HEX
Temperature (oC)
127.996
7FFF -128 8000
VCC (V)
6.5528
FFF8 0V 0000
MON1, MON2,
MON3 (V)
2.4997
FFF8 0V 0000
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
12 ____________________________________________________________________
used to prevent the alarms from triggering the TX-F and
FETG outputs. See below for more detail on the TX-F
and FETG outputs.
ADC Timing
There are five analog channels that are digitized in a
round robin fashion in the order shown in Figure 4. The
total time required to convert all five channels is tRR
(see electrical specifications for details).
Right Shifting A/D Conversion Result
If the weighting of the ADC digital reading must con-
form to a Predetermined Full-Scale (PFS) value defined
by a specification, then right shifting can be used to
adjust the PFS analog measurement range while main-
taining the weighting of the ADC results. The DS1863s
range is wide enough to cover all requirements; when
maximum input value is far short of the FS value, right
shifting can be used to obtain greater accuracy. For
instance, the maximum voltage might be 1/8 of the
specified PFS value, so only 1/8 of the converters
range is effective over this range. An alternative is to
calibrate the ADCs full scale range to 1/8 the readable
PFS value and use a right-shift value of 3. With this
implementation, the resolution of the measurement has
increased by a factor of 8, and because the result is
digitally divided by 8 by right shifting, the bit weight of
the measurement still meets the standard.
The right shift operation on the A/D converter results is
carried out based on the contents of Right Shift Control
Registers (Table 02h Registers 8Eh to 8Fh) in EEPROM.
Three analog channels: MON1 to MON3 each have 3
bits allocated to set the number of right shifts. Up to 7
right shift operations are allowed and will be executed
as a part of every conversion before the results are
compared to the high and low alarm levels, or loaded
into their corresponding measurement registers 62h to
69h. This is true during the setup of internal calibration
as well as during subsequent data conversions.
Transmit Fault (TX-F) Output
The TX-F output has masking registers for the five ADC
alarms and the four QT alarms to select which compar-
isons cause it to assert. In addition, the FETG alarm is
selectable via the TX-F mask to cause TX-F to assert.
All alarms, with the exception of FETG, will only cause
TX-F to remain active while the alarm condition persists.
However, the TX-F latch bit can enable the TX-F output
to remain active until it is cleared by the TX-F reset bit,
TX-D, soft TX-D, or by power cycling the part. If the
FETG output is configured to trigger TX-F, then it is indi-
cating that the DS1863 is in shutdown, and will require
TX-D, soft TX-D, or cycling power to reset. The ADC
and Quick-trip alarms (with the exception of BIAS MAX)
are ignored for the first 8-10 bias current updates dur-
ing power up. Only enabled alarms will activate TX-F.
The following table shows TX-F as a function of TX-D
and the alarm sources.
Safety Shutdown (FETG) Output
The FETG output has masking registers (separate from
TX-F) for the five ADC alarms and the four QT alarms to
select which comparisons cause it to assert. Unlike TX-F,
NORMAL ADC SAMPLE TIMING
TEMP VCC MON1 MON2 MON3 TEMP VCC
ONE ROUND-ROBIN ADC CYCLE
MON3
tRR
Figure 4. ADC Round-Robin Timing.
If VCC low alarm is set for either the TX-F or FETG output, the Round Robin timing will cycle between only TEMP and VCC.
TX-F as a Function of TX-D and Alarm
Sources
VCC > VPOA
TX-D
NON-MASKED
TX-F ALARM
TX-F
No X X 1
Yes 0 0 0
Yes 0 1 1
Yes 1 X 0
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 13
FETG output is always latched in case it is triggered by
an unmasked alarm condition. Its output polarity is pro-
grammable to allow an external N or P MOSFET to open
during alarms to shut off the laser diode current. If the
FETG output triggers indicating the DS1863 is in shut-
down, then it requires TX-D, soft TX-D, or cycling power
to be reset. Under all conditions when the analog outputs
are re-initialized after being disabled, all the alarms with
the exception of the VCC low ADC alarm will be cleared.
The VCC low alarm must remain active to prevent the out-
put from attempting to operate when inadequate VCC
exists to operate the laser driver. Once adequate VCC is
present to clear the VCC low alarm, the outputs will be
enabled following the same sequence as power up.
As mentioned before the FETG is an output used to dis-
able the laser current via a series N or P MOSFET. This
requires that the FETG output is capable of sinking or
sourcing current. Because the DS1863 will not know if it
should sink or source current before VCC exceeds
VPOA, which triggers the EE recall, this output will be
high impedance when VCC is below VPOA. (see Low
Voltage Operation section for details and diagram).
The application circuit must use a pull-up or pull-down
resistor on this pin that pulls FETG to the alarm/shut-
down state (high for a PMOS, low for a NMOS). Once
VCC is above VPOA, the DS1863 will pull the FETG out-
put to the state determined by the FETG DIR bit (Table
02h, Register 89h). FETG DIR will be 0 if an NMOS is
used and 1 if a PMOS is used.
Determining Alarm Causes
Using The I2C Interface
To determine the cause of the TX-F or FETG alarm, the
system processor can read the DS1863s Alarm Trap
Bytes (ATB) through the I2C interface (in Table 01h). The
ATB have a bit for each alarm. Any time an alarm occurs,
regardless of the mask bits state, the DS1863 sets the
corresponding bit in the ATB. Active ATB bits will remain
set until written to zeros via the I2C interface. On power
up the ATB will be zeros until alarms dictate otherwise.
Die Identification
DS1863 will have an ID hard coded to its die. Two reg-
isters (Table 02h bytes 86h87h) are assigned for this
feature. Byte 86h will read 63h to identify the part as the
DS1863, byte 87h will read to A1h (for A1 die revision).
Low-Voltage Operation
The DS1863 contains two Power-On Reset (POR) lev-
els. The lower level is a Digital POR (VPOD) and the
TX-F LATCHED OPERATION
TX-F NON-LATCHED OPERATION
DETECTION OF
TX-F FAULT
TX-D OR
TX-F RESET
TX-F
DETECTION OF
TX-F FAULT
TX-F
Figure 5. DS1863 TX-F Timing.
FETG and MOD and BIAS Outputs as a
Function of TX-D and Alarm Sources
VCC >
VPOA
TX-D
NON-MASKED
FETG ALARM
FETG
MOD AND
BIAS
OUTPUTS
Yes 0 0
FETG DIR
Enabled
Yes 0 1
FETG DIR
Disabled
Yes 1 X
FETG DIR
Disabled
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
14 ____________________________________________________________________
higher level is an Analog POR (VPOA). At start up,
before the supply voltage rises above VPOA, the out-
puts are disabled (FETG and BIAS outputs are high
impedance, MOD is low), all SRAM outputs are low
(including Shadowed EEPROM), and all analog circuit-
ry is disabled. When VCC reaches VPOA, the SEE is
recalled, and the analog circuitry is enabled. While
VCC remains above VPOA, the device is in its normal
operating state, and it responds based on its non-
volatile configuration. If during operation VCC falls
below VPOA, but is still above VPOD, then the SRAM
will retain the SEE settings from the first SEE recall, but
the device analog will be shut down and the outputs
disabled. FETG will be driven to its alarm state defined
by the FETG DIR bit (Table 02h, Register 89h). If the
supply voltage recovers back above VPOA, then the
device will immediately resume normal functioning. If
the supply voltage falls below VPOD, then the device
SRAM will be placed in its default state and another
SEE recall will be required to reload the nonvolatile set-
tings. The EEPROM recall will occur the next time VCC
next exceeds VPOA. Figure 7 shows the sequence of
events as the voltage varies.
Any time VCC is above VPOD, the I2C interface can be
used to determine if VCC is below the VPOA level. This
is accomplished by checking the RDYB bit in the Status
(6Eh) byte. RDYB is set when VCC is below VPOA; when
VCC rises above VPOA RDYB is timed (within 500µs) to
go to 0, at which point the part is fully functional.
For all Device Addresses sourced from EEPROM (Byte
8Ch, Table 01h in memory) the default Device Address
is A2h until VCC exceeds VPOA allowing the device
address to be recalled from the EEPROM.
Power-On Analog (POA)
POA holds the DS1863 in reset until VCC is at a suitable
level (VCC > VPOA) for the part to accurately measure
with its ADC and compare analog signals with its quick-
trip monitors. Because VCC cannot be measured by the
ADC when VCC is less than VPOA, POA also asserts the
VCC low alarm, which must be cleared by a VCC ADC
conversion that is greater than the customer programma-
ble VCC low ADC limit. This prevents the TX-F and FETG
outputs from glitching during a slow power up. The TX-F
and FETG output will not latch until there is a conversion
above VCC low limit.
The POA alarm is non-maskable. The TX-F, and FETG
outputs shuts off any time VCC is below VPOA. See Low
Voltage Operation section for more information.
FETG/OUTPUT DISABLE TIMING (FAULT CONDITION DETECTED)
IBIAS
IMOD
DETECTION OF
FETG FAULT
tOFF tON
tON
tOFF
TX-D
tFETG:ON
FETG tFETG:OFF
Figure 6. FETG/Modulation and Bias Timing (Fault Condition Detected).
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 15
DS1863 Memory Map
Memory Organization
The DS1863 features six memory banks that include the
following.
