Part Number: 2413F CAT6+ Horizontal, 4pr, F/UTP, LS-PVC Jkt, CMP Product Description CAT6+ (350MHz), 4-Pair, F/UTP-foil shielded, Plenum-CMP, Premise Horizontal cable, 23 AWG solid bare copper conductors, FEP/PO insulation, patented X-spline, overall Beldfoil(R) shield, Flamarrest(R) jacket Technical Specifications Product Overview Environmental Space: Plenum Suitable Applications: Networking Horizontal Cable, HDBaseT, 1000Base-T (Gigabit Ethernet), 100Base-T (Fast Ethernet), 10Base-T (Ethernet), 100BaseVG, ANYLAN, 155ATM, 622ATM, ANSI.X3.263 FDDI TP-PMD, NTSC/PAL Component or Composite Video, AES/EBU, Digital Video, RS-422, Noisy Environments, 250 MHz Category 6 Physical Characteristics (Overall) Conductor AWG Stranding 23 Solid Material No. of Pairs BC - Bare Copper 4 Conductor Count: 8 Total Number of Pairs: 4 Conductor Size: 23 AWG Insulation Material FEP - Fluorinated Ethylene Propylene Bonded-Pair: N/A Color Chart Number Color 1 White/Blue Stripe & Blue 2 White/Orange Stripe & Orange 3 White/Green Stripe & Green 4 White/Brown Stripe & Brown Outer Shield Material Type Material Material Trade Name Coverage [%] Drainwire Material Tape Aluminum/Polyester Beldfoil(R) 100 % Drainwire AWG Drainwire Construction n x D TC - Tinned Copper 24 Solid Outer Jacket Material Material Material Trade Name Nominal Diameter Ripcord Separator Material LS PVC - Low Smoke Polyvinyl Chloride Flamarrest(R) Construction and Dimensions Cabling Filler Patented Central X-Spline Electrical Characteristics 0.310 in No Polyester Tape Conductor DCR Max. Conductor DCR Max. DCR Unbalance 93.8 Ohm/km 5% Capacitance Max. Capacitance Unbalance Nom.Mutual Capacitance 330 pF/100m 14 pF/ft Delay Frequency [MHz] 100 MHz Max. Delay Max. Delay Skew Nominal Velocity of Propagation (VP) [%] 537.6 ns/100m 45 ns/100m 72 % High Freq Frequency [MHz] Min. NEXT [dB] Max. Insertion Loss (Attenuation) Min. PSNEXT [dB] Min. ACR [dB] Min. PSACR [dB] Min. ACRF (ELFEXT) [dB] Min. PSACRF (PSELFEXT) [dB] Min. RL (Return Loss) [dB] Max./Min. Input Impedance (unFitted) Max./Min. Fitted Impedance Min. TCL [dB] Min. ELTCTL [dB] 0.772 MHz 1.8 dB/100m 77.0 dB 77.0 dB 75.2 dB 76.2 dB 73.0 dB 70.0 dB 19.4 dB 100 +/- 15 100 15 Ohm 40.0 dB 37.2 dB 1 MHz 2.0 dB/100m 75.3 dB 75.3 dB 73.3 dB 74.3 dB 70.8 dB 67.8 dB 20.0 dB 100 +/- 15 100 15 Ohm 40.0 dB 35.0 dB 4 MHz 3.7 dB/100m 66.3 dB 66.3 dB 62.6 dB 63.6 dB 58.8 dB 55.8 dB 23.0 dB 100 +/- 15 100 15 Ohm 40.0 dB 23.0 dB 8 MHz 5.2 dB/100m 61.8 dB 61.8 dB 56.6 dB 57.6 dB 52.7 dB 49.7 dB 24.5 dB 100 +/- 15 100 15 Ohm 40.0 dB 16.9 dB 10 MHz 5.8 dB/100m 60.3 dB 60.3 dB 54.5 dB 55.5 dB 50.8 dB 47.8 dB 25.0 dB 100 +/- 15 100 15 Ohm 40.0 dB 15.0 dB 16 MHz 7.4 dB/100m 57.2 dB 57.2 dB 49.9 dB 50.9 dB 46.7 dB 43.7 dB 25.0 dB 100 +/- 15 100 15 Ohm 38.0 dB 10.9 dB 20 MHz 8.3 dB/100m 55.8 dB 55.8 dB 47.5 dB 48.5 dB 44.8 dB 41.8 dB 25.0 dB 100 +/- 15 100 15 Ohm 37.0 dB 9.0 dB 25 MHz 9.3 dB/100m 54.3 dB 54.3 dB 45.1 dB 46.1 dB 42.8 dB 39.8 dB 24.3 dB 100 +/- 15 100 15 Ohm 36.0 dB 7.0 dB 31.25 MHz 10.4 dB/100m 52.9 dB 52.9 dB 42.5 dB 43.5 dB 40.9 dB 37.9 dB 23.6 dB 100 +/- 15 100 15 Ohm 35.1 dB 5.1 dB 62.5 MHz 15.0 dB/100m 48.4 dB 48.4 dB 33.4 dB 34.4 dB 34.9 dB 31.9 dB 21.5 dB 100 +/- 15 100 15 Ohm 32.0 dB 100 MHz 19.3 dB/100m 45.3 dB 45.3 dB 26.0 dB 27.0 dB 30.8 dB 27.8 dB 20.1 dB 100 +/- 15 100 15 Ohm 30.0 dB 155 MHz 24.6 dB/100m 42.4 dB 42.4 dB 17.9 dB 18.9 dB 27.0 dB 24.0 dB 19.5 dB 100 +/- 22 100 15 Ohm 28.1 dB 200 MHz 28.3 dB/100m 40.8 dB 40.8 dB 12.5 dB 13.5 dB 24.8 dB 21.8 dB 18.7 dB 100 +/- 22 100 15 Ohm 27.0 dB 250 MHz 32.1 dB/100m 39.3 dB 39.3 dB 7.2 dB 8.2 dB 22.8 dB 19.8 dB 18.0 dB 100 +/- 32 100 15 Ohm 