(R) C FF-ST4 Series US Approved as Type 4 per IEC/EN 61496-1/2 Type 4 Safety Light Curtains Description The FF-ST4 Series is designed for hazardous point-of-operation or access detection in industrial machine safeguarding applications. Its enhanced output stage design provides longer cable length through M12 plugs. The Honeywell patented push-pull type OSSD outputs allow for low impedance at any time, while regular open collector type OSSD outputs have high impedance when OFF. As a result, the M12 limited wire section is no longer a constraint. ASIC technology provides fast response times compared to the micro-processor technology commonly used for safety light curtains. The FF-ST4 light curtain response times are worst-case response times including the sensor and the output stage, the embedded functions processing such as blanking or muting, and possible OSSD output failure modes. Fast response times contribute to shortened safety distances and reduced overall machine size. Some models offer flexible configuration of different mode of operations through the M12, 8 pole plug. The Honeywell patented inputs with automatic polarity recognition reduce the amount of wiring and increase the number of configurations while keeping the advantages of the pre-wired, off-the shelf M12 cord sets. The sturdy metal housing (including zamak end caps), and a small window that reduces exposure to the environment, allow the FFST4 to operate in most harsh duty applications. Accessories include mounting kits, connectors, power supply, and relay modules. Features Potential Applications * Type 4 per IEC61496-1/2, SIL2 per IEC61508 * Automotive plant floor industry * Resolutions: 14 mm, 30 mm, 80 mm * Food and beverage industry * Protection heights: 200 mm to 1400 mm (14 mm and 18 mm * Handling industry resolution) or 200 mm to 1800 mm (30 mm and 80 mm resolu- * Machine tool industry tion) * Packaging industry * Scanning ranges: 0 m to 3.5 m (14 mm resolution) or 0.25 mm to 10 m (other resolutions) * Patented, unique solid state safety OSSD outputs allow longer cable lengths * Patented, automatic polarity recognition inputs provide easy, last minute configuration * M12, 5 and 8 pole plugs * ASIC technology provides fast response times * Metal housing and reduced window size provide sturdy design * Optimized overall size with reduced inactive zones * Different function packages available * Optional AS-i Safe field module * Paper industry * Special machines FF-ST4 Series SPECIFICATIONS CharacteristicParameter Resolution (min. object detection size) 14 mm, 18 mm, 30 mm, 80 mm Nominal scanning range 0 m to 3.5 m (for 14 mm resolution); 0.25 m to 10 m (for 18 mm, 30 mm, 80 mm resolutions) Angle of divergence max. 5 above 3 m (as per IEC/EN 61496-2) Emitting light source infrared, pulsed, 880 nm Supply voltage 24 Vdc (20%) for the emitter and the receiver Power consumption 5 W max. for the emitter, 5 W max. for the receiver Output type 2 safety solid state outputs, push-pull/PNP type with Normally Open