The Lower Memory is addressed from 00h to 7Fh and
contains alarm and warning thresholds, flags, masks,
several control registers, password entry area (PWE),
and the Table Select byte. The Table Select Byte deter-
mines which Table (01h05h) will be mapped into the
upper memory locations.
Table 01h primarily contains user EEPROM (with PW1
level access) as well as some Alarm and Warning sta-
tus bytes.
Table 02h is a multifunction space that contains
Configuration registers, scaling and offset values,
Passwords, interrupt registers as well as other miscella-
neous control bytes.
Table 03h is strictly user EEPROM that is protected by
a PW2 level password.
Table 04h contains a temperature indexed Look up
Table (LUT) for control of the modulation voltage. The
modulation LUT can be programmed in 2°C increments
over the -40°C to +102°C range. Access to this register
is protected by a PW2 level password.
Table 05h contains another LUT which allows the APC
set point to change as a function of temperature to
compensate for Tracking Error (TE). This TE LUT, has
36 entries that determine the APC setting in 4°C win-
dows between -40°C to 100°C. Access to this register
is protected by a PW2 level password.
Complete detail of each bytes function, as well as
Read/Write permissions for each Byte for each table is
provided in the Register Descriptions sections.
Shadowed EEPROM
Many nonvolatile (NV) memory locations (listed within
the Detailed Register Description section) are actually
Shadowed-EEPROM which are controlled by the SEEB
bit in Table 02h, Byte 80h.
The DS1863 incorporates Shadowed EEPROM memory
locations for key memory addresses that may be re-
written many times. By default the Shadowed EEPROM
Bit, SEEB, is not set and these locations act as ordinary
EEPROM. By setting SEEB these locations function like
SRAM cells, which allow an infinite number of write
cycles without concern of wearing out the EEPROM.
This also eliminates the requirement for the EEPROM
write time, tWR. Because changes made with SEEB
enabled do not affect the EEPROM, these changes are
not retained through power cycles. The power-up value
is the last value written with SEEB disabled. This func-
tion can be used to limit the number of EEPROM writes
during calibration or to change the monitor thresholds
periodically during normal operation helping to reduce
the number of times EEPROM is written. The Memory
Map description indicates which locations are shad-
owed-EEPROM.
VCC
VPOA
VPOD
FETG
SEE*
HIGH
IMPEDANCE
HIGH
IMPEDANCE
HIGH
IMPEDANCE
NORMAL
OPERATION
DRIVEN TO
FETG DIR
NORMAL
OPERATION
PRECHARGED
TO 0
PRECHARGED
TO 0
PRECHARGED
TO 0
RECALLED
VALUE
RECALLED
VALUE
DRIVEN TO
FETG DIR
NORMAL
OPERATION
DRIVEN TO
FETG DIR
SEE RECALL SEE RECALL
Figure 7. DS1863 Digital and Analog Power-On Reset.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
16 ____________________________________________________________________
I2C Definitions
Master Device: The master device controls the slave
devices on the bus. The master device generates SCL
clock pulses, START and STOP conditions.
Slave Devices: Slave devices send and receive data
at the masters request.
Bus Idle or Not Busy: Time between STOP and START
conditions when both SDA and SCL are inactive and in
their logic-high states. When the bus is idle it often initi-
ates a low-power mode for slave devices.
START Condition: A START condition is generated by
the master to initiate a new data transfer with a slave.
Transitioning SDA from high to low while SCL remains
high generates a START condition. See the timing dia-
gram for applicable timing.
STOP Condition: A STOP condition is generated by
the master to end a data transfer with a slave.
Transitioning SDA from low to high while SCL remains
high generates a STOP condition. See the timing dia-
gram for applicable timing.
Repeated START Condition: The master can use a
repeated START condition at the end of one data trans-
fer to indicate that it will immediately initiate a new data
transfer following the current one. Repeated STARTS
are commonly used during read operations to identify a
TABLE SELECT BYTE
MISC. CONTROL BITS
PASSWORD ENTRY (PWE)
(4 BYTES)
DIGITAL DIAGNOSTIC
FUNCTIONS
7Fh
I2C SLAVE ADDRESS A2h
00h
FFh
80h
PW1 LEVEL ACCESS
EEPROM
(120 BYTES)
TABLE 01h
LOWER MEMORY
FFh
F7h
80h
C0h
CONFIGURATION AND
CONTROL
EMPTY
TABLE 02h
FFh
80h
PW2 LEVEL ACCESS
EEPROM
(128 BYTES)
TABLE 03h
C7h
80h
MODULATION VOLTAGE
CONTROL TEMPERATURE
INDEXED LUT
TABLE 04h
A7h
80h
TRACKING ERROR LUT
FOR TEMPERATURE
INDEXED CONTROL OF
APC SET-POINT
TABLE 05h
DEC
0
HEX
0
127 7F
128 80
248 F8
255 FF
Figure 8. DS1863 Memory Map.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 17
specific memory address to begin a data transfer. A
repeated START condition is issued identically to a nor-
mal START condition. See the timing diagram for
applicable timing.
Bit Write: Transitions of SDA must occur during the low
state of SCL. The data on SDA must remain valid and
unchanged during the entire high pulse of SCL plus the
setup and hold-time requirements (Figure 9). Data is shift-
ed into the device during the rising edge of the SCL.
Bit Read: At the end of a write operation, the master
must release the SDA bus line for the proper amount of
setup time before the next rising edge of SCL during a
bit read. The device shifts out each bit of data on SDA at
the falling edge of the previous SCL pulse and the data
bit is valid at the rising edge of the current SCL pulse.
Remember that the master generates all SCL clock
pulses including when it is reading bits from the slave.
Acknowledgement (ACK and NACK): An Acknowledge-
ment (ACK) or Not Acknowledge (NACK) is always the
9th bit transmitted during a byte transfer. The device
receiving data (the master during a read or the slave
during a write operation) performs an ACK by transmit-
ting a zero during the 9th bit. A device performs a
NACK by transmitting a one during the 9th bit. Timing
for the ACK and NACK is identical to all other bit writes.
An ACK is the acknowledgment that the device is prop-
erly receiving data. A NACK is used to terminate a read
sequence or as an indication that the device is not
receiving data.
Byte Write: A byte write consists of 8 bits of information
transferred from the master to the slave (most signifi-
cant bit first) plus a 1-bit acknowledgement from the
slave to the master. The 8 bits transmitted by the mas-
ter are done according to the bit write definition and the
acknowledgement is read using the bit read definition.
Byte Read: A byte read is an 8-bit information transfer
from the slave to the master plus a 1-bit ACK or NACK
from the master to the slave. The 8 bits of information
that are transferred (most significant bit first) from the
slave to the master are read by the master using the bit
read definition, and the master transmits an ACK using
the bit write definition to receive additional data bytes.
The master must NACK the last byte read to terminate
communication so the slave will return control of SDA to
the master.
Slave Address Byte: Each slave on the I2C bus
responds to a slave addressing byte (Figure 10) sent
immediately following a START condition. The slave
address byte contains the slave address in the most sig-
nificant 7 bits and the R/Wbit in the least significant bit.
The DS1863s slave address can be configured to any
value between 00h to FEh using the Device Address
Byte (Table 02h, Register 8Ch). The user also has to set
the ASEL bit (Table 02h, Register 89h) for this address to
be active. The default address is A2h (see Figure 10). By
writing the correct slave address with R/W= 0, the mas-
ter indicates it will write data to the slave. If R/W= 1, the
master will read data from the slave. If an incorrect slave
address is written, the DS1863 will assume the master is
communicating with another I2C device and ignore the
communications until the next START condition is sent.
Memory Address: During an I2C write operation, the
master must transmit a memory address to identify the
memory location where the slave is to store the data.
The memory address is always the second byte trans-
mitted during a write operation following the slave
address byte.
SDA
SCL
tHD:STA
tLOW
tHIGH
tRtF
tHD:DAT
tSU:DAT REPEATED
START
tSU:STA
tHD:STA
tSU:STO
tSP
STOP START
tBUF
NOTE: TIMING IS REFERENCED TO VIL(MAX) AND VIH(MIN).
Figure 9. I2C Timing Diagram.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
18 ____________________________________________________________________
I2C Communication
Writing a Single Byte to a Slave: The master must
generate a START condition, write the slave address
byte (R/W= 0), write the byte of data, and generate a
STOP condition. The master must read the slaves
acknowledgement during all byte write operations.
Writing Multiple Bytes to a Slave: To write multiple
bytes to a slave, the master generates a start condition,
writes the slave address byte (R/W= 0), writes the
memory address, writes up to 8 data bytes, and gener-
ates a stop condition. The DS1863 writes 1 to 8 bytes (1
page or row) with a single write transaction. This is
internally controlled by an address counter that allows
data to be written to consecutive addresses without
transmitting a memory address before each data byte is
sent. The address counter limits the write to one 8-byte
page (one row of the memory map). Attempts to write to
additional pages of memory without sending a stop
condition between pages results in the address counter
wrapping around to the beginning of the present row.
Example: A 3-byte write starts at address 06h and
writes three data bytes (11h, 22h, and 33h) to three
consecutive addresses. The result is that addresses
06h and 07h would contain 11h and 22h, respectively,
and the third data byte, 33h, would be written to
address 00h.
To prevent address wrapping from occurring, the mas-
ter must send a stop condition at the end of the page,
then wait for the bus-free or EEPROM-write time to
elapse. Then the master can generate a new start con-
dition, and write the slave address byte (R/W= 0) and
the first memory address of the next memory row
before continuing to write data.
