1
G
7
L
G7L
Power Relay
A High-capacity,
High-dielectric-strength Relay
Compatible with Momentary
Voltage Drops
No contact chattering for momentary voltage drops up to 50% of
rated voltage.
Wide-range AC-activated coil that handles 100 to 120 or 200 to
240 VAC at either 50 or 60 Hz.
Miniature size for maximum switching power, particularly for
inductive loads.
Flame-resistance materials (UL94V-0-qualifying) used for all
insulation material.
Quick-connect, screw, and PCB terminals, and DIN track
mounting available.
Conforms to UL, CSA, TUV and meets IEC950.
Safety design with contact gap of 3 mm.
List of E-bracket Mounting Models
RoHS Compliant
Mounting E-brackets DIN Track
Mounting
Adapter
Front-connecting
Socket
Terminal
Contact
form Model Test button
Quick-
connect
terminals
SPST-NO G7L-1A-T 
Note.
Accessories: E-bracket (R99-07), Adapter (P7LF-D),
Front-connecting socket (P7LF-06) and Cover
(P7LF-C) sold separately.
G7L-1A-TJ With test button 
DPST-NO G7L-2A-T 
G7L-2A-TJ With test button 
Screw
terminals
SPST-NO G7L-1A-B 
G7L-1A-BJ With test button 
DPST-NO G7L-2A-B 
G7L-2A-BJ With test button 
Note. Accessories: E-bracket, Adapter, Front-connecting socket
and Cover sold separately.
Application Examples
Compressors for air conditioners
and heater switching controllers.
Switching controllers for power tools
or motors.
Power controllers for water heaters.
Power controllers for dryers.
Lamp controls, motor drivers, and
power supply switching in copy
machines, facsimile machines, and
other office equipment.
Lighting controllers.
Power controllers for packers or
food processing equipment.
Magnetron control in microwaves.
Power controllers for Uninterruptible
Power Supply (UPS)
Model Number Legend
G7L-@@-@@@
—— ———
12 345
1. Number of Poles
1: 1 pole
2: 2 poles
2. Contact Form
A: @PST-NO
3. Terminal Shape
T: Quick connect
terminals (#250)
B: Screw terminals
P: PCB terminals
4. Mounting Construction
Blank: E-bracket
UB : Upper bracket
5. Special Functions
J : With test button
Model Configuration
Terminal Quick-connect
terminals Screw terminals PCB terminals
Classification Contact form
E-bracket
mounting
(E-bracket is
sold separately)
SPST-NO G7L-1A-T G7L-1A-B
DPST-NO G7L-2A-T G7L-2A-B
With test
button
SPST-NO G7L-1A-TJ G7L-1A-BJ
DPST-NO G7L-2A-TJ G7L-2A-BJ
Upper bracket
mounting
SPST-NO G7L-1A-TUB G7L-1A-BUB
DPST-NO G7L-2A-TUB G7L-2A-BUB
With test
button
SPST-NO G7L-1A-TUBJ G7L-1A-BUBJ
DPST-NO G7L-2A-TUBJ G7L-2A-BUBJ
PCB mounting SPST-NO −−G7L-1A-P
DPST-NO −−G7L-2A-P
2
G7L Power Relay
G
7
L
Ordering Information
E-bracket/Adapter/Socket Mounting
Quick-connect Terminal
Upper Bracket Mounting
Quick-connect Terminal
E-bracket/Adapter Mounting
Screw Terminal
Upper Bracket Mounting
Screw Terminal
PCB Mounting
DIN Track Mounting Accessories
Note. Order the models above in increments of the minimum quantity packaged.
E-bracket/Adapter/Socket Mounting (with test button)
Quick-connect Terminal
Upper Bracket Mounting (with test button)
Quick-connect Terminal
E-bracket/Adapter Mounting (with test button)
Screw Terminal
Upper Bracket Mounting (with test button)
Screw Terminal
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G7L-1A-T AC12
However, the notation of the coil voltage on the product case as well as
on the packing will be marked as @@ VDC.
Note 2. Refer to the precautions on PCB Relays provided in General
Information of the Relay Product Data Book, and "w -@-3" for coil
characteristics of AC operation.
E-bracket/Adaptor/Socket/Cover
Note. Order the models above in increments of the minimum quantity packaged.