characteristics Response time see mounting dimensions drawing Switching capability 350 mA max. at 24 Vdc Restart time after power up >1 s (automatic mode) Restart time after beam release 80 ms (without EDM), 150 ms (with EDM) Leakage current 0.25 mA Load impedance 70 Ohm min., 5 kOhm max. Voltage drop <2.3 Vdc Load turn-on voltage 5 V min. on resistive loads, 7 V min. on inductive loads Test pulse width/recurrence 2 pulses (width 200 us and 75 us), separated by 300 us, frequency from 3.3 ms to 8 ms (depending on height) Protections short-circuits and cross-faults, overloads (0.4 A max./0 Vdc; 0.9 A max./24 Vdc), reversed polarity, micro-cut-off 10 ms (100% voltage breakdown, 10 Hz) Max. cable length 100 m [328.08 ft] (capacitance: 10 nF) External contact type relay contact, or static (solid state) PNP or static (solid state) NPN (automatic recognition - no push-pull output allowed) Filtering time 20 ms by default, 150 ms on the EDM input Voltage switching thresholds (high/low) 14.5 Vdc min., 4.5 Vdc (complies with IEC 61131-2, for type 2 sensors) Input current (high/low) 20 mA; 10 mA at 24 Vdc Max. voltage 29 Vdc Housing material aluminum alloy End cap material zamak Window material PMMA (Polymethyllethacrylate) FUNCTION PACKAGES ModelExternal DeviceAutomaticRestart MonitoringRestartInterlock (EDM) (AUTO) (RES) MutingOne or Two BeamAS-i (or Bypass) Floating BlankingSafe FF-ST4 Basic - X - - - X FF-ST4 Standard X X X - - - FF-ST4 Advanced M X X X X - - FF-ST4 Advanced B X X X - X - 2 www.honeywell.com/sensing Type 4 Safety Light Curtains MOUNTING DIMENSIONS (For reference only: mm/[in]) PH TH 87,4 [3.44] 42 [1.65] 32,5 [1.28] 12,4 [0.49] 55 [2.17] 35 [1.38] 15 [0.59] FF-ST4X_ _XM2 Protection Height PH (mm) 14 mm resolution 18 mm resolution 30 mm, 80 mm resolution Total Height TH (mm) Response Time (ms)* 14 mm, 18 mm resolution 30 mm resolution 80 mm resolution NA: not available (*) without blanking 02 03 04 05 06 07 08 09 10 12 14 16 18 206 210 222 242 302 306 318 338 398 402 414 434 494 498 510 530 590 594 606 626 686 690 702 722 782 786 798 818 894 914 974 978 990 1010 1166 1170 1182 1202 1358 1362 1374 1394 NA NA 1566 1586 NA NA 1758 1778 11 11 13.5 12 12 14.5 12.5 12.5 15.5 13 13 16 14 14 17 14.5 14.5 18 15.5 15.5 19 16 20 16.5 16.5 21 18 18 23 19.5 19.5 24.5 NA 21 26.5 NA 22 28.5 Honeywell Sensing and Control 3 FF-ST4 Series FF-ST4 Basic ORDERING INFORMATION Function package Automatic restart without external device monitoring Connection types M12/5 pole on emitter and receiver These on/off sensors are designed for the Honeywell FF-SRL60252 relay module or for the Honeywell FF-SRAC007S AS-i Safe field module. RECEIVER WIRING DIAGRAM 24 Vdc 0V 2.5A slow 4 3 5 1 2 1 = brown 2 = white 3 = blue 4 = black 5 = grey (Not used) Honeywell FF-SRL60252 or FF-SRAC007S 0V K1 K2 S12 1 3 POWER 2 S22 4 OSSDs FINGER DETECTION Resolution 14 mm, Scanning Range 0 m to 3.5 mResolution 18 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4A02AM2 200 FF-ST4B02AM2 300 FF-ST4A03AM2 300 