Standard Heavy Duty
Limit Switches FD/FP/FL
Heavy duty limit switches with snap-action contacts and
positive break according to BS/EN60947-5-1.
■Bifurcated contacts for low resistance and high reliability
– suitable for switching low-level electronic currents
■Double-break contacts with electrically separate NO and
NC circuits in conformity with VDE 0660 part 206
■10A 500VAC/600VDC rated
■Lever types can be user-set to switch by clockwise
movement only, anti-clockwise only or both
■Turret head position rotatable in 90˚ increments
■Centre-position indicator arrow – lever actuators
■Wide range of actuators
■Single and triple cable entry models
■Removable contact block for ease of wiring
■Metal or plastic housing options
■IP66 according to BS EN60947-1
■FD and FP dimensions in accordance with EN50041
■Approvals: UL, CSA
Options and ordering codes
Specifications
Contact ratings Terminal connections
FD
FP
FL
5
6
7
9
10
11
20
21
22
2
–
385
L313
L353
L354
FD 5 01
Heavy duty metal housing
Heavy duty plastic housing
Triple entry metal housing
Snap-action contacts, 1NO + 1NC
Slow-action, break before make 1NO + 1NC
Slow-action, make before break 1NO + 1NC
Slow-action contacts, 2NC
Slow-action contacts, 2NO
Snap-action contacts, 2NC
Slow-action contacts, break before make 2NC + 1NO
Slow-action contacts, break before make 3NC
Slow-action contacts, break before make 1NC + 2NO
Snap-action contacts, 2NO + 2NC
Standard actuators – options overleaf
38 Lift-style turret with 75˚ total travel
Lift-style turret with 90˚ total travel
Specify lever type for lift-style switch:
Fixed position roller
Single adjustment roller
Dual adjustment roller
Please note: Positive break
applies to the NC contacts of
types 5, 6, 7, 9, 11, 20, 21
and 22 only.
Rated thermal current Ith 10A
Rated working voltage 500VAC/600VDC
Maximum operating frequency 6000/hour
Mechanical life >20 million operations
Contact form 1NO + 1NC
Initial contact resistance <25 mOhms
Contact gap >2.5mm (2 x 1.25mm conforming to VDE 0660 part 206)
Contact material silver
Dielectric strength 2000VAC, 50/60Hz for 1 minute between open contacts
2000VAC, 50/60Hz for 1 minute between current-carrying parts and ground
Protection rating IP66
Ambient operating temperature –25 to +80 deg. C
Ambient humidity 95% R.H.
Maximum wire size 2 x 1.5mm2flexible, 2 x 2.5mm2solid
Housing material FD/FL: die-cast metal alloy, FP: self-extinguishing, glass-reinforced, thermoplastic resin
Conduit entry PG 13.5
BS/EN 60947-5-1
AC15 – Control of AC electromagnetic 230VAC 6A
loads>72VA sealed – replaces AC11 400VAC 4A
500VAC 1A
DC13 – Control of DC electromagnetic 24VDC 6A
loads where the time taken to reach 125VDC 1.1A
95% of the rated current is equal to 250VDC 0.4A
6 times the power of the load (where P<50W) – replaces DC11
Terminal screws: M3.5 with rising cable clamps.
Standard contacts (type 5) NO: 13-14, NC: 21-22
Note: The positive break of the type 5 contact block applies to the NC contacts
only. Connections to safety circuits should NOT be made using the NO
contacts.
To ensure positive breaking of the contacts, exceed the pre-travel by 1.5mm or
25˚ according to the model.
Maximum screw tightening torque 0.8Nm (8Kg cm)