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-T AC: 12, 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
2 poles G7L-2A-T AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-TUB AC: 12, 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
2 poles G7L-2A-TUB AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-B AC: 12, 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
2 poles G7L-2A-B AC: 12, 24, 100/120, 200/240
DC: 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-BUB AC: 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
2 poles G7L-2A-BUB AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-P AC: 100/120, 200/240
20 pcs./tray
DC: 12, 24, 48, 100
2 poles G7L-2A-P AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Applicable products Name Model Minimum
packing unit
Adaptor Surface
Connection Socket
DIN Track
PFP-100N
10 pcs.
PFP-50N
PFP-100N2
End plate PFP-M
Spacer PFP-S
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-TJ AC: 24, 100/120, 200/240
20 pcs./tray
DC: 12, 24, 48, 100
2 poles G7L-2A-TJ AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-TUBJ AC: 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48, 100
2 poles G7L-2A-TUBJ AC: 12, 24, 50, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-BJ AC: 12, 24, 100/120, 200/240
20 pcs./tray
DC: 12, 24
2 poles G7L-2A-BJ AC: 24, 100/120, 200/240
DC: 12, 24, 48, 100
Number
of poles Model Rated coil voltage Minimum
packing unit
1 pole G7L-1A-BUBJ AC: 24, 100/120, 200/240
20 pcs./tray
DC: 6, 12, 24, 48
2 poles G7L-2A-BUBJ AC: 24, 100/120, 200/240
DC: 6, 12, 24, 48, 100
Applicable Relay
models Name Model Minimum
packing unit
G7L-1A-T
G7L-1A-TJ
G7L-1A-B
G7L-1A-BJ
G7L-2A-T
G7L-2A-TJ
G7L-2A-B
G7L-2A-BJ
E-bracket R99-07 10 pcs.
Adapter P7LF-D 1 pcs.
G7L-1A-T
G7L-1A-TJ
G7L-2A-T
G7L-2A-TJ
Front-connecting
Socket P7LF-06 1 pcs.
G7L-1A-B
G7L-1A-BJ
G7L-1A-BUB
G7L-1A-BUBJ
G7L-2A-B
G7L-2A-BJ
G7L-2A-BUB
G7L-2A-BUBJ
Cover P7LF-C 1 pcs.
Rated coil voltage
3
G7L Power Relay
G
7
L
Engineering Data
G7L-1A-T (TJ) (TUB) (TUBJ)
G7L-1A-B (BJ) (BUB) (BUBJ)
Maximum Switching Power
G7L-2A-T (TJ) (TUB) (TUBJ)
G7L-2A-B (BJ) (BUB) (BUBJ)
Maximum Switching Power
G7L-1A-P
G7L-2A-P
Maximum Switching Power
Ambient Temperature vs. Operate
and Release Voltage
G7L-1A
VAC (60 Hz)
Endurance Endurance Endurance G7L-1A
VDC
Characteristics
Note. The values given above are initial values.
*1. Measurement conditions: 5 VDC, 1 A, voltage drop
method.
*2. Measurement conditions: Rated operating voltage applied,
not including contact bounce.
Ambient temperature: 23°C
*3. Measurement conditions: The insulation resistance was
measured with a 500-VDC megohmmeter at the same
locations as the dielectric strength was measured.
*4. JEC-212 (1981) Standard Impulse Wave Type (1.2×50
μ
s).
*5. Ambient temperature: 23°C
*6. This value was measured at a switching frequency of 60
operations/min.
Contact resistance *1 50 m
Ω
max.
Operate time *2 30 ms max.
Release time *3 30 ms max.
Max.
operating
frequency
Mechanical 1,800 operations/hr
Rated load 1,800 operations/hr
Insulation resistance *3 1,000 M
Ω
min
Dielectric
strength
Between coil and
contacts 4,000 VAC min., 50/60 Hz
for 1 min
Between contacts
of same polarity 2,000 VAC, 50/60 Hz for
1min
Between contacts
of different polarity
(DPST-NO model)
Impulse withstand voltage 10,000 V between coil and
contact *4
Vibration
resistance
Destruction 10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
Malfunction 10 to 55 to 10 Hz, 0.75 mm
single amplitude
(1.5 mm double amplitude)
Shock
resistance Destruction 1,000 m/s
2
Malfunction 100 m/s
2
Endurance
Mechanical 1,000,000 operations min.
