DSC-5300 50 MHz Digital Storage Oscilloscope Applications The DSC-5300 Series Signal Generators are ideally suited for applications where value and quality are equally important such as for: zz Educational labs zz Technical schools zz Internal training facilities zz Hobbyists 20160712 Overview Features The Global Specialties DSC-5300 digital storage oscilloscope (DSO) is a portable benchtop instrument used for making measurements of signals and waveforms. The oscilloscope's bandwidth is capable of capturing up to 50 MHz signals with a real time sampling rate of up to 500 MSa/s. With up to 32 kpts of deep memory, it allows for capturing more details of a signal for analysis and display on the large color LCD display. zz Bandwidth: 50 MHz A Cal Test Electronics Company zz Single channel real-time sampling rate of up to 500 MSa/s zz 32k points of memory depth zz 7" Color TFT LCD display zz Trigger types: Edge, Pulse, Video, Slope and Alternative zz Auto measure 32 parameters (Voltage and Time) zz On board help menu zz Interface Options: USB, LAN, RS-232, Pass/Fail 22820 Savi Ranch Parkway Yorba Linda, CA 92887 800-572-1028 globalspecialties.com Specifications: All specification applies to 10X probe and All the DSC-5300 Digital Storage Oscilloscope. To verify that the oscilloscope meets specifications, the oscilloscope must first meet the following conditions: The oscilloscope must have been operating continuously for thirty minutes within the specified operating temperature. You must perform the Do Self Cal operation, accessible through the Utility menu, if the operating temperature changes by more than 5 C. The oscilloscope must be within the factory calibration interval All specifications are established unless noted "typical." Inputs Input Coupling Input Impedance Maximum Input voltage Ch to Ch Isolation (Both channels in same V/div setting) AC, DC, GND 1M2% || 16Pf3Pf, 400V DC+AC PK-PK1M input impedance X10CAT I >100:1 at 25MHz Probe Attenuator 1X,10X Probe Attenuator 1X,5X,10X,50X,100X, 500X,1000X Factors Set Vertical System Vertical Sensitivity Channel Voltage Offset Range Vertical Resolution Channels 2mV/div -10V/div(1-2-5 order) 2mV -200mV: 1.6V 8 bit 2 206mV - 10V: 40V Bandwidth 50MHz Single-shot Bandwidth 50MHz BW Flatness at BNC input DC -10% of rated BW: +/- 1dB 10% - 50% of rated BW: +/- 2dB 50% - 100% of rated BW: + 2dB/-3dB Lower frequency limit 10Hz(at input BNC) (AC -3dB) 0.6 Div for average of 10 Pk-Pk readings, Fixed Noise: Pk-Pk for 3K gain settings record 0.7 Div for average of 10 Pk-Pk readings, Variable gain settings SFDR including harmonics >=35dB (measured with FFT) 3.0%: 5mv/div to 10V/div in Fixed Gain DC Gain Accuracy Ranges 4.0%: 2mv/div Variable Gain Ranges DC Measurement Accuracy: [3%* |reading|+|offset| +1% *of |offset| All Gain settings +0.2div+2mv] 100mv/div DC Measurement Accuracy: [3%* |reading|+|offset| +1%* of |offset| All Gain settings +0.2div+100mv] 100mv/div Rise time <14ns Overshoot, Typical (using 500ps pulse) <10% with probe or BNC input w/ 50 Ohm feed thru Ch to Ch Skew (both channels in same V/div setting) Math operation <4ns (Equivalent to 2 minor divisions in smallest t/div) +, -, *, /, FFT Window mode: Hanning, Hamming, Blackman, Rectangular Sampling points: 1024 BW limited below 20MHz 40% (Note: 20MHz when using probe in x1) FFT Bandwidth limited Horizontal System Real Time Sampling Rate Equivalent Sampling Rate Measure Display Modes Timebase Accuracy Horizontal Range SingleChannel:500MSa/s,Double Channel: 250MSa/s( When timebase faster than 250ns/div) 