© 2019 Kingbright. All Rights Reserved. Spec No: DSAF1856 / 1102013067 Rev No: V.10A Date: 04/03/2019 Page 2 / 4
Parameter Symbol Value Unit
Power Dissipation PD 75 mW
Reverse Voltage VR 5 V
Junction Temperature Tj 125 °C
Operating Temperature Top -40 To +85 °C
Storage Temperature Tstg -40 To + 8 5 °C
DC Forward Current IF 30 mA
Peak Forward Current IFM [1] 160 mA
Electrostatic Discharge Threshold (HBM) - 8000 V
Thermal Resistance (Junction / Ambient) Rth JA [2] 600 °C/W
Thermal Resistance (Junction / Solder point) Rth JS [2] 410 °C/W
Lead Solder Temperature [3] 260°C For 3 Seconds
Lead Solder Temperature [4] 260°C For 5 Seconds
ABSOLUTE MAXIMUM RATINGS at TA=25°C
ELECTRICAL / OPTICAL CHARACTERISTICS at TA=25°C
WP934EW/ID
Parameter Symbol Emitting Color
Value
Unit
Typ. Max.
Wavelength at Peak Emission IF = 10mA λpeak High Efficiency Red 627 - nm
Dominant Wavelength IF = 10mA λdom [1] High Efficiency Red 617 - nm
Spectral Bandwidth at 50% Φ REL MAX
IF = 10mA Δλ High Efficiency Red 45 - nm
Capacitance C High Efficiency Red 15 - pF
Forward Voltage IF = 10mA VF [2] High Efficiency Red 1.9 2.3 V
Reverse Current (VR = 5V) IR High Efficiency Red - 10 µA
Temperature Coefficient of λpeak
IF = 10mA, -10°C ≤ T ≤ 85°C TCλpeak High Efficiency Red 0.13 - nm/°C
Temperature Coefficient of λdom
IF = 10mA, -10°C ≤ T ≤ 85°C TCλdom High Efficiency Red 0.06 - nm/°C
Temperature Coefficient of VF
IF = 10mA, -10°C ≤ T ≤ 85°C TCV High Efficiency Red -1.9 - mV/°C
Notes:
1. The dominant wavelength (λd) above is the setup value of the sorting machine. (Tolerance λd : ±1nm. )
2. Forward voltage: ±0.1V.
3. Wavelength value is traceable to CIE127-2007 standards.
4. Excess driving current and / or operating temperature higher than recommended conditions may result in severe light degradation or premature failure.
Notes:
1. 1/10 Duty Cycle, 0.1ms Pulse Width.
2. Rth
JA ,Rth
JS Results from mounting on PC board FR4 (pad size ≥ 16 mm2 per pad).
3. 2mm below package base.
4. 5mm below package base.
5. Relative humidity levels maintained between 40% and 60% in production area are recommended to avoid the build-up of static electricity – Ref JEDEC/JESD625-A and JEDEC/J-STD-033.