(at 1,800 operations/hr)
Electrical *5 100,000 operations min.
(at 1,800 operations/hr
under rated load)
Failure rate (P level)
(reference value *6) 100 mA at 5 VDC
Weight
Approx. 90 g:
Quick-connect terminal
models
Approx. 100 g:
PCB terminal models
Approx. 120 g:
Screw terminal models
Ambient operating temperature -25°C to 60°C
(with no icing or
condensation)
Ambient operating humidity 5% to 85%
Ratings
Coil
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of
+15%/-20% for AC rated current and ±15% for DC coil resistance.
2. The inductances shown above are reference values.
3. Performance characteristic data are measured at a coil temperature of 23°C.
4. The maximum allowable coil voltage refers to the maximum value in a varying range of operating power
voltage, measured at ambient temperature 23°C.
5. The "to" (for example "100 to 120") represents the range of rated voltages.
Contacts
Note. When using B-series (screw) products, since the screw diameter of the contact terminal is M4, be careful
that the contact current should be 20 A or less according to JET standard (electrical appliance and material
control law of Japan).
Item Rated
current
(mA)
Coil
resistance
(
Ω
)
Coil inductance (H) Must operate
voltage Must release
voltage
Max.
permissible
voltage Power
consumption
(VA-W)
Rated voltage Armature
ON Armature
OFF
On the basis of rated voltage
12 VAC 142
75% max. 15% min. 110% Approx. 1.7
to 2.5
24 VAC 71
50 VAC 34
100 to 120 VAC 17.0 to 20.4 75 V max. 18 V min. 132 V
200 to 240 VAC 8.5 to 10.2 150 V max. 36 V min. 264 V
6 VDC 317 18.9 0.09 0.21
75% max. 15% min. 110% Approx. 1.9
12 VDC 158 75 0.37 0.88
24 VDC 79 303 1.42 3.54
48 VDC 40 1220 6.1 15.3
100 VDC 19 5260 21.3 60.0
Contact Form
load
Item
G7L-1A-T@
G7L-1A-B@G7L-2A-T@
G7L-2A-B@G7L-1A-P
G7L-2A-P
Resistive
load Inductive load
(cosφ = 0.4) Resistive
load
Inductive
load
(cosφ = 0.4)
Resistive
load
Inductive
load
(cosφ = 0.4)
Contact type Double break
Contact material Ag alloy
Rated load 30 A at 220 VAC 25 A at 220 VAC 25 A at 220 VAC 20 A at 220 VAC
Rated carry current 30 A 25 A 20 A
Max. switching
voltage 250 VAC
Max. switching
current 30 A 25 A 20 A
10 30 50 70 100 300 500 1,000
Switching voltage (V)
100
30
10
20
50
1
3
5
7
Switching current (A)
AC inductive load
(cosφ = 0.4)
AC resistive load
10 30 50 70 100 300 500 1,000
Ambient temperature (°C)
100
30
10
20
50
1
3
5
7
Switching current (A)
AC resistive load
AC inductive load
(cosφ = 0.4)
10 30 50 70 100 300 500
Switching voltage (V)
50
20
10
30
1
3
5
7
Switching current (A)
AC resistive load
AC inductive load
(cosφ = 0.4)
0 5 10 15 20 25 30
Switching current (A)
500
300
100
70
50
30
10
5
7
220 VAC resistive load
Endurance (x 10
4
operations)
220 VAC
inductive load
(cosφ = 0.4)
0 5 10 15 20 25 30
Switching current (A)
500
300
100
70
50
30
10
5
7
220 VAC resistive load
Endurance (x 10
4
operations)
220 VAC
inductive load
(cosφ = 0.4)
0 5 10 15 20 25 30
Switching current (A)
500
300
100
70
50
30
10
5
7
220 VAC resistive load
Endurance (x 104 operations)
220 VAC
inductive load
(cosφ = 0.4)
-40 -20 0 20 40 60 80
Ambient temperature (°C)
100
80
60
40
20
0
Operate and Release voltages (%)
Operate voltage
Release voltage
4
G7L Power Relay
G
7
L
Ambient Temperature vs.