Acknowledge Polling: Any time an EEPROM location
is written, the DS1863 requires the EEPROM write time
(tW) after the STOP condition to write the contents of
the byte of data to EEPROM. During the EEPROM write
time, the device will not acknowledge its slave address
because it is busy. It is possible to take advantage of
that phenomenon by repeatedly addressing the
DS1863, which allows the next page to be written as
soon as the DS1863 is ready to receive the data. The
alternative to acknowledge polling is to wait for a maxi-
mum period of tWto elapse before attempting to write
again to the device.
EEPROM Write Cycles: When EEPROM writes occur to
the memory, the DS1863 will write to all three EEPROM
memory locations, even if only a single byte was modi-
fied. Because all three bytes are written, the bytes that
were not modified during the write transaction are still
subject to a write cycle. This can result in all three bytes
being worn out over time by writing a single byte repeat-
edly. The DS1863s EEPROM write cycles are specified in
the NV Memory Characteristics table. The specification
shown is at the worst-case temperature. If zero-crossing
detection is enabled, EEPROM write cycles cannot begin
until after the zero-crossing detection is complete.
Reading a Single Byte from a Slave: To read a single
byte from the slave, the master generates a START con-
dition, writes the slave address byte with R/W= 1, reads
the data byte with a NACK to indicate the end of the
transfer, and generates a STOP condition. When a single
byte is read, it will always be the Potentiometer 0 value.
Reading Multiple Bytes from a Slave: The read oper-
ation can be used to read multiple bytes with a single
transfer. When reading bytes from the slave, the master
simply ACKs the data byte if it desires to read another
byte before terminating the transaction. After the mas-
ter reads the last byte, it NACKs to indicate the end of
the transfer and generates a STOP condition. The first
byte read will be the Potentiometer 0 Wiper Setting. The
next byte will be the Potentiometer 1 Wiper Setting. The
third byte is the Configuration Register byte. If an ACK
is issued by the master following the Configuration
Register byte, then the DS1863 will send the
Potentiometer 0 Wiper Setting again. This round robin
reading will occur as long as each byte read is followed
by an ACK from the master.
THE DEFAULT SLAVE ADDRESS IS SHOWN, HOWEVER IT CAN BE CHANGED
USING THE DEVICE ADDRESS BYTE (TABLE 02h, BYTE 8Ch)., AND ASEL BIT.
1
MSB
SLAVE
ADDRESS*
LSB
010001
R/W
READ/WRITE
BIT
Figure 10. DS1863 Slave Address Byte (Default)
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 19
LOWER MEMORY
WORD 0 WORD 1 WORD 2 WORD 3
ROW
(HEX)
ROW
NAME BYTE 0/8 BYTE 1/9
BYTE 2/A BYTE 3/B BYTE 4/C BYTE 5/D BYTE 6/E
BYTE 7/F
00
<1>THRESHOLD0
TEMP ALARM HI TEMP ALARM LO TEMP WARN HI TEMP WARN LO
08
<1>THRESHOLD1
VCC ALARM HI VCC ALARM LO VCC WARN HI VCC WARN LO
10
<1>THRESHOLD2
MON1 ALARM HI MON1 ALARM LO MON1 WARN HI MON1 WARN LO
18
<1>THRESHOLD3
MON2 ALARM HI MON2 ALARM LO MON2 WARN HI MON2 WARN LO
20
<1>THRESHOLD4
MON3 ALARM HI MON3 ALARM LO MON3 WARN HI MON3 WARN LO
28
<1>SHADOWED EE
SEE SEE SEE SEE SEE SEE SEE SEE
30 <1>PW2 EE EE EE EE EE EE EE EE EE
38 <1>PW2 EE EE EE EE EE EE EE EE EE
40 <1>PW2 EE EE EE EE EE EE EE EE EE
48 <1>PW2 EE EE EE EE EE EE EE EE EE
50 <1>PW2 EE EE EE EE EE EE EE EE EE
58 <1>PW2 EE EE EE EE EE EE EE EE EE
60
<2>ADC VALUES0
TEMP VALUE VCC VALUE MON1 VALUE MON2 VALUE
68
<0> ADC VALUES1
<2>MON3 VALUE <2>RESERVED <2>RESERVED
<0>STATUS
<3>UPDATE
70
<2>ALARM/WARN
ALARM3ALARM2ALARM1
ALARM0
WARN3WARN2RESERVED
78
<0>TABLE SELECT <6>RESERVED <6>RESERVED <6>RESERVED
<6>PWE MSB <6>PWE LSB
<5>TBL SEL
Access Code <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <10> <11>
Read Access All All All PW2 All N/A PW1 PW2 N/A PW2 All
Write Access
S ee each
b i t /b yt e
s ep ar at el y PW2 N/A Al l and
DS1863
Har dwar e
PW2 +
mode bit
All All PW1 PW2 PW2 N/A PW1
Lower Memory Register Map
This register map shows each byte/word in terms of the
row it is on in the memory. The first byte in the row is
located in memory at the row address (hexadecimal) in
the left most column. Each subsequent byte on the row is
one/ two memory locations beyond the previous
byte/words address. A total of eight bytes are present
on each row. For more information about each of these
bytes see the corresponding register description.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
20 ____________________________________________________________________
Table 01h. Register Map
TABLE 01h (PW1)
WORD 0 WORD 1 WORD 2 WORD 3
ROW
(HEX)
ROW
NAME
BYTE 0/8 BYTE 1/9 BYTE 2/A BYTE 3/B BYTE 4/C BYTE 5/D BYTE 6/E
BYTE 7/F
80 <7>PW1 EE EE EE EE EE EE EE EE EE
88 <7>PW1 EE EE EE EE EE EE EE EE EE
90 <7>PW1 EE EE EE EE EE EE EE EE EE
98 <7>PW1 EE EE EE EE EE EE EE EE EE
A0
<7>PW1 EE EE EE EE EE EE EE EE EE
A8
<7>PW1 EE EE EE EE EE EE EE EE EE
B0
<7>PW1 EE EE EE EE EE EE EE EE EE
B8
<7>PW1 EE EE EE EE EE EE EE EE EE
C0
<7>PW1 EE EE EE EE EE EE EE EE EE
C8
<7>PW1 EE EE EE EE EE EE EE EE EE
D0
<7>PW1 EE EE EE EE EE EE EE EE EE
D8
<7>PW1 EE EE EE EE EE EE EE EE EE
E0
<7>PW1 EE EE EE EE EE EE EE EE EE
E8
<7>PW1 EE EE EE EE EE EE EE EE EE
F0 <7>PW1 EE EE EE EE EE EE EE EE EE
F8
<11>ALARM TRAP ALARM3ALARM2ALARM1ALARM0
WARN3WARN2RESERVED
Access Code <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <10> <11>
Read Access All All All PW2 All N/A PW1 PW2 N/A PW2 All
Write Access
S ee each
b i t /b yt e
s ep ar at el y PW2 N/A Al l and
DS1863
Har dwar e
PW2 +
mode bit
All All PW1 PW2 PW2 N/A PW1
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 21
Table 02h. Register Map
TABLE 02h (PW2)
WORD 0 WORD 1 WORD 2 WORD 3
ROW
(HEX)
ROW
NAME BYTE 0/8 BYTE 1/9 BYTE 2/A BYTE 3/B
BYTE 4/C BYTE 5/D
BYTE 6/E BYTE 7/F
80
<0>CONFIG0
<8>MODE
<4>TINDEX <4>MOD DAC <4>APC DAC < 4>
BIAS DAC2< 4>
BIAS DAC2< 10 >
DEV ICE ID
<10>DEVICE VER
88
<8>CONFIG1
UPDATE
RATE CONFIG START-UP
STEP
MOD
RANGING
DEVICE
ADDRESS
COMP
RANGING
RSHIFT1RSHIFT0
90 <8>SCALE0RESERVED VCC SCALE MON1 SCALE MON2 SCALE
98 <8>SCALE1MON3 SCALE RESERVED RESERVED RESERVED
A0
<8>OFFSET0
RESERVED VCC OFFSET MON1 OFFSET MON2 OFFSET
A8
<8>OFFSET1
MON3 OFFSET RESERVED RESERVED
INTERNAL TEMP OFFSET*
B0
< 9>
P WD V ALU E
PW1 MSB PW1 LSB PW2 MSB PW2 LSB
B8
<8>INTERRUPT FETG EN1FETG EN0
TX-F EN1TX-F EN0HTXP LTXP HBIAS
MAX IBIAS
C0-F7
EMPTY EMPTY EMPTY EMPTY EMPTY EMPTY EMPTY EMPTY EMPTY
F8
<4>MAN IBIAS MAN IBIAS0MAN IBIAS1MAN_CNTL RESERVED RESERVED RESERVED RESERVED
RESERVED
Access Code <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <10> <11>
Read Access All All All PW2 All N/A PW1 PW2 N/A PW2 All
Write Access
S ee each
b i t /b yt e
s ep ar at el y PW2 N/A Al l and
DS1863
Har dwar e
PW2 +
mode bit
All All PW1 PW2 PW2 N/A PW1
*The Final Result must be XOR’ed with BB40h before writing to this register.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
22 ____________________________________________________________________
Table 03h. Register Map
TABLE 03h (PW2)
WORD 0 WORD 1 WORD 2 WORD 3
ROW
(HEX)
ROW
NAME
BYTE 0/8 BYTE 1/9 BYTE 2/A BYTE 3/B BYTE 4/C BYTE 5/D BYTE 6/E
BYTE 7/F
80 <8>PW2 EE EE EE EE EE EE EE EE EE
88 <8>PW2 EE EE EE EE EE EE EE EE EE
90 <8>PW2 EE EE EE EE EE EE EE EE EE
98 <8>PW2 EE EE EE EE EE EE EE EE EE
A0
<8>PW2 EE EE EE EE EE EE EE EE EE
A8
<8>PW2 EE EE EE EE EE EE EE EE EE
B0
<8>PW2 EE EE EE EE EE EE EE EE EE
B8
<8>PW2 EE EE EE EE EE EE EE EE EE
C0
<8>PW2 EE EE EE EE EE EE EE EE EE
C8
<8>PW2 EE EE EE EE EE EE EE EE EE
D0
<8>PW2 EE EE EE EE EE EE EE EE EE
D8
<8>PW2 EE EE EE EE EE EE EE EE EE
E0
<8>PW2 EE EE EE EE EE EE EE EE EE
E8
<8>PW2 EE EE EE EE EE EE EE EE EE
F0 <8>PW2 EE EE EE EE EE EE EE EE EE
F8 <8>PW2 EE EE EE EE EE EE EE EE EE
Access Code <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <10> <11>
Read Access All All All PW2 All N/A PW1 PW2 N/A PW2 All
Write Access
S ee each
b i t /b yt e
s ep ar at el y PW2 N/A Al l and
DS1863
Har dwar e
PW2 +
mode bit
All All PW1 PW2 PW2 N/A PW1
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 23
Table 04h. Register Map
TABLE 04h (LUT FOR MOD)
WORD 0 WORD 1 WORD 2 WORD 3
ROW
(HEX)
ROW
NAME
BYTE 0/8 BYTE 1/9 BYTE 2/A BYTE 3/B BYTE 4/C BYTE 5/D BYTE 6/E
BYTE 7/F
80 <8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
88 <8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
90 <8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