FF-ST4B03AM2 400 FF-ST4A04AM2 400 FF-ST4B04AM2 500 FF-ST4A05AM2 500 FF-ST4B05AM2 600 FF-ST4A06AM2 600 FF-ST4B06AM2 700 FF-ST4A07AM2 700 FF-ST4B07AM2 800 FF-ST4A08AM2 800 FF-ST4B08AM2 1000 FF-ST4A10AM2 1000 FF-ST4B10AM2 1200 FF-ST4A12AM2 1200 FF-ST4B12AM2 1400 FF-ST4A14AM2 1400 FF-ST4B14AM2 HAND, LIMB OR BODY DETECTION Resolution 30 mm, Scanning Range 0.25 m to 10 mResolution 80 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4C02AM2 200 FF-ST4C02JM2 300 FF-ST4C03AM2 300 FF-ST4C03JM2 400 FF-ST4C04AM2 400 FF-ST4C04JM2 500 FF-ST4C05AM2 500 FF-ST4C05JM2 600 FF-ST4C06AM2 600 FF-ST4C06JM2 700 FF-ST4C07AM2 700 FF-ST4C07JM2 800 FF-ST4C08AM2 800 FF-ST4C08JM2 900 FF-ST4C09AM2 900 FF-ST4C09JM2 1000 FF-ST4C10AM2 1000 FF-ST4C10JM2 1200 FF-ST4C12AM2 1200 FF-ST4C12JM2 1400 FF-ST4C14AM2 1400 FF-ST4C14JM2 1600 FF-ST4C16AM2 1600 FF-ST4C16JM2 1800 FF-ST4C18AM2 1800 FF-ST4C18JM2 4 www.honeywell.com/sensing Type 4 Safety Light Curtains ORDERING INFORMATION FF-ST4 Function package Selectable automatic or manual restart interlock with external device monitoring Connection types Standard M12, 5 pole on emitter and M12, 8 pole on receiver These on/off sensors are designed to be directly interfaced to the machine final switching devices (e.g. contactors), eliminating the need for a dedicated interface module. RECEIVER WIRING DIAGRAM 0V 24 vdc 24 Vdc 2.5A slow 0V 6 7 5 4 8 1 3 2 1 = white 2 = brown 3 = green (Not used) 4 = yellow (Not used) 5 = gray 6 = pink 7 = blue 8 = red 24 vdc K1 K1 K2 2 7 POWER 1 8 AUTO/EDM 0V 0V K1 A1 K2 1 8 RES/EDM 5 Honeywell FF-SRE60292 K2 A3 6 OSSDs FINGER DETECTION Resolution 14 mm, Scanning Range 0 m to 3.5 mResolution 18 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4A02DM2 200 FF-ST4B02DM2 300 FF-ST4A03DM2 300 FF-ST4B03DM2 400 FF-ST4A04DM2 400 FF-ST4B04DM2 500 FF-ST4A05DM2 500 FF-ST4B05DM2 600 FF-ST4A06DM2 600 FF-ST4B06DM2 700 FF-ST4A07DM2 700 FF-ST4B07DM2 800 FF-ST4A08DM2 800 FF-ST4B08DM2 1000 FF-ST4A10DM2 1000 FF-ST4B10DM2 1200 FF-ST4A12DM2 1200 FF-ST4B12DM2 1400 FF-ST4A14DM2 1400 FF-ST4B14DM2 HAND, LIMB OR BODY DETECTION Resolution 30 mm, Scanning Range 0.25 m to 10 mResolution 80 mm, Scanning Range 0.25 m to10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4C02DM2 200 FF-ST4C02MM2 300 FF-ST4C03DM2 300 FF-ST4C03MM2 400 FF-ST4C04DM2 400 FF-ST4C04MM2 500 FF-ST4C05DM2 500 FF-ST4C05MM2 600 FF-ST4C06DM2 600 FF-ST4C06MM2 700 FF-ST4C07DM2 700 FF-ST4C07MM2 800 FF-ST4C08DM2 800 FF-ST4C08MM2 900 FF-ST4C09DM2 900 FF-ST4C09MM2 1000 FF-ST4C10DM2 1000 FF-ST4C10MM2 1200 FF-ST4C12DM2 1200 FF-ST4C12MM2 1400 FF-ST4C14DM2 1400 FF-ST4C14MM2 1600 FF-ST4C16DM2 1600 FF-ST4C16MM2 1800 FF-ST4C18DM2 1800 FF-ST4C18MM2 Honeywell Sensing and Control 5 FF-ST4 Series ORDERING INFORMATION FF-ST4 Advanced Function package Selectable automatic or manual restart interlock with external device monitoring and muting Connection types M12, 5 pole on emitter and M12, 8 pole on receiver M Muting (or bypass) allows objects to pass through the protection field without stopping the machine. Muting