Coil Temperature Rise
G7L-1A 120 VAC (50 Hz) G7L-1A VDC
Shock Malfunction
G7L-2A-T (TUB) 100 to 120 VAC
Momentary Voltage Drop Test
G7L-2A-T (TUB) 100 to 120 VAC
Test Circuit Wave resulted from test
Voltage distribution of wave e which
chattering does not occur.
Characteristic variation resulted from different mounting directions
G7L-2A-T (TUB) 100 to 120 VAC
Operate time Release time Operate voltage Release voltage
(Note.)The mounting direction A’ deteriorates switching performance.
Actual Load Endurance Test
G7L-2A 100 to 200 VAC
Operate and Release voltages
N = 5 Contact resistance
Operate and Release voltages
N = 5 Contact resistance
Load conditions Load conditions
•1 φ 220 VAC 1 φ 220 VAC
-40
Ambient temperature (°C)
80
60
40
20
0
0 A
15 A
30 A
N=5
Coil Temperature Rise (°C)
-20 0 20 40 60 80
80
60
40
20
0
-40
Ambient temperature (°C)
0 A
15 A
30 A
N=5
Coil Temperature Rise (
°C
)
-20 0 20 40 60 80
Y
XZ'
X'
Z
100
100
200
300
400
500
100
300
400
500 200
100
300
400
500 200
500
300
200
100 400
100
200
300
400
500
200
300
400
500
Y'
Unit: (m/s2)
N = 5
Test method: The value at which
malfunction occurred
was measured after
applying shock to the
test piece 3 times
each in 6 directions
along 3 axes.
Standard: 100m/s2
Shock direction
X
Y
Z
Z'
Y'
X'
Ch2
Ch1
Ch1
ON
OFF
(contact)
Ch2
(coil)
Rated
voltage
Without chattering
e
4020 60 80 100
On the basis of rated voltage (%)
8
6
4
2
0
Number of Relays
n=10
25
20
15
10
5
0
Time (ms)
A
To p
Bottom (Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Operate time
Time (ms)
35
30
25
20
15
0A
To p
Bottom (Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Release time
80
70
60
50
40
0
On the basis of rated voltage (%)
A
To p
Bottom(Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Operate voltage
50
40
30
20
10
0
On the basis of rated voltage (%)
A
To p
Bottom(Standard)
Mounting direction
(Note)
A' B B' C C'
N = 5
Release voltage
0.70.5 1 3 5 7 10 30 50
Switching operations (×104
operations)
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate voltage
Release voltage
N = 5
0.70.5 1 3 5 7 10 30 50
100
80
60
40
20
0
Contact resistance (mΩ)
N = 5
Switching operations (×10
4
operations)
0.070.05 0.1 0.3 0.5 1 3 5
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate
voltage
Release
voltage
N = 5
Switching operations (×10
4
operations)
0.070.05 0.1 0.3 0.5 1 3 5
50
40
30
20
10
0
Contact resistance (mΩ)
N = 5
Switching operations (×10
4
operations)
70 A cosφ = 0.4
20 A cosφ = 0.4
0.2s
1s 1s
Applied coil voltage: 100% of rated
voltage
54 A cosφ = 0.79
(Compressor Lock Test)
0.5s 10s
Applied coil voltage: 100% of rated
voltage
5
G7L Power Relay
G
7
L
Dimensions
E-bracket Mounting
Quick-connect Terminals
G7L-2A 100 to 200 VAC
Operate and Release voltages
N = 5 Contact resistance
Operate and Release voltages
N = 5 Contact resistance
Load conditions Load conditions
•1 φ 220 VAC 1 φ 220 VAC
0.70.5 1 3 5 10 30 50
Switching operations (×102 operations)
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate voltage
Release voltage
N = 5
0.70.5 1 3 5 10 30 50
50
40
30
20
10
0
Contact resistance (mΩ)
N = 5
Switching operations (×102 operations)
0.70.5 1 3 5 10 30 50
70
60
50
40
30
20
10
0
On the basis of rated voltage (%)
Operate voltage
Release voltage
N = 5
Switching operations (×10
2
operations)
0.70.5 1 3 5 10 30 50
50
40
30
20
10
0
Contact resistance (mΩ)
N = 5
Switching operations (×102 operations)
25 A cosφ = 1
2s 8s
Applied coil voltage: 75% of rated
voltage
70 A cosφ = 0.4
20 A cosφ = 0.4
0.2s
2s 8s
Applied coil voltage: 75% of rated
voltage
Note. E-brackets are sold separately.