98 <8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
A0
<8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
A8
<8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
B0
<8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
B8
<8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
C0
<8>LUT4 MOD MOD MOD MOD MOD MOD MOD MOD
Table 05h. Register Map
TABLE 05h (LUT FOR APC)
WORD 0 WORD 1 WORD 2 WORD 3
ROW
(HEX)
ROW
NAME
BYTE 0/8 BYTE 1/9 BYTE 2/A BYTE 3/B BYTE 4/C BYTE 5/D BYTE 6/E BYTE 7/F
80 <8>LUT5
APC REF APC REF APC REF APC REF APC REF APC REF APC REF APC REF
88 <8>LUT5
APC REF APC REF APC REF APC REF APC REF APC REF APC REF APC REF
90 <8>LUT5
APC REF APC REF APC REF APC REF APC REF APC REF APC REF APC REF
98 <8>LUT5
APC REF APC REF APC REF APC REF APC REF APC REF APC REF APC REF
A0
<8>LUT5
APC REF APC REF APC REF APC REF RE SE RV ED RE SE RV ED RE SE RV ED RE SE RV ED
Access Code <0> <1> <2> <3> <4> <5> <6> <7> <8> <9> <10> <11>
Read Access All All All PW2 All N/A PW1 PW2 N/A PW2 All
Write Access
S ee each
b i t /b yt e
s ep ar at el y PW2 N/A Al l and
DS1863
Har dwar e
PW2 +
mode bit
All All PW1 PW2 PW2 N/A PW1
SPRINGER
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
24 ____________________________________________________________________
Lower Memory Register 00h to 01h: Temp Alarm Hi
FACTORY DEFAULT: 7FFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
00h
S2
6252423222120
01h
2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
bit7 bit0
Temperature measurements above this 2’s complement threshold will set its corresponding alarm bit. Measurements equal to or
below this threshold will clear its alarm bit.
Lower Memory Register 02h to 03h: Temp Alarm Lo
FACTORY DEFAULT: 8000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
02h
S2
6252423222120
03h
2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
bit7 bit0
Temperature measurements above this 2s complement threshold will set its corresponding alarm bit. Measurements equal to or
below this threshold will clear its alarm bit.
Lower Memory Register 04h to 05h: Temp Warn Hi
FACTORY DEFAULT: 7FFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
04h
S2
6252423222120
05h
2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
bit7 bit0
Temperature measurements above this 2s complement threshold will set its corresponding warning bit. Measurements equal to or
below this threshold will clear its warning bit.
Lower Memory Registers Description
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 25
Lower Memory Register 06h to 07h: Temp Warn Lo
FACTORY DEFAULT: 8000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
06h
S2
6252423222120
07h
2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
bit7 bit0
Temperature measurements below this 2s complement threshold will set its corresponding warning bit. Measurements above this
threshold will clear its warning bit.
Lower Memory Register 08h to 09h: VCC Alarm Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
08h
215 214 213 212 211 210 2928
09h
2726252423222120
bit7 bit0
Voltage measurements of the VCC input above this unsigned threshold will set its corresponding alarm bit. Measurements below
this threshold will clear its alarm bit.
Lower Memory Register 0Ah to 0Bh: VCC Alarm Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
0Ah
215 214 213 212 211 210 2928
0Bh
2726252423222120
bit7 bit0
Voltage measurements of the VCC below above this unsigned threshold will set its corresponding alarm bit. Measurements above
this threshold will clear its alarm bit.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
26 ____________________________________________________________________
Lower Memory Register 0Eh to 0Fh: VCC Warn Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
0Eh
215 214 213 212 211 210 2928
0Fh
2726252423222120
bit7 bit0
V ol tag e m easur em ents of the V
C C
b el ow ab ove thi s unsi g ned thr eshol d w i l l set i ts cor r esp ond i ng w ar ni ng b i t. M easur em ents ab ove
thi s thr eshol d w i l l cl ear i ts w ar ni ng b i t.
Lower Memory Register 10h to 11h: MON1 Alarm Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
10h
215 214 213 212 211 210 2928
11h
2726252423222120
bit7 bit0
Voltage measurements of the MON1 input above this unsigned threshold will set its corresponding alarm bit. Measurements below
this threshold will clear its alarm bit.
Lower Memory Register 0Ch to 0Dh: VCC Alarm Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
0Ch
215 214 213 212 211 210 2928
0Dh
2726252423222120
bit7 bit0
Voltage measurements of the VCC input above this unsigned threshold will set its corresponding warning bit. Measurements below
this threshold will clear its warning bit.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 27
Lower Memory Register 12h to 13h: MON1 Alarm Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
12h
215 214 213 212 211 210 2928
13h
2726252423222120
bit7 bit0
Voltage measurements of the MON1 input below this unsigned threshold will set its corresponding alarm bit. Measurements above
this threshold will clear its alarm bit.
Lower Memory Register 14h to 15h: MON1 Warn Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
14h
215 214 213 212 211 210 2928
15h
2726252423222120
bit7 bit0
Voltage measurements of the MON1 input above this unsigned threshold will set its corresponding warning bit. Measurements
below this threshold will clear its warning bit.
Lower Memory Register 16h to 17h: MON1 Warn Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
16h
215 214 213 212 211 210 2928
17h
2726252423222120
bit7 bit0
Voltage measurements of the MON1 input below this unsigned threshold will set its corresponding warning bit. Measurements
above this threshold will clear its warning bit.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
28 ____________________________________________________________________
Lower Memory Register 18h to 19h: MON2 Alarm Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
18h
215 214 213 212 211 210 2928
19h
2726252423222120
bit7 bit0
Voltage measurements of the MON2 input above this unsigned threshold will set its corresponding alarm bit. Measurements below
this threshold will clear its alarm bit.
Lower Memory Register 1Ah to 1Bh: MON2 Alarm Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
1Ah
215 214 213 212 211 210 2928
1Bh
2726252423222120
bit7 bit0
Voltage measurements of the MON2 input below this unsigned threshold will set its corresponding alarm bit. Measurements above
this threshold will clear its alarm bit.
Lower Memory Register 1Ch to 1Dh: MON2 Alarm Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
1Ch
215 214 213 212 211 210 2928
1Dh
2726252423222120
bit7 bit0
Voltage measurements of the MON2 input above this unsigned threshold will set its corresponding warning bit. Measurements
below this threshold will clear its warning bit.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 29
Lower Memory Register 1Eh to 1Fh: MON2 Warn Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
1Eh
215 214 213 212 211 210 2928
1Fh
2726252423222120
bit7 bit0
Voltage measurements of the MON2 input below this unsigned threshold will set its corresponding warning bit. Measurements
above this threshold will clear its warning bit.
Lower Memory Register 20h to 21h: MON3 Alarm Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
20h
215 214 213 212 211 210 2928
21h
2726252423222120
bit7 bit0
Voltage measurements of the MON3 input above this unsigned threshold will set its corresponding alarm bit. Measurements below
this threshold will clear its alarm bit.
Lower Memory Register 22h to 23h: MON3 Alarm Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
22h
215 214 213 212 211 210 2928
23h
2726252423222120
bit7 bit0
Voltage measurements of the MON3 input below this unsigned threshold will set its corresponding alarm bit. Measurements above
this threshold will clear its alarm bit.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
30 ____________________________________________________________________
Lower Memory Register 24h to 25h: MON3 Warn Hi
FACTORY DEFAULT: FFFFh
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
24h
215 214 213 212 211 210 2928
25h
2726252423222120
bit7 bit0
Voltage measurements of the MON3 input above this unsigned threshold will set its corresponding warning bit. Measurements
below this threshold will clear its warning bit.