50GSa/s (SDS1022DL:10GSa/s) MAIN, WINDOW, WINDOW ZOOM, ROLL, X-Y 100ppm measured over 1ms interval 1/2.5/5/25nS/DIV - 50S/DIV (According to the Scan Bandwidth) Scan: 100mS/DIV 50S/DIV (1-2.5-5 sequence) Trigger System Trigger Types Trigger Source Trigger Modes Trigger Coupling Trigger Level Range Trigger Displacement Trigger Level Accuracy (typical) applicable for the signal of rising and falling time 20ns Trigger Sensitivity Pulse Width Trigger Edge, Pulse Width, Video, Slope, Alternative CH1,CH2,EXT,EXT/5,AC Line Auto, Normal, Single AC, DC, LF rej, HF rej CH1,CH2: 6divisions from center of screen EXT: 1.2V EXT/5: 6V Pre-triggerMemory depth/2*sampling, Delay Trigger: 271.04DIV Internal (0.2 divxV/div)( within4 divisions from center of screen) EXT (6% of setting + 40 mV) EXT/5 (6% of setting + 200 mV) For fixed gain ranges 1 Divisions: DC-10MHz 1.5 Divisions: 10MHz - Max BW EXT: 200mVpp DC-10MHz, 300mVpp 10MHz - Max BW EXT/5: 1Vpp DC-10MHz, 1.5Vpp 10MHz - Max BW Trigger Modes: (,, )positive Pulse Width, (, , )Negative Pulse Width Pulse Width Range: 20ns - 10s Video Trigger Slope Trigger Alternative Trigger X-Y Mode X-pole Input / Y-Pole Input Sample Frequency Support signal Formats: PAL/SECAM, NTSC Trigger condition : odd field, even field, all lines, line Num (,, ) Positive slope, (,, ) Negative slope Time: 20ns-10s CH1 trigger type: Edge, Pulse, Video, Slope CH2 trigger type: Edge, Pulse, Video, Slope Channel 1 (CH1) / Channel 2 (CH2) XY mode has a breakthrough that trad oscilloscopes restrict sampling rate at 1MSa/s. Support 25Ksa/s250Msa/s adjusted. Hard Ware Frequency Counter Reading resolution 1Hz Accuracy 0.01% Range DC Couple, 10Hz to MAX Bandwidth Satisfying all Trigger signals(Except Pulse Signal Types width trigger and Video Trigger) Control Panel Function Auto Set Auto adjusting the Vertical, Horizontal system and Trigger Position Save/Recall Support 2 Group referenced Waveforms, 20 Group setups, 20 Group captured Waveforms internal Storage/Recall function and USB flash driver storage function. Measure System Auto Measure (32 Types) Vpp, Vmax, Vmin, Vamp, Vtop, Vbase, Vavg, Mean,Crms, Vrms, ROVShoot, FOVShoot, RPREShoot, FPREShoot, Rise time, Fall time, Freq, Period,+ Wid,Wid, Dut, Dut, BWid, Phase, FRR, FRF, FFR, FFF, LRR, LRF, LFR, LFF Cursor Measure Manual mode, Track mode and Auto mode General Specifications: Display System Color TFT 7.0in.(177.8mm)diagonal Liquid Crystal Display Resolution 480 horizontal by 234 vertical pixels Display Color 24bit Display Contrast Typical state 150:1 Backlight IntensityTypical state 300nit Wave display range 8 x 18 div Wave Display Mode Dots, Vector Persist Off, 1 sec, 2 sec, 5 sec, Infinite Menu Display 2 sec, 5 sec, 10 sec, 20 sec, Infinite Off,1min,2min,5min,10min,15min,3 Screen-Saver 0min,1hour,2hour,5hour Classical, Modern, Tradition, Skin Succinct waveform interpolation Sin(x)/xLinear Color model Normal , Invert Simplified Chinese, Traditional Chinese, English, Arabic, French, Language German, Russian, Portuguese Spanish, Japanese, Korean, Italian Display Mode Environments Temperature Cooling Humidity Height Power Supply Input Voltage Frequency Scope Power Operating:10 to +40 Not operating: -20 to +60 The fan forces it cold. Operating: 85%RH, 40, 24 hours Not operating: 85%RH, 65, 24 hours Operating: 3000m Not operating: 15,266m 100-240 VAC, CAT II, Auto selection 45Hz to 440Hz 50VA Max Mechanical Dimension length Width Height weight Standard Accessories: 1:1/10:1 probe (2 PCS) Power Cable Quick Start Guide USB Cable 323.1mm 135.6mm 157mm 2.5kg