is permitted when personnel are not exposed to the hazard (e.g. manual loading/unloading) or when the hazard cannot be accessed without a stop (e.g. conveyor). NOTICE MUTING SENSOR OUTPUT TYPE The muting sensors can be any device with either relay outputs or soid state output. Devices with solid state push-pull outputs cannot be used. RECEIVER WIRING DIAGRAM 24 Vdc 24 vdc 2.5A slow 0V 6 7 5 4 8 1 3 2 1 = white 2 = brown 3 = green 4 = yellow 5 = gray 6 = pink 7 = blue 8 = red K1 2 7 POWER 1 8 AUTO/EDM 0V 24 vdc K1 K2 24 Vdc 0V 0V K1 1 8 RES/EDM A3 A1 K2 5 Honeywell FF-SRE60292 K2 6 OSSDs 3 4 MUTING FINGER DETECTION Resolution 14 mm, Scanning Range 0 m to 3.5 mResolution 18 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4A02VM2 200 FF-ST4B02VM2 300 FF-ST4A03VM2 300 FF-ST4B03VM2 400 FF-ST4A04VM2 400 FF-ST4B04VM2 500 FF-ST4A05VM2 500 FF-ST4B05VM2 600 FF-ST4A06VM2 600 FF-ST4B06VM2 700 FF-ST4A07VM2 700 FF-ST4B07VM2 800 FF-ST4A08VM2 800 FF-ST4B08VM2 1000 FF-ST4A10VM2 1000 FF-ST4B10VM2 1200 FF-ST4A12VM2 1200 FF-ST4B12VM2 1400 FF-ST4A14VM2 1400 FF-ST4B14VM2 HAND, LIMB OR BODY DETECTION Resolution 30 mm, Scanning Range 0.25 m to 10 mResolution 80 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4C02VM2 200 FF-ST4C02D1M2 300 FF-ST4C03VM2 300 FF-ST4C03D1M2 400 FF-ST4C04VM2 400 FF-ST4C04D1M2 500 FF-ST4C05VM2 500 FF-ST4C05D1M2 600 FF-ST4C06VM2 600 FF-ST4C06D1M2 700 FF-ST4C07VM2 700 FF-ST4C07D1M2 800 FF-ST4C08VM2 800 FF-ST4C08D1M2 900 FF-ST4C09VM2 900 FF-ST4C09D1M2 1000 FF-ST4C10VM2 1000 FF-ST4C10D1M2 1200 FF-ST4C12VM2 1200 FF-ST4C12D1M2 1400 FF-ST4C14VM2 1400 FF-ST4C14D1M2 1600 FF-ST4C16VM2 1600 FF-ST4C16D1M2 1800 FF-ST4C18VM2 1800 FF-ST4C18D1M2 6 www.honeywell.com/sensing Type 4 Safety Light Curtains ORDERING INFORMATION FF-ST4 Advanced B Function package Selectable automatic or manual restart interlock with external device monitoring and selectable one or two-beam floating blanking Connection types M12, 5 pole on emitter and M12, 8 pole on receiver The built-in floating blanking feature provides a means for the random inhibition of one or two light curtain beams. It is useful in applications where material or air-ejected parts randomly travel through or within the sensing field. Light beams may be disabled in an area where a fixture penetrates the light field, and stationary objects may not be allowed to protrude into the light curtain's sensing field. Any beam within the light curtain detection field may be blanked. ! WARNING incorrect safety distance when using floating blanking * Floating blanking increases the light curtain resolution and the response time. Therefore, the safety distance between the light curtain and the hazardous area shall be increased. * Refer to the installation manual for detailed information on resolution and calculating the safety distance. Failure to comply with these instructions could result in death or serious injury. RECEIVER WIRING DIAGRAM 24 vdc 24 Vdc 2.5A slow 0V 6 7 5 4 8 1 3 2 1 = white 2 = brown 3 = green 4 = yellow 5 = gray 6 = pink 