Lower Memory Register 26h to 27h: MON3 Warn Lo
FACTORY DEFAULT: 0000h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
26h
215 214 213 212 211 210 2928
27h
2726252423222120
bit7 bit0
Voltage measurements of the MON3 input below this unsigned threshold will set its corresponding warning bit. Measurements
above this threshold will clear its warning bit.
Lower Memory Register 28h to 2Fh: Shadowed EEPROM
FACTORY DEFAULT: 00h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
28h-2Fh
SEE SEE SEE SEE SEE SEE SEE SEE
bit7 bit0
Shadowed EEPROM memory (see details in Memory Map section). PW2 level access controlled ROM data for end user.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 31
Lower Memory Register 30h to 5Fh: PW2 EE
FACTORY DEFAULT: 00h
READ ACCESS All
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (EE)
30h-5Fh
EE EE EE EE EE EE EE EE
bit7 bit0
Nonvolatile EEPROM memory. PW2 level access controlled ROM data for end user.
Lower Memory Register 60h to 61h: Temp Value
POWER-ON VALUE 0000h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE: Volatile
60h
S2
6252423222120
61h
2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-8
bit7 bit0
Signed 2s complement Direct-to-Temperature measurement.
Lower Memory, Register 62h–63h: VCC Value
Lower Memory, Register 64h–65h: MON1 Value
Lower Memory, Register 66h–67h: MON2 Value
Lower Memory, Register 68h–69h: MON3 Value
POWER-ON VALUE 0000h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE: Volatile
62h
215 214 213 212 211 210 2928
63h
2726252423222120
64h
215 214 213 212 211 210 2928
65h
2726252423222120
66h
215 214 213 212 211 210 2928
67h
2726252423222120
68h
215 214 213 212 211 210 2928
69h
2726252423222120
bit7 bit0
Unsigned voltage measurement.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
32 ____________________________________________________________________
Lower Memory, Register 6Ah to 6D: Reserved
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE
These registers are reserved. The value when read is 00h.
Lower Memory, Register 6Eh: Status
POWER-ON VALUE x000 0x0x b
READ ACCESS All
WRITE ACCESS See Below
MEMORY TYPE Volatile
Write
Access N/A All N/A All All N/A N/A N/A
6Eh
FETG
STATUS
SOFT
FETG
RESERVED
TX-F
RESET
SOFT
TX-D
TX-F
STATUS
RESERVED
RDYB
bit7 bit0
bit7
FETG STATUS: Reflects the active state of FETG.
0 = Bias and modulation outputs are enabled.
1 = The FETG output is asserted to disable the bias and modulation outputs.
bit6
SOFT FETG:
0 = (Default)
1 = Force the bias and modulation outputs to their off states and asserts the FETG output.
bit5 Reserved (Default = 0)
bit4
TX-F RESET:
0 = Does not affect the TX-F output (Default).
1 = Resets the latch for the TX-F output.
This bit is self clearing after the reset.
bit3
SOFT TX-D: This bit allows a software control that is identical to the TX-D pin. Please see section on
TX-D for further information. Its value is wired ORed with the logic value on TX-D pin.
0 = Internal TX-D signal is equal to external TX-D pin.
1 = Internal TX-D signal is high.
bit2
TX-F STATUS: Reflects the active state of TX-F.
0 = TX-F pin is not active.
1 = TX-F pin is active.
bit1
RESERVED (Default = 0)
bit0
RDYB: Ready Bar.
0 = VCC is above POA.
1 = VCC is below POA or too low to communicate over the I2C bus.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 33
Lower Memory, Register 6Fh: Update
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS All + DS1863 Hardware
MEMORY TYPE Volatile
6Fh TEMP RDY VCC RDY MON1 RDY MON2 RDY MON3 RDY RESERVED RESERVED RESERVED
bit7 bit0
Status of completed conversions. At Power-On, these bits are cleared and will be set as each conversion is completed. These bits
can be cleared so that a completion of a new conversion is verified.
bit7
TEMP RDY:
0 = Temperature conversion is not ready (Default).
1 = Temperature conversion is ready.
bit6
VCC RDY:
0 = VCC conversion is not ready (Default).
1 = VCC conversion is ready.
bit5
MON1 RDY:
0 = MON1 conversion is not ready (Default).
1 = MON1 conversion is ready.
bit4
MON2 RDY:
0 = MON2 conversion is not ready (Default).
1 = MON2 conversion is ready.
bit3
MON3 RDY:
0 = MON3 conversion is not ready (Default).
1 = MON3 conversion is ready.
bit2:0
RESERVED
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
34 ____________________________________________________________________
Lower Memory, Register 70h: Alarm3
POWER-ON VALUE 10h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE Volatile
70h
TEMP HI
TEMP LO VCC HI VCC LO MON1 HI MON1 LO MON2 HI MON2 LO
bit7 bit0
Alarm Status Bits
bit7
TEMP HI: High Alarm Status for Temperature measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit6
TEMP LO: Low Alarm Status for Temperature measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
bit5
VCC HI: High Alarm Status for VCC measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit4
VCC LO: Low Alarm Status for VCC measurement. This bit is set when the VCC supply is below the
POA trip point value. It will clear itself when a VCC measurement is completed and the value is above
the low threshold.
0 = Last measurement was equal to or above threshold setting.
1 = (Default) Last measurement was below threshold setting.
bit3
MON1 HI: High Alarm Status for MON1 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit2
MON1 LO: Low Alarm Status for MON1 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
bit1
MON2 HI: High Alarm Status for MON2 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit0
MON2 LO: Low Alarm Status for MON2 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 35
Lower Memory, Register 71h: Alarm2
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE Volatile
71h MON3 HI MON3 LO RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED
bit7 bit0
Alarm Status Bits
bit7
MON3 HI: High Alarm Status for MON3 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit6
MON3 LO: Low Alarm Status for MON3 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
bit5:0 RESERVED
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
36 ____________________________________________________________________
Lower Memory, Register 72h: Alarm1
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE Volatile
72h RESERVED RESERVED RESERVED RESERVED
BIAS HI
RESERVED
TX-P HI TX-P LO
bit7 bit0
Alarm Status Bits
bit7:4 RESERVED
bit3
BIAS HI: High Alarm Status Bias; Fast Comparison.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit2 RESERVED
bit1
TX-P HI: High Alarm Status TX-P; Fast Comparison.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit0
TX-P LO: Low Alarm Status TX-P; Fast Comparison.
0 = Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
Lower Memory, Register 73h: Alarm0
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE Volatile
73h RESERVED RESERVED RESERVED RESERVED BIAS MAX RESERVED RESERVED RESERVED
bit7 bit0
Alarm Status Bits
bit7:4 RESERVED
bit3 BIAS MAX: Maximum digital setting for IBIAS.
0 = (Default) The value of IBIAS is equal to or below MAX IBIAS setting.
1 = Requested value of IBIAS is greater than MAX IBIAS setting.
bit2:0 RESERVED
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 37
Lower Memory, Register 74h: Warn3
POWER-ON VALUE 10h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE Volatile
74h
TEMP HI
TEMP LO VCC HI VCC LO MON1 HI MON1 LO MON2 HI MON2 LO
bit7 bit0
Warning Status Bits
bit7 TEMP HI: High Warning Status for Temperature measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit6 TEMP LO: Low Warning Status for Temperature measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
bit5 VCC HI: High Warning Status for VCC measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit4
VCC LO: Low Warning Status for VCC measurement. This bit is set when the VCC supply is below the
POA trip point value. It will clear itself when a VCC measurement is completed and the value is above
the low threshold.
0 = Last measurement was equal to or above threshold setting.
1 = (Default) Last measurement was below threshold setting.
bit3 MON1 HI: High Warning Status for MON1 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit2 MON1 LO: Low Warning Status for MON1 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
bit1 MON2 HI: High Warning Status for MON2 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit0 MON2 LO: Low Warning Status for MON2 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
38 ____________________________________________________________________
Lower Memory, Register 75h: Warn2
POWER-ON VALUE 10h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE Volatile
75h MON3 HI MON3 LO RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED
bit7 bit0
Warning Status Bits
bit7 MON3 HI: High Warning Status for Mon3 measurement.
0 = (Default) Last measurement was equal to or below threshold setting.
1 = Last measurement was above threshold setting.
bit6 MON3 LO: Low Warning Status for Mon3 measurement.
0 = (Default) Last measurement was equal to or above threshold setting.
1 = Last measurement was below threshold setting.
bit5 RESERVED
Lower Memory, Register 76h to 7Ah: Reserved
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS N/A
MEMORY TYPE
These registers are reserved. The value when read is 00h.