26.0 dB 300 MHz 35.6 dB/100m 38.1 dB 36.1 dB 2.5 dB 1.5 dB 21.3 dB 18.3 dB 17.5 dB 100 +/- 32 100 15 Ohm 25.2 dB 350 MHz 38.9 dB/100m 37.1 dB 35.1 dB 19.9 dB 16.9 dB 17.0 dB 100 +/- 32 100 15 Ohm 24.6 dB 400 MHz 42.0 dB/100m 36.3 dB 34.3 dB 18.8 dB 15.8 dB 16.6 dB 100 +/- 32 100 15 Ohm 24.0 dB 450 MHz 45.0 dB/100m 35.5 dB 33.5 dB 17.7 dB 14.7 dB 16.2 dB 100 +/- 32 100 15 Ohm 23.5 dB 500 MHz 47.9 dB/100m 34.8 dB 32.8 dB 16.8 dB 13.8 dB 15.9 dB 100 +/- 32 23.0 dB 550 MHz 50.6 dB/100m 34.2 dB 32.2 dB 16.0 dB 13.0 dB 15.6 dB 100 +/- 32 22.6 dB Voltage UL Voltage Rating 300 V RMS Temperature Range Installation Temp Range: 0C To +50C UL Temp Rating: 75C Storage Temp Range: -20C To +75C Operating Temp Range: -20C To +75C Mechanical Characteristics Bulk Cable Weight: 44 lbs/1000ft Max Recommended Pulling Tension: 25 lbs Min Bend Radius During Installation: 2.25 in Min Bend Radius/Minor Axis: 1.0 in Standards NEC/(UL) Specification: CMP CEC/C(UL) Specification: CMP ISO/IEC Compliance: 11801 ed 2.2 (2011) Class E CPR Euroclass: Eca Data Category: Category 6 ANSI Compliance: S-116-732-2013 Category 6, ANSI/NEMA WC-66 Category 6 Telecommunications Standards: ANSI/TIA-568-C.2 Category 6 IEEE Specification: IEEE 802.3bt Type 1, Type 2, Type 3, Type 4 Third Party Performance Verification: Category 6 Applicable Environmental and Other Programs EU Directive 2000/53/EC (ELV): Yes EU Directive 2002/96/EC (WEEE): Yes EU Directive 2003/11/EC (BFR): Yes EU Directive 2003/96/EC (BFR): Yes EU Directive 2011/65/EU (ROHS II): Yes EU Directive 2012/19/EU (WEEE): Yes EU Directive 2015/863/EU: Yes EU Directive Compliance: Yes EU CE Mark: Yes EU REACH SVHC Compliance (yyyy-mm-dd): 2017-07-10 EU RoHS Compliance Date (yyyy-mm-dd): 2004-01-01 CA Prop 65 (CJ for Wire & Cable): Yes MII Order #39 (China RoHS): Yes Suitability Suitability - Aerial: No Suitability - Burial: No Suitability - Hazardous Locations: No Suitability - Indoor: Yes Suitability - Non-Halogenated: No Suitability - Oil Resistance: No Suitability - Outdoor: No Suitability - Sunlight Resistance: No Flammability, LS0H, Toxicity Testing C(UL) Flammability: FT6 UL Flammability: NFPA 262 Plenum (UL 910) CSA Flammability: FT6 ISO/IEC Flammability: IEC 60332-1-2 UL voltage rating: 300 V RMS Plenum/Non-Plenum Plenum (Y/N): Yes Part Number Non-Plenum Number: 2412F Variants Item # 2413F 0101000 Color Black UPC Length 612825131601 1,000 ft 2413F D151000 Blue 612825131526 1,000 ft 2413F D15A500 Blue 612825131519 500 ft 2413F 0081000 Gray 612825131571 1,000 ft 2413F 0051000 Green 612825131564 1,000 ft 2413F 0031000 Orange 612825131540 1,000 ft 2413F 0021000 Red 612825131533 1,000 ft 2413F 0091000 White 612825131595 1,000 ft 2413F 009A500 White 612825131588 500 ft 2413F 0041000 Yellow 612825131557 1,000 ft Patent: https://www.belden.com/resources/patents Product Notes Notes: Values above 300 MHz are for Engineering Information Only. Shield is Bonded to Jacket Inner Wall for Electrical Stability. Print Includes Descending Footage Markings from Max. Put-Up Length to 0. History Update and Revision: Revision Number: 0.356 Revision Date: 07-11-2019 (c) 2019 Belden, Inc All Rights Reserved. Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without notice, and the listing of such information and specifications does not ensure product availability. Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract, negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein. All sales of Belden products are subject to Belden's standard terms and conditions of sale. Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and regulations based on their individual usage of the product.