Two, 4.5-dia. hole or
M4 tapped holes
11
52.5 max.
33.5 max.
53 max.
01
46
0.8
50.5 max.
6.35
11
52.5 max.
33.5 max.
53 max.
01
46
40±0.1
0.8
2
50.5 max.
6.35
11
52.5 max.
33.5 max.
53 max.
01
4268
0.8
2
50.5 max.
6.35
11
52.5 max.
33.5 max.
53 max.
01
4268
0.8
50.5 max.
6.35
Test
button
Test
button
G7L-1A-T Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-T
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-T
G7L-1A-TJ
(with Test Button)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-TJ
(with Test Button)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
6
G7L Power Relay
G
7
L
Adapter Mounting
Quick-connect Terminals
Front-connecting Socket Mounting
Quick-connect Terminals
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.
Test button
Test button
Two, M4 or 4.5-dia.
holes
55.5 max.
55.5 max.
63 max.
51.5 max.
66.5 max.
63 max.
51.5 max.
66.5 max.
PFP-@N
PFP-@N
G7L
G7L
P7LF-D
P7LF-D
40±0.1
01
4
5
5
5
2
2
5
6
01
4268
55.5 max.
55.5 max.
63 max.
51.5 max.
66.5 max.
63 max.
51.5 max.
66.5 max.
PFP-@N
PFP-@N
G7L
G7L
P7LF-D
P7LF-D
01
46
01
4268
G7L-1A-T Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-T
G7L-1A-TJ
(with Test Button)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-TJ
(with Test Button)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
Note 1. The Front-connecting Socket and DIN tracks are sold separately.
2. The Front-connecting Socket can be track-mounted or screw-mounted.
Two, M4 or 4.5-dia.
holes
51.5 max.
61.5 max.55.5 max.
65 max.
51.5 max.
61.5 max.55.5 max.
65 max.
PFP-@N2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-06
PFP-@N
G7L
P7LF-06 40±0.1
01
4
5
5
6
01
4268
G7L-1A-T Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-T
7
G7L Power Relay
G
7
L
Upper Bracket Mounting
Quick-connect Terminals
51.5 max.
61.5 max.
55.5 max.
65 max.
51.5 max.
61.5 max.
55.5 max.
65 max.
PFP-@N2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-06
PFP-@N
G7L
P7LF-06
01
4
5
5
2
2
6
01
4268
Test button
Test button
Two, M4 or 4.5-dia.
holes
40±0.1
G7L-1A-TJ
(with Test Button)
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-TJ
(with Test Button)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Two, 4.5-dia. hole or
M4 tapped holes
11
4.5
68.5 max.
33.5 max.
47 max.
01
46
01
4268
0.8
50.5 max.
6.35
60
11
2.5
4.5
68.5 max.
33.5 max.
47 max.
0.8
50.5 max.
6.35
60
11
2.5
4.5
68.5 max.
33.5 max.
47 max.
01
46
01
4268
0.8
2
2
50.5 max.
6.35
60
11
2.5
4.5
68.5 max.
33.5 max.
47 max.
0.8
50.5 max.
6.35
60
60±0.2
Test
button
Test
button
G7L-1A-TUB
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
G7L-2A-TUB
G7L-1A-TUBJ
(with Test Button)
G7L-2A-TUBJ
(with Test Button)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
8
G7L Power Relay
G
7
L
E-bracket Mounting
Screw Terminals
Adapter Mounting
Screw Terminals
Note. E-brackets are sold separately.
Two, 4.5-dia. hole or
M4 tapped holes
52.5 max.
34.5 max.
55 max.
50.5 max.
01
46
40±0.1
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
52.5 max.
34.5 max.
55 max.
50.5 max.
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
52.5 max.
34.5 max.
55 max.
50.5 max.
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
01
4268
01
46
01
4268
2
Test
button
52.5 max.
34.5 max.
55 max.
50.5 max.
2-M3.5 × 6
(coil side)
4-M4 × 8
(contact side)
2
Test
button
G7L-1A-B Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
G7L-2A-B
G7L-1A-BJ
(with Test Button)
G7L-2A-BJ
(with Test Button)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note 1. The DIN Track Mounting Adapter and DIN tracks are sold separately.