Lower Memory, Register 7Bh to 7Eh: Password Entry (PWE)
FACTORY DEFAULT FFFF FFFFh
READ ACCESS N/A
WRITE ACCESS All
MEMORY TYPE Volatile
7Bh
231 230 229 228 227 226 225 224
7Ch
223 222 221 220 219 218 217 216
7Dh
215 214 213 212 211 210 2928
7Eh
2726252423222120
bit7 bit0
Password Entry. There are two passwords for the DS1863. Each password is 4 bytes long. The lower level password (PW1) will
have all the access of a normal user plus those made available with PW1. The higher level password (PW2) will have all of the
access of PW1 plus those made available with PW2. The values of the passwords reside in EE inside of PW2 memory. At Power up
all PWE bits are set to 1. All reads to this location are 0.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 39
Lower Memory Register 7Fh: Table Select (TBL SEL)
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS All
MEMORY TYPE Volatile
7Fh
2726252423222120
bit7 bit0
The upper memory tables (Table 01hTable 05h) of the DS1863 are accessible by writing the correct table value in this register.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
40 ____________________________________________________________________
Table 01h, Register F8h: Alarm3
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
F8h
TEMP HI
TEMP LO VCC HI VCC LO MON1 HI MON1 LO MON2 HI MON2 LO
bit7 bit0
Layout is identical to Alarm3 in Lower Memory Register 70h with two exceptions.
1. VCC Low alarm is not set at power-on.
2. These bits are latched. They are cleared by power-down or a write with PW1 access.
Table 01h, Register 80h to F7h: PW1 EEPROM
POWER-ON VALUE 00h
READ ACCESS PW1
WRITE ACCESS PW1
MEMORY TYPE Nonvolatile(EE)
80h-F7h
EE EE EE EE EE EE EE EE
bit7 bit0
EEPROM for PW1 level access.
Table 01h, Registers
Table 01h, Register F9h: Alarm2
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
F9h MON3 HI MON3 LO RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED
bit7 bit0
Layout is identical to Alarm2 in Lower Memory Register 71h with one exception.
1. These bits are latched. They are cleared by power-down or a write with PW1 access.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 41
Table 01h, Register FBh: Alarm0
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
72h
RESERVED RESERVED RESERVED RESERVED BIAS MAX RESERVED RESERVED RESERVED
bit7 bit0
Layout is identical to Alarm0 in Lower Memory Register 73h with one exception.
1. These bits are latched. They are cleared by power-down or a write with PW1 access
Table 01h, Register FAh: Alarm1
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
FAh
BIAS HI TX-P HI TX-P LO
RESERVED RESERVED RESERVED RESERVED RESERVED
bit7 bit0
Layout is identical to Alarm1 in Lower Memory Register 72h with one exception.
1. These bits are latched. They are cleared by power-down or a write with PW1 access.
Table 01h, Register FCh: Warn3
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
FCh
TEMP HI
TEMP LO VCC HI VCC LO MON1 HI MON1 LO MON2 HI MON2 LO
bit7 bit0
Layout is identical to Warn3 in Lower Memory Register 74h with two exceptions.
1. VCC Low Warning is not set at power-on.
2. These bits are latched. They are cleared by power-down or a write with PW1 access.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
42 ____________________________________________________________________
Table 01h, Register FDh: Warn2
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
FDh MON3 HI MON3 LO RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED
bit7 bit0
Layout is identical to Warn2 in Lower Memory Register 75h with one exception.
1. These bits are latched. They are cleared by power-down or a write with PW1 access.
Table 01h, Register FEh to FFh: Reserved
POWER-ON VALUE 00h
READ ACCESS All
WRITE ACCESS PW1
MEMORY TYPE Volatile
These registers are reserved.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 43
Table 02h, Register 80h: Mode
POWER-ON VALUE 0Fh
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Volatile
80h
SEEB
RESERVED RESERVED RESERVED
AEN MOD-EN APC-EN BIAS-EN
bit7 bit0
bit7
SEEB:
0 = Enables EEPROM writes to SEE bytes in Table 02h (Default).
1 = Disables EEPROM writes to SEE bytes during configuration, so that the configuration of the part is
not delayed by the EE cycle time. Once the values are known, write this bit to a 0 and write the SEE
locations again for data to be written to the EEPROM.
bit6:4
RESERVED
bit3
AEN:
0 = The temperature calculated index value (T Index) is write-able by the user and the updates of
calculated indexes are disabled. This allows the user to interactively test their modules by controlling
the indexing for the look-up tables. The recalled values from the LUTs will appear in the DAC registers
after the next completion of a temperature conversion (just like it would happen is auto mode). Both
DACs will update at the same time (just like auto mode).
1 = Enables auto control of the LUT (Default).
bit2
MOD-EN:
0 = MOD DAC is write-able by the user and the LUT recalls are disabled. This allows the user to
interactively test their modules by writing the DAC value for modulation. The output is updated with
the new value at the end of the write cycle. The I_C Stop condition is the end of the write cycle.
1 = Enables auto control of the LUT for modulation (Default).
bit1
APC-EN:
0 = APC DAC is write-able by the user and the LUT recalls are disabled. This allows the user to
interactively test their modules by writing the DAC value for APC reference. The output is updated
with the new value at the end of the write cycle. The I_C Stop condition is the end of the write cycle.
1 = Enables auto control of the LUT for APC reference (Default).
bit0
BIAS-EN:
0 = BIAS DAC is controlled by the user and the APC is open loop. The BIAS DAC value is written
to the MAN IBIAS Register. All values that are written to MAN IBIAS and are greater than the MAX
IBIAS register setting are not updated and will set the BIAS MAX alarm bit. The BIAS DAC
register will continue to reflect the value of the Bias DAC. This allows the user to interactively test their
modules by writing the DAC value for bias. The output is updated with the new value at the end of the
write cycle to the MAN IBIAS register. The I2C Stop condition is the end of the write cycle.
1 = Enables auto control for the APC feedback (Default).
Table 02h, Registers
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
44 ____________________________________________________________________
Table 02h, Register 81h: Tindex
POWER-ON VALUE 00h
READ ACCESS PW2
WRITE ACCESS PW2 and (AEN = 0)
MEMORY TYPE Volatile
81h
2726252423222120
bit7 bit0
Holds the calculated index based on the Temperature Measurement. This index is used for the address during Look-Up of Tables
04h and 05h.
For Table 04h, the exact address as the value of Tindex is used. For Table 05h the address used is calculated as follows
Table 02h, Register 82h: MOD DAC
POWER-ON VALUE 00h
READ ACCESS PW2
WRITE ACCESS PW2 and (MOD-EN = 0)
MEMORY TYPE Volatile
82h
2726252423222120
bit7 bit0
The digital value used for MOD and recalled from Table 04h at the adjusted memory address found in Tindex. The address used is
calculated as follows
This register is updated at the end of the Temperature conversion.
Tindex h h
+
80
280
Tindex Temperature C
Ch=
°
+
40
280
Tindex =+TEMP h40
2
Table 02h, Register 83h: APC DAC
POWER-ON VALUE 00h
READ ACCESS PW2
WRITE ACCESS PW2 and (APC-EN = 0)
MEMORY TYPE Volatile
83h
2726252423222120
bit7 bit0
The digital value used for APC reference and recalled from Table 05h at the memory address found in T Index. This register is
updated at the end of the Temperature conversion.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 45
Table 02h, Register 84h to 85h: BIAS DAC
FACTORY DEFAULT 00 00h
READ ACCESS PW2
WRITE ACCESS PW2 and (BIAS-EN = 0)
MEMORY TYPE Volatile
84h
002
12 211 210 292827
85h
2726252423222120
bit7 bit0
The digital value used for IBIAS.
Table 02h, Register 86h: Device ID
FACTORY DEFAULT 63h
READ ACCESS PW2
WRITE ACCESS N/A
MEMORY TYPE ROM
86h
01100011
bit7 bit0
Hard wired to show device ID.
Table 02h, Register 87h: Device VER
FACTORY DEFAULT Device Version
READ ACCESS PW2
WRITE ACCESS N/A
MEMORY TYPE ROM
87h
DEVICE VERSION
bit7 bit0
Hard wired connections to show Device Version.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
46 ____________________________________________________________________
Table 02h, Register 88h: Update Rate
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
Defines the update rate for comparison of APC control.
88h
0 0 0 0 SR(3:0)
bit7 bit0
bit7:4 0
bit3:0
SR(3:0) : 4-bit update rate for comparison of APC control.
SR3SR0
MINIMUM TIME
FROM BEN TO FIRST
SAMPLE (tFIRST)
±50ns
REPEATED SAMPLE
PERIOD FOLLOWING
FIRST SAMPLE (tREP)
0000b 350ns 800ns
0001b 550ns 1200ns
0010b 750ns 1600ns
0011b 950ns 2000ns
0100b 1350ns 2800ns
0101b 1550ns 3200ns
0110b 1750ns 3600ns
0111b 2150ns 4400ns
1000b 2950ns 6000ns
1001b* 3150ns 6400ns
*All codes greater than 1001b (1010b–111b) use the maximum
sample time of code 1001b.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 47
Table 02h, Register 8Ah: Startup Step
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
8Ah
212 211 210 2928272625
bit7 bit0
This value will define the maximum allowed step for the upper 8 bits of IBIAS output during start-up.
Table 02h, Register 89h: Config
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
89h
FE TG D IR
TX - F E N
RE S E RV E D
AS E L
RE S E RV E D RE S E RV E D RE S E RV E D RE S E RV E D
bit7 bit0
Configure the memory location and the polarity of the digital outputs.
bit7
FETG DIR: Chooses the direction or polarity of the FETG output for normal operation.
0 = Under normal operation, FETG will be pulled low. (Default)
1 = Under normal operation, FETG will be pulled high.
bit6
TX-F EN:
0 = The alarm bits will immediately reflect the status of the last comparison. (Default)
1 = The alarm bits are latched until cleared by a TX-D transition or Power-down. If VCC low alarm is
enabled for either FETG or TX-F then latching is disabled until after the first VCC measurement is
made above the VCC to set-point to allow for proper operation during slow power-on cycles.
bit5 RESERVED
bit4
ASEL: Address SELect.
