M29W800AT M29W800AB 8 Mbit (1Mb x8 or 512Kb x16, Boot Block) Low Voltage Single Supply Flash Memory 2.7V to 3.6V SUPPLY VOLTAGE for PROGRAM, ERASE and READ OPERATIONS ACCESS TIME: 80ns PROGRAMMING TIME: 10s typical PROGRAM/ERASE CONTROLLER (P/E.C.) 44 - Program Byte-by-Byte or Word-by-Word - Status Register bits and Ready/Busy Output SECURITY PROTECTION MEMORY AREA INSTRUCTION ADDRESS CODING: 3 digits MEMORY BLOCKS 1 TSOP48 (N) 12 x 20mm SO44 (M) FBGA - Boot Block (Top or Bottom location) - Parameter and Main blocks BLOCK, MULTI-BLOCK and CHIP ERASE MULTI BLOCK PROTECTION/TEMPORARY UNPROTECTION MODES ERASE SUSPEND and RESUME MODES LFBGA48 (ZA) 8 x 6 solder balls Figure 1. Logic Diagram - Read and Program another Block during Erase Suspend LOW POWER CONSUMPTION VCC - Stand-by and Automatic Stand-by 100,000 PROGRAM/ERASE CYCLES per BLOCK 20 YEARS DATA RETENTION - Defectivity below 1ppm/year ELECTRONIC SIGNATURE 19 A0-A18 DQ0-DQ14 W - Manufacturer Code: 20h E - Top Device Code, M29W800AT: D7h G - Bottom Device Code, M29W800AB: 5Bh 15 DQ15A-1 M29W800AT M29W800AB BYTE RB RP VSS AI02599 March 2000 1/33 M29W800AT, M29W800AB Figure 2. TSOP Connections A15 A14 A13 A12 A11 A10 A9 A8 NC NC W RP NC NC RB A18 A17 A7 A6 A5 A4 A3 A2 A1 1 12 13 Figure 3. SO Connections 48 37 36 M29W800T M29W800B 24 25 A16 BYTE VSS DQ15A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC DQ11 DQ3 DQ10 DQ2 DQ9 DQ1 DQ8 DQ0 G VSS E A0 RB A18 A17 A7 A6 A5 A4 A3 A2 A1 A0 E VSS G DQ0 DQ8 DQ1 DQ9 DQ2 DQ10 DQ3 DQ11 1 44 2 43 3 42 4 41 5 40 6 39 7 38 8 37 9 36 10 35 11 M29W800T 34 12 M29W800B 33 13 32 14 31 15 30 16 29 17 28 18 27 19 26 20 25 24 21 22 23 RP W A8 A9 A10 A11 A12 A13 A14 A15 A16 BYTE VSS DQ15A-1 DQ7 DQ14 DQ6 DQ13 DQ5 DQ12 DQ4 VCC AI02181 AI02179 Table 1. Signal Names A0-A18 Address Inputs DQ0-DQ7 Data Input/Outputs, Command Inputs DQ8-DQ14 Data Input/Outputs DQ15A-1 Data Input/Output or Address Input E Chip Enable G Output Enable W Write Enable RP Reset/Block Temporary Unprotect RB Ready/Busy Output BYTE Byte/Word Organization VCC Supply Voltage VSS Ground NC Not Connected Internally DU Don't Use as Internally Connected 2/33 DESCRIPTION The M29W800A is a non-volatile memory that may be erased electrically at the block or chip level and programmed in-system on a Byte-by-Byte or Word-by-Word basis using only a single 2.7V to 3.6V VCC supply. For Program and Erase operations the necessary high voltages are generated internally. The device can also be programmed in standard programmers. The array matrix organisation allows each block to be erased and reprogrammed without affecting other blocks. Blocks can be protected against programing and erase on programming equipment, and temporarily unprotected to make changes in the application. Each block can be programmed and erased over 100,000 cycles. Instructions for Read/Reset, Auto Select for reading the Electronic Signature or Block Protection status, Programming, Block and Chip Erase, Erase Suspend and Resume are written to the device in cycles of commands to a Command Interface using standard microprocessor write timings. The device is offered in TSOP48 (12 x 20mm), SO44 and LFBGA48 0.8 mm ball pitch packages. M29W800AT, M29W800AB Figure 4. LFBGA Connections (Top view through package) 1 2 3 F A13 A12 A14 E A9 A8 D W C 4 5 6 7 8 A15 A16 BYTE DQ15 A-1 VSS A10 A11 DQ7 DQ14 DQ13 DQ6 RP DU DU DQ5 DQ12 VCC DQ4 RB DU A18 DU DQ2 DQ10 DQ11 DQ3 B A7 A17 A6 A5 DQ0 DQ8 DQ9 DQ1 A A3 A4 A2 A1 A0 E G VSS AI00656 Organisation The M29W800A is organised as 1M x8 or 512K x16 bits selectable by the BYTE signal. When BYTE is Low the Byte-wide x8 organisation is selected and the address lines are DQ15A-1 and A0-A18. The Data Input/Output signal DQ15A-1 acts as