2. The DIN Track Mounting Adapter can be track-mounted or screw-mounted.
Two, M4 or 4.5-dia.
holes
51.5 max.
65.5 max.55.5 max.
69 max.
51.5 max.
65.5 max.55.5 max.
69 max.
PFP-@N2-M3.5 × 6 (coil side)
2-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-D
PFP-@N
G7L
P7LF-D 40±0.1
01
4
5
5
6
01
4268
G7L-1A-B Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
G7L-2A-B
Note. Refer to page 12 for the coil
internal connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil
internal connection diagram
(No coil polarity)
9
G7L Power Relay
G
7
L
Upper Bracket Mounting
Screw Terminals
Two, M4 or 4.5-dia.
holes
51.5 max.
65.5 max.55.5 max.
69 max.
51.5 max.
65.5 max.55.5 max.
69 max.
PFP-@N2-M3.5 × 6 (coil side)
2-M4 × 8 (contact side)
2-M3.5 × 6 (coil side)
4-M4 × 8 (contact side)
G7L
P7LF-D
PFP-@N
G7L
P7LF-D
40±0.1
01
4
5
2
2
5
6
01
4268
Test button
Test button
G7L-1A-BJ
(with Test Button) Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
Note. Refer to page 12 for the coil internal
connection diagram
G7L-2A-BJ
(with Test Button)
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Two, 4.5-dia. hole or
M4 tapped holes
2.5
4.5
68.5 max.
34.5 max.
49 max.
01
46
01
4268
50.5 max.
60
2.5
4.5
68.5 max.
34.5 max.
49 max.
50.5 max.
60
2.5
4.5
68.5 max.
34.5 max.
49 max.
01
46
01
4268
2
2
50.5 max.
60
2.5
4.5
68.5 max.
34.5 max.
49 max.
50.5 max.
60
60±0.2
Test
button
Test
button
2-M3.5 × 6
(coil side)
2-M3.5 × 6
(coil side)
2-M4 × 8
(contact side)
4-M4 × 8
(contact side)
2-M3.5 × 6
(coil side) 2-M4 × 8
(contact side)
2-M3.5 × 6
(coil side) 4-M4 × 8
(contact side)
G7L-1A-BUB
Terminal Arrangement/
Internal Connections
(Top View)
Mounting Holes
G7L-2A-BUB
G7L-1A-BUBJ
(with Test Button)
G7L-2A-BUBJ
(with Test Button)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
10
G7L Power Relay
G
7
L
PCB Mounting
PCB Terminals
36.8
14.4
3.2
1.2
4-1.2 × 3.2 square hole
17.7
6
2.8 0.8
52.5 max.
41 max.
35.5 max.
47 max.
01
46
(8.4)
(8.9)
G7L-1A-P Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
(8.4)
36.8
14.4
3.2
1.2
6-1.2 × 3.2 square hole
17.7
(8.9)
6
2.8 0.8
52.5 max.
41 max.
35.5 max.
47 max.
01
24 86
G7L-2A-P Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
Note. Refer to page 12 for the coil internal
connection diagram
(No coil polarity)
Two, 4.5-dia. hole
26 24
24
17.8
40
46 10
4.4
3
19.7
30
50
55
7
40
Two, M4 or 4.5-dia.
holes
E-bracket
R99-07 (E KANAGU)
FOR G7L
Mounting Holes
14.5 5
Two, M4 or 4.5-dia.
holes
55.5 max. 35.2 max.
51.5 max.
40±0.1
40±0.1
Adapter
P7LF-D Mounting Holes
40±0.1
8±0.05
9.2±0.05
55.5 max.
46 max.
51.5 max.
25 5
Two, M4 or 4.5-dia.
holes
40±0.1
2-M3.5 × 6 (coil side)
4-M4 × 8
(contact side)
Front-connecting
Socket
P7LF-06
Mounting Holes
34.5 max.
50.5 max.
6 max.
1
Cover
P7LF-C
Put the P7LF-C cover onto the terminals in order to protect the
user from electric shock.
11
G7L Power Relay
G
7
L
A variety of Safety Standard approved products for standard models.