0 = Device Address of A2h (Default).
1 = Device-Address is equal to the value found in byte device_address (Table 02h, 8Ch).
bit3:0 RESERVED
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
48 ____________________________________________________________________
Table 02h, Register 8Bh: MOD Ranging
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
8Bh RESERVED RESERVED RESERVED RESERVED RESERVED
MOD2MOD1MOD0
bit7 bit0
The lower nibble of this byte controls the Full-Scale range of the Modulation DAC
bit7:3
RESERVED (Default = 0)
bit2:0 MOD RANGING: 3-bit value to select FS output voltage for VMOD. Default 0006 and creates a
FS of 1.25V.
Table 02h, Register 8Ch: Device Address
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
8Ch
27262524232221X
bit7 bit0
X = Don't care.
This value becomes the Device address for the main memory when ASEL (Table 02h, 89h) bit is set.
MOD2 TO MOD0
% OF 1.25V FS VOLTAGE
000b 100 1.250
001b 80.05 1.001
010b 66.75 0.833
011b 50.13 0.627
100b 40.16 0.502
101b 33.5 0.419
110b 28.75 0.359
111b 25.18 0.315
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 49
Table 02h, Register 8Dh: Comp Ranging
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
8Dh RESERVED RESERVED RESERVED RESERVED RESERVED
APC2APC1APC0
bit7 bit0
This byte controls the Full-Scale range for the Quick-Trip monitoring of the APC reference as well as the closed loop monitoring of
APC.
bit7:3
RESERVED (Default = 0)
bit2:0 APC RANGING: 3-bit value to select the FS comparison voltage for BMD with the APC. Default is
000b and creates a FS voltage of 2.5V.
Table 02h, Register 8Eh: Right Shift1
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
8Eh RESERVED
MON1_2 MON1_1 MON1_0
RESERVED
MON2_2 MON2_1 MON2_0
bit7 bit0
Allows for right-shifting the final answer of MON1 and MON2 voltage measurements. This allows for scaling the measurements to
the smallest Full-scale voltage and then right-shifting the final result so the reading is weighted to the correct LSB.
APC2 TO APC0
% OF 2.5V FS VOLTAGE
000b 100 2.500
001b 80.07 2.002
010b 66.79 1.670
011b 50.18 1.255
100b 40.22 1.006
101b 33.57 0.839
110b 28.82 0.721
111b 25.26 0.632
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
50 ____________________________________________________________________
Table 02h, Register 8Fh: Right Shift0
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
8Fh RESERVED
MON3_2 MON3_1 MON3_0
RESERVED RESERVED RESERVED RESERVED
bit7 bit0
Allows for right-shifting the final answer of MON3 voltage measurements. This allows for scaling the measurements to the smallest
full-scale voltage and then right-shifting the final result so the reading is weighted to the correct LSB.
Table 02h, Register 90h to 91h: Reserved
FACTORY DEFAULT: 0000h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
These registers are reserved.
Table 02h, Register 92h to 93h: VCC Scale
FACTORY CALIBRATED
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
92h
215 214 213 212 211 210 2928
93h
2726252423222120
bit7 bit0
Controls the Scaling or Gain of the VCC measurements. The factory-calibrated value will produce a FS voltage of 6.5536V.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 51
Table 02h, Register 94h to 95h: MON1 Scale
Table 02h, Register 96h to 97h: MON2 Scale
Table 02h, Register 98h to 99h: MON3 Scale
FACTORY CALIBRATED
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
94h
215 214 213 212 211 210 2928
95h
2726252423222120
96h
215 214 213 212 211 210 2928
97h
2726252423222120
98h
215 214 213 212 211 210 2928
99h
2726252423222120
bit7 bit0
Controls the Scaling or Gain of the MON1, MON2, and MON3 measurements. The default hexadecimal value will correspond to
2.5V. The factory-calibrated value will produce a FS voltage of 2.5V.
Table 02h, Register 9Ah to A1h: Reserved
FACTORY DEFAULT 0000h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
These registers are reserved.
Table 02h, Register A2h to A3h: VCC Offset
FACTORY DEFAULT 0000h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
A2h
SS2
15 214 213 212 211 210
A3h
2928272625242322
bit7 bit0
Allows for offset control of VCC measurement if desired.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
52 ____________________________________________________________________
Table 02h, Register A4h to A5h: MON1 Offset
Table 02h, Register A6h to A7h: MON2 Offset
Table 02h, Register A8h to A9h: MON3 Offset
FACTORY DEFAULT 0000h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
A4h
SS2
15 214 213 212 211 210
A5h
2928272625242322
A6h
SS2
15 214 213 212 211 210
A7h
2928272625242322
A8h
SS2
15 214 213 212 211 210
A9h
2928272625242322
bit7 bit0
Allows for offset control of MON1, MON2, and MON3 measurement if desired.
Table 02h, Register AAh to ADh: Reserved
FACTORY DEFAULT 0000 0000h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
These registers are reserved.
Table 02h, Register AEh to AFh: Temp Offset
FACTORY CALIBRATED
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
AEh
S2
8272625242322
AFh
21202-1 2-2 2-3 2-4 2-5 2-6
bit7 bit0
Allows for offset control of Temp measurement if desired. The Final Result must be XORed with BB40h before writing to this
register. Factory calibration contains the desired value for a reading of the temperature in degrees celcius.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 53
Table 02h, Register B0h to B3h: PW1
FACTORY DEFAULT FFFF FFFFh
READ ACCESS N/A
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
B0h
231 230 229 228 227 226 225 224
B1h
223 222 221 220 219 218 217 216
B2h
215 214 213 212 211 210 2928
B3h
2726252423222120
bit7 bit0
The PWE value is compared against the value written to this location to enable PW1 access. At power-on, the PWE value is set to all
ones. Thus writing these bytes to all ones grants PW1 access on power-up without writing the password entry. All reads of this
register are 00h.
Table 02h, Register B4h to B7h: PW2
FACTORY DEFAULT FFFF FFFFh
READ ACCESS N/A
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
B4h
231 230 229 228 227 226 225 224
B5h
223 222 221 220 219 218 217 216
B6h
215 214 213 212 211 210 2928
B7h
2726252423222120
bit7 bit0
The PWE value is compared against the value written to this location to enable PW2 access. At power-on, the PWE value is set to all
ones. Thus writing these bytes to all ones grants PW2 access on power-up without writing the password entry. All reads of this
register are 00h.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
54 ____________________________________________________________________
Table 02h, Register B8h: FETG Enable1
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
B8h
TE M P E N V
C C
E N M ON 1 E N M ON 2 E N M ON 3 E N RE S E RV E D RE S E RV E D RE S E RV E D
bit7 bit0
Configures the maskable interrupt for the FETG pin.
bit7
TEMP EN: Enables/Disables active interrupts on the FETG pin due to temperature measurements
outside the threshold limits.
0 = Disable (Default)
1 = Enable
bit6
VCC EN: Enables/Disables active interrupts on the FETG pin due to VCC measurements outside the
threshold limits.
0 = Disable (Default)
1 = Enable
bit5
MON1 EN: Enables/Disables active interrupts on the FETG pin due to MON1 measurements
outside the threshold limits.
0 = Disable (Default)
1 = Enable
bit4
MON2 EN: Enables/Disables active interrupts on the FETG pin due to MON2 measurements
outside the threshold limits.
0 = Disable (Default)
1 = Enable
bit3
MON3 EN: Enables/Disables active interrupts on the FETG pin due to MON3 measurements
outside the threshold limits.
0 = Disable (Default)
1 = Enable
bit2:0
RESERVED (Default = 0)
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 55
Table 02h, Register B9h: FETG Enable0
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
B9h
TX P - H I E N TX P - LO E N BIAS - H I E N BIAS M AX E N RE S E RV E D RE S E RV E D RE S E RV E D RE S E RV E D
bit7 bit0
Configures the maskable interrupt for the FETG pin.
bit7
TX-P-HI EN: Enables/Disables active interrupts on the FETG pin due to Tx-P fast comparisons
above the threshold limit.
0 = Disable (Default)
1 = Enable.
bit6
TX-P-LO EN: Enables/Disables active interrupts on the FETG pin due to Tx-P fast comparisons
below the threshold limit.
0 = Disable (Default)
1 = Enable
bit5
BIAS-HI EN: Enables/Disables active interrupts on the FETG pin due to BIAS fast comparisons
above the threshold limit.
0 = Disable (Default)
1 = Enable
bit4
BIAS MAX EN: Enables/Disables active interrupts on the FETG pin due to BIAS fast comparisons
below the threshold limit.
0 = Disable (Default)
1 = Enable
bit3:0 RESERVED (Default = 0)
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
56 ____________________________________________________________________
Table 02h, Register BAh: TX-F Enable1
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
BAh
TE M P E N V
C C
E N M ON 1 E N M ON 2 E N M ON 3 E N RE S E RV E D RE S E RV E D RE S E RV E D
bit7 bit0
Configures the maskable interrupt for the TX-F pin.
bit7
TEMP EN: Enables/Disables active interrupts on the TX-F pin due to temperature measurements
outside the threshold limits.