7 = blue 8 = red K1 K2 2 7 POWER 1 8 AUTO/EDM 0V 24 vdc K1 K1 Honeywell FF-SRE60292 K2 A1 K2 1 8 RES/EDM 24 vdc 24 vdc 0V 0V 0V 0V A3 Not connected 5 6 OSSDs 3 4 BLANK 1 3 BLANK 2 4 3 4 NO BLANK FINGER DETECTION Resolution 14 mm, Scanning Range 0 m to 3.5 mResolution 18 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4A02RM2 200 FF-ST4B02RM2 300 FF-ST4A03RM2 300 FF-ST4B03RM2 400 FF-ST4A04RM2 400 FF-ST4B04RM2 500 FF-ST4A05RM2 500 FF-ST4B05RM2 600 FF-ST4A06RM2 600 FF-ST4B06RM2 700 FF-ST4A07RM2 700 FF-ST4B07RM2 800 FF-ST4A08RM2 800 FF-ST4B08RM2 1000 FF-ST4A10RM2 1000 FF-ST4B10RM2 1200 FF-ST4A12RM2 1200 FF-ST4B12RM2 1400 FF-ST4A14RM2 1400 FF-ST4B14RM2 HAND, LIMB OR BODY DETECTION Resolution 30 mm, Scanning Range 0.25 m to 10 mResolution 30 mm, Scanning Range 0.25 m to 10 m Protective Height (mm)Catalog ListingProtective Height (mm)Catalog Listing 200 FF-ST4C02RM2 900 FF-ST4C09RM2 300 FF-ST4C03RM2 1000 FF-ST4C10RM2 400 FF-ST4C04RM2 1200 FF-ST4C12RM2 500 FF-ST4C05RM2 1400 FF-ST4C14RM2 600 FF-ST4C06RM2 1600 FF-ST4C16RM2 700 FF-ST4C07RM2 1800 FF-ST4C18RM2 800 FF-ST4C08RM2 Honeywell Sensing and Control 7 FF-ST4 Series ACCESSORIES Catalog Listing Picture Description FF-SGZ001001 Basic mounting kit includes two M5 dovetail shape bolts, two M5 nuts and two rip-lock washers. (These are already included in the FF-ST package.) Order two kits for a complete set to use with emitter and receiver. FF-SXZ634189 Adjustable bracket kit includes two right angle brackets with four sets of M5 bolts, nuts and washers. Allows adjustments in azimuth directions of 4 with front access of the adjusting screws. Order two kits for a complete set to use with emitter and receiver. FF-SXZ634190 FF-SXZ634190-1 Kit includes two top/bottom, right angle, rotating brackets and four antivibration dampers (mounting hardware included). Allows adjustments in azimuth directions of 5. Order two kits for a complete set to use with emitter and receiver. * FF-SXZ634190: with anti-vibration dampers * FF-SXZ634190-1: without anti-vibration dampers Floor standing posts. FF-SYZPF FF-SYZPFM11 * 1300 mm high beam post. (Order two pieces for a complete light curtain set and two FF-SYZ634178 bracket kits.) * 1170 mm high plain mirror post (25% scanning range reduction). Recommended for light curtains with a protection height of up to 1000 mm. FF-SYZMIR102 FF-SYZMIR104 FF-SYZMIR106 FF-SYZMIR108 FF-SYZMIR110 FF-SYZMIR112 FF-SYZMIR114 FF-SYZMIR116 FF-SYZMIR118 Wall mount plain mirrors (25% scanning range reduction). Top and bottom brackets included (45 angle adjustment). Suitable for: * FF-ST_ _ 02 _ M2 * FF-ST_ _ 03 _ M2 and FF-ST_ _ 04 _ M2 * FF-ST_ _ 05 _ M2 and FF-ST_ _ 06 _ M2 * FF-ST_ _ 07 _ M2 and FF-ST_ _ 08 _ M2 * FF-ST_ _ 09 _ M2 and FF-ST_ _ 10 _ M2 * FF-ST_ _ 12 _ M2 * FF-ST_ _ 14 _ M2 * FF-ST_ _ 16 _ M2 * FF-ST_ _ 18 _ M2 FF-SXZCAM125U02-S FF-SXZCAM125U05-S FF-SXZCAM125U05-90S FF-SXZCAM125U10-S FF-SXZCAM125U10-90S M12 single-ended cordsets, female, 5 pin. * 2 m, straight * 5 m, straight * 5 m, right angle * 10 