UL Recognized (File No. E41643)
CSA certified (File No. LR31928)
Reference
UL Approved Type ....................................................
UL508 Industrial Control Devices
UL1950 Information processing equipment
(Including office equipment)
CSA Approved Type ..................................................
CSA C22.2 No.1, 14
Industrial Control Devices
CSA C22.2 No.950 Information processing equipment
(Including office equipment)
TÜV EN/IEC Standard Approved Type......................
EN61810-1 Relay
EN/IEC, TÜV Certified (Certificate No. R50059083)
Approved Standards
Model Coil ratings Contact ratings Number of test
operations
G7L-1A-T
@
G7L-1A-B
@
G7L-1A-P
G7L-2A-T
@
G7L-2A-B
@
G7L-2A-P
12 to 240 VAC
6 to 220 VDC
30 A, 277 VAC (RES) 40°C 100,000
1.5 kW, 120 VAC (T) 40°C 6,000
1.5 HP, 120 VAC 40°C 1,000
3 HP 277 VAC 40°C 100,000
20 FLA/120 LRA, 120 VAC 40°C 30,000
17 FLA/102 LRA, 277 VAC 40°C
TV-10, 120 VAC 40°C 25,000
Model Coil ratings Contact ratings Number of test
operations
G7L-1A-P 12 to 240 VAC
6 to 220 VDC
2.4 kW, 120 VAC (T) 40°C 6,000
1.5 HP, 120 VAC (T) 40°C 1,000
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C 100,000
TV-10, 120 VAC 40°C 25,000
G7L-1A-T
@
G7L-1A-B
@
G7L-2A-T
@
G7L-2A-B
@
G7L-2A-P
12 to 240 VAC
6 to 220 VDC
30 A, 277 VAC (RES) 40°C 100,000
2.4 kW, 120 VAC (T) 40°C 6,000
1.5 HP, 120 VAC 40°C 1,000
3 HP 277 VAC 40°C
20.5 FLA/105 LRA, 120 VAC 85°C 100,000
TV-10, 120 VAC 40°C 25,000
Model Coil ratings Contact ratings
Approved
switching
operations
G7L-1A-B
@
6, 12, 24, 48,
100, 110, 200,
220 VDC
12, 24, 50,
100 to 120,
200 to 240
VAC
SPST-NO (1a)
50,000
30 A, 250 VAC ~ (cos
φ
= 1) 60°C
25 A, 250 VAC ~ (cos
φ
= 0.4) 60°C
30 A, 120 VAC ~ (cos
φ
= 0.4) 60°C
G7L-2A-B
@
DPST-NO (2a)
50,000
25 A, 277 VAC ~ (cos
φ
= 1) 60°C
25 A, 277 VAC ~ (cos
φ
= 0.4) 60°C
G7L-1A-T
@
SPST-NO (1a)
50,000
25 A, 240 VAC ~ (cos
φ
= 1) 60°C
25 A, 240 VAC ~ (cos
φ
= 0.4) 60°C
25 A, 277 VAC ~ (cos
φ
= 1) 60°C
25 A, 277 VAC ~ (cos
φ
= 0.4) 60°C
G7L-2A-T
@
DPST-NO (2a)
50,000
25 A, 240 VAC ~ (cos
φ
= 1) 60°C
25 A, 240 VAC ~ (cos
φ
= 0.4) 60°C
25 A, 277 VAC ~ (cos
φ
= 1) 60°C
25 A, 277 VAC ~ (cos
φ
= 0.4) 60°C
G7L-1A-P
SPST-NO (1a)
50,000
20 A, 240 VAC ~ (cos
φ
= 1) 60°C
20 A, 240 VAC ~ (cos
φ
= 0.4) 60°C
25 A, 277 VAC ~ (cos
φ
= 1) 60°C
25 A, 277 VAC ~ (cos
φ
= 0.4) 60°C
G7L-2A-P
DPST-NO (2a)
50,000
20 A, 240 VAC ~ (cos
φ
= 1) 60°C
20 A, 240 VAC ~ (cos
φ
= 0.4) 60°C
25 A, 277 VAC ~ (cos
φ
= 1) 60°C
25 A, 277 VAC ~ (cos
φ
= 0.4) 60°C
12
G7L Power Relay
G
7
L
Precautions
Please refer to “PCB Relays Common Precautions” for general precautions.