0 = Disable (Default)
1 = Enable
bit6
VCC EN: Enables/Disables active interrupts on the TX-F pin due to VCC measurements outside the
threshold limits.
0 = Disable (Default)
1 = Enable
bit5
MON1 EN: Enables/Disables active interrupts on the TX-F pin due to MON1measurements outside
the threshold limits.
0 = Disable (Default)
1 = Enable
bit4
MON2 EN: Enables/Disables active interrupts on the TX-F pin due to MON2 measurements outside
the threshold limits.
0 = Disable (Default)
1 = Enable.
bit3
MON3 EN: Enables/Disables active interrupts on the TX-F pin due to MON3 measurements outside
the threshold limits.
0 = Disable (Default)
1 = Enable
bit2:0
RESERVED (Default = 0)
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 57
Table 02h, Register BBh: TX-F Enable0
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE Nonvolatile (SEE)
BBh TX P - H I E N TX P - LO E N BIAS - H I E N BIAS M AX E N RE S E RV E D RE S E RV E D RE S E RV E D
FE TG E N
bit7 bit0
Configures the maskable interrupt for the Tx-F pin.
bit7
TXP-HI EN: Enables/Disables active interrupts on the Tx-F pin due to Tx-P fast comparisons above
the threshold limit.
0 = Disable (Default)
1 = Enable.
bit6
TXP-LO EN: Enables/Disables active interrupts on the Tx-F pin due to Tx-P fast comparisons below
the threshold limit.
0 = Disable (Default)
1 = Enable
bit5
BIAS-HI EN: Enables/Disables active interrupts on the Tx-F pin due to BIAS fast comparisons
above the threshold limit.
0 = Disable (Default)
1 = Enable
bit4
BIAS MAX EN: Enables/Disables active interrupts on the Tx-F pin due to BIAS fast comparisons
above the threshold limit.
0 = Disable (Default)
1 = Enable
bit3:1
RESERVED (Default = 0)
bit0
FETG EN:
0 = Normal FETG operation (Default)
1 = Enables FETG to act as an input to Tx-F output.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
58 ____________________________________________________________________
Table 02h, Register BCh: HTXP
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
BCh
2726252423222120
bit7 bit0
Fast comparison DAC adjust for High TXP. This value is added to the APC_DAC value recalled from Table 04h. If the sum is greater
than 0xFF then 0xFF is used. Comparisons greater than APC_DAC plus this value, found on the BMD pin, will create a TX-P HI
alarm.
Table 02h, Register BDh: LTXP
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
BDh
2726252423222120
bit7 bit0
Fast comparison DAC adjust for Low TXP. This value is subtracted from the APC_DAC value recalled from Table 04h. If the
difference is less than 0x00 then 0x00 is used. Comparisons less than APC_DAC minus this value, found on the BMD pin, will
create a TX-PLO alarm.
Table 02h, Register BEh: HBIAS
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
BEh
2726252423222120
bit7 bit0
Fast comparison DAC setting for High BIAS.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 59
Table 02h, Register C0h to F7h: Empty
Table 02h, Register F8hF9h: MAN IBIAS
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2 and (BIAS-EN = 0)
MEMORY TYPE: Volatile
F8h RESERVED RESERVED
212 211 210 292827
F9h
2726252423222120
bit7 bit0
When BIAS-EN (Table 02h, 80h) is written to 0, writes to these bytes will control the lower portion of the IBIAS DAC [7:0].
Table 02h, Register FAh: MAN_CNTL
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2 and (BIAS-EN = 0)
MEMORY TYPE: Volatile
FAh RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED RESERVED MAN_CLK
bit7 bit0
When BIAS-EN bit (Table 02h, 80h) is written to zero, bit zero of this byte will control the updates of the MAN IBIAS value to the
Bias output. The Values of MAN IBIAS should be written with a separate write command. Setting bit zero to a 1 will clock the MAN
IBIAS value to the output DAC.
1. Write the MAN IBIAS value with a write command.
2. Set the MAN CLK bit to a 1 with a separate write command.
3. Clear the MAN CLK bit to a 0 with a separate write command.
Table 02h, Register BFh: MAX IBIAS
FACTORY DEFAULT: 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (SEE)
BFh
212 211 210 2928272625
bit7 bit0
Thi s val ue w i l l d efi ne the m axi m um D AC val ue al l ow ed for the up p er 8 b i ts of IBIAS outp ut d ur i ng al l op er ati ons. D ur i ng the i ni ti al step
and b i nar y sear ch, thi s val ue w i l l not cause an al ar m b ut w i l l sti l l cl am p the IBIAS D AC outp ut. After the star tup seq uence ( or nor m al
AP C op er ati ons) , i f the AP C l oop tr i es to cr eate an IBIAS val ue g r eater than thi s setti ng , IBIAS i s cl am p ed , and cr eates a BIAS M AX
al ar m . S etti ng s 00h thr oug h FE h ar e i ntend ed for nor m al AP C m od e of op er ati on. S etti ng FFh i s r eser ved for m anual IBIAS m od e.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
60 ____________________________________________________________________
Table 02h, Register FBh to FFh: Reserved
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE:
These registers are reserved.
Table 03h, Register 80h to FFh: PW2 EEPROM
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (EE)
80h-FFh
EE EE EE EE EE EE EE EE
bit7 bit0
PW2 general-purpose EEPROM.
Table 04h, Register 80h to C7h: Modulation LUT
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (EE)
80h-C7h
2726252423222120
bit7 bit0
The unsigned value for modulation DAC output.
The Modulation LUT is a set of registers assigned to hold the temperature profile for the Modulation DAC. The values in this table
combined with the MOD bits in the MOD Ranging register (Table 02h, Register 8Bh) determine the set point for the Modulation
Voltage. The temperature measurement is used to index the LUT (T INDEX, Table 02h, Register 81h) in 2°C increments from -40°C
to +102°C, starting at 80h in Table 04h. Register 80h defines the -40°C to -38°C MOD output, register 81h defines -38°C to -36°C
MOD output, and so on. Values recalled from this EEPROM memory table are written into the MOD DAC location which holds the
value until the next temperature conversion. The part can be placed into a manual mode (Mod_En bit, Table 02h, Register 80h),
where MOD DAC can be directly controlled for calibration. If the temperature compensation functionality is not required, then
program the entire Table 04h, to the desired modulation setting.
Table 03h, Register Descriptions
Table 04h, Register Descriptions
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
____________________________________________________________________ 61
Table 05h, Register 80h to C7h: APC Tracking Error LUT
FACTORY DEFAULT 00h
READ ACCESS PW2
WRITE ACCESS PW2
MEMORY TYPE: Nonvolatile (EE)
80h-A3h 2726252423222120
bit7 bit0
The Tracking Error LUT is set of registers assigned to hold the temperature profile for the APC reference DAC. The values in this
table combined with the APC bits in the Comp Ranging register (Table 02h, Register 8Dh) determine the set point for the APC loop.
The on board temperature measurement is used to index the LUT (T INDEX, Table 02h, Register 81h) in 4°C increments from -40°C
to +100°C, starting at register 80h in Table 05h. Register 80h defines the -40°C to -36°C APC reference value, register 81h defines
-36°C to -32°C APC reference value, and so on. Values recalled from this EEPROM memory table are written into the APC DAC
location, which holds the value until the next temperature conversion. The part can be placed into a manual mode (Apc_En bit,
Table 02h, Register 80h), where APC DAC can be directly controlled for calibration. If tracking error temperature compensation is
not required by the application, program the entire LUT to the APC set-point.
Table 05h, Register A3h to A7h: Reserved
FACTORY DEFAULT
READ ACCESS
WRITE ACCESS
MEMORY TYPE:
These registers are reserved.
Table 05h, Register Descriptions
PACKAGE TYPE PACKAGE CODE DOCUMENT NO.
16 TSSOP U16+1 21-0066
Package Information
For the latest package outline information and land patterns, go to www.maxim-ic.com/packages.
DS1863
Burst-Mode PON Controller
With Integrated Monitoring
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are
implied. Maxim reserves the right to change the circuitry and specifications without notice at any time.
62
____________________Maxim Integrated Products, 120 San Gabriel Drive, Sunnyvale, CA 94086 408-737-7600
© 2009 Maxim Integrated Products Maxim is a registered trademark of Maxim Integrated Products, Inc.
is a registered trademark of Dallas Semiconductor Corporation.
Revision History
REVISION
NUMBER
REVISION
DATE DESCRIPTION PAGES
CHANGED
0 10/06 Initial release.
Changed “triplexer” to “transceiver” in the General Description. 1
Added “Turn-Off Delay” and “Turn-On Delay” to the tOFF and tON PARAMETER specs
in the Control Loop and Quick-Trip Timing Characteristics table. 3
Corrected reference of “312-5mV” in Note 6 to312.5mV. 4
Changed IINIT to tON in Figure 1. 9
Corrected reference of “BIAS MAXto MAX IBIAS in the BIAS and MOD Output
During Initial Power-Up section. 9
Corrected reference of “MAX IBIAS” toBIAS MAXin the BIAS-EN (Table 02h) bit
description. 43
1 12/06
Corrected reference of “Factory Default to “Power-On Value in the register
descriptions for Tindex, MOD DAC, and APC DAC. 44
Replaced all instances of 5.5V with 3.9V. 1–5
28/09
Added the Analog Voltage Monitoring table. 5
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Maxim Integrated:
DS1863E+T&R DS1863E+