m, straight * 10 m, right angle FF-SXZCAM128U02-S FF-SXZCAM128U05-S FF-SXZCAM128U05-90S FF-SXZCAM128U10-S FF-SXZCAM128U10-90S 8 www.honeywell.com/sensing M12 single-ended cordsets, female, 8 pin. * 2 m, straight * 5 m, straight * 5 m, right angle * 10 m, straight * 10 m, right angle Type 4 Safety Light Curtains ACCESSORIES (continued) Catalog Listing Picture Description M12 screw connector, female, straight, 5 pin M12 screw connector, female, straight, 8 pin FF-SXZPWR050 ac to dc power supply (ordered separately as an option). * UL508 listed, UL1950, cUL/CSA-C22.2 No. 950-M90, EN/IEC 60950, EN 50178 (Class 2 rated for low power Installations) * Input voltage: 85 Vac to 264 Vac (43 Hz to 67 Hz) * Output voltage: 24 Vdc to 28 Vdc adjustable * Rated continuous load (at 60 C [140 F] max.): 2.1 A at 24 Vdc/ 1.8 A at 28 Vdc * Power: 50 W * Dimensions: 75 mm x 45 mm x 97 mm * DIN rail mounting * Weight: 240 g 20 mm / 0.79 in. 75 mm / 2.95 in. 35 mm / 1.38 in. 20 mm / 0.79 in. FF-SXZCOM125 FF-SXZCOM128 .58 91 45 mm FF-SRL60252 / 1.77 m m in. in. /3 97 .82 m m /3 in. Dual channel module for the FF-ST4 Basic models. * 22,5 mm width, 3 NO/1 NC internally redundant safety relay outputs (See separate product data sheet for detailed information.) FF-SRAC007S (input module) FF-SRAC5003 (DIN rail and panel quick mount base for AS-i flat cables) FF-SRE60292 FF-SRE30812 AS-i Safe input module for the FF-ST4 basic models. * Category 4 per EN954-1 and SIL3 per IEC61508 * Connection of the FF-ST4 emitter and receiver via a pair of M12 sockets * An external power supply is required to power the light curtain through the black flat cable. Order the DIN rail and panel quick mount base for AS-i flat cables: FF-SRAC5003 * Maximum cable length between light curtain and module is 10 m * 31 modules per master module * IP 67 protection rating * Dimensions: 110 mm x 45 mm x 70 mm (with the base) * Material: PA 6 (module), PBT (base) * CE approved, UL/CSA (application approval pending) * AS-i details: versions 2.11 and 3.0, profile S-0.B.E Expansion relay modules for the FF-ST4 Standard A and Standard M models. * 22,5 mm width, 4 NO/2 NC safety relay outputs * 90 mm width, 7 NO/1 NC safety relay outputs (See separate product data sheet for detailed information.) FF-SRL59022 Presence sensing device initiation module (PSDI) for the automatic machine cycle start to be used with light curtains with a resolution less than or equal to 30 m. (See separate product data sheet for detailed information.) Honeywell Sensing and Control 9 ! WaRNING Misuse of documentation * The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. * Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Warranty/Remedy Sales and Service Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell's standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer's sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, Minnesota 55422 www.honeywell.com 107160-3-EN FR26 GLO March 2009 Copyright 2009 Honeywell International Inc. All rights reserved.