Installation
Although there are not specific limits
on the installation site, it should be as
dry and dust-free as possible.
Using in an atmosphere of high
temperature, high humidity and
corrosive gas may deteriorate its
performance characteristic caused by
condensation or corrosive products,
resulting in failure or burn damage of
the Relay.
PCB Terminal-equipped Relays weigh
approximately 100 g.
Be sure that the PCB is strong enough
to support them. We recommend
dual-side through-hole PCBs to
reduce solder cracking from heat
stress.
Relays with test buttons must be
mounted facing down.
Be careful not to touch the test button
accidentally. Doing so may turn ON
the contact.
Be sure to use the test button for test
purposes only (with test-button
models). The test button is used for
Relay circuit tests, such as circuit
continuity tests. Do not attempt to
switch the load with the test button.
Micro Loads
The G7L is used for switching power
loads, such as motor, transformer,
solenoid, lamp, and heater loads. Do
not use the G7L for switching micro
loads, such as signals.
Soldering PCB Terminals
Do not perform automatic soldering
but solder manually.
Solder with the following conditions:
Soldering iron temperature (max.)
380°C, Soldering time within 10
seconds.
Do not wash down the entire Relay
because it does not have an airtight
construction.
Correct Use
Connecting
Refer to the following table when
connecting a wire with a crimpstyle
terminal to the G7L.
Allow suitable slack on leads when
wiring, and do not apply excessive
force to the terminals.
Tightening torque
Coil: 0.78 to 1.18 N . m
Contact: 0.98 to 1.37 N . m
Screw terminals Front-connecting
Socket
Coil
Contact
8
5
M3.5
5.8
8
5.3
M3.5
6.5
9.2
5.5
M4
6.5
9.2
5.5
M4
7
When connecting with screws, if the
screws are not sufficiently tightened,
the lead wire can become detached
and may lead to abnormal heating or
fire caused by faulty contact.
Mounting Torque
0.98N . m
Tighten with two M4 screws when
mounting.
(Top bracket type)
Do not apply excessive force when
mounting or dismounting the Faston
receptacle.Insert and remove
terminals carefully one at a time. Do
not insert terminals at an angle, or
insert/remove multiple terminals at the
same time.
Do not connect to the terminals by
soldering
Refer to the following table for
recommendations of connectors
made by OMRON.
Note. The current should be 25 A when using receptacle terminals.
Type Receptacle terminals Housing
#250 terminals
(width: 6.35 mm)
XT3W-S441-12
XT3W-S442-12
XT3W-S443-12
XT3B-1S white
Reference Data
The ratio of rated voltage between 100
to 120 VAC are values measured on
the basis of 100 VAC.
Operating Coil
(Coil internal connections diagram)
DC Coil
•AC Coil
If a transistor drives the G7L check the
leakage current, and connect a
bleeder resistor if necessary.
The AC coil is provided with a built-in
full-wave rectifier. If a triac, such as an
SSR, drives the G7L, the G7L may not
release. Be sure to perform a trial
operation with the G7L and the triac
before applying them to actual use.
01
01
DIN Track Mounting Adapter and
Front-connecting Socket
(DIN Track Mounting)
The DIN Track Mounting Adapter and
Front-connecting Socket can be
mounted on the G7L with just one
hand and dismounted with ease by
using a screwdriver.
To support the G7L mounted on a DIN
Track Mounting Adapter or
Front-connecting Socket, use the
PFP-M End Plate. Put the End Plate
onto the DIN Track Mounting Adapter
or Front-connecting Socket so that the
surface mark of the End Plate faces
upwards. Then tighten the screw of
the End Plate securely with a
screwdriver.
(Screw Mounting)
Screw-mount the DIN Track Mounting
Adapter or Front-connecting Socket
securely after opening screw mounting
holes on them.
When cutting or opening holes on the
panel after the Front-connecting
Socket is mounted, take proper
measures so that the cutting chips will
not fall onto the Relay terminals. When
cutting or opening holes on the upper
part of the panel, mask the
Front-connecting Socket properly with
a cover.
13
G7L Power Relay
G
7
L
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Cat. No. J055-E1-15
0519(0207)(O)
Note: Do not use this document to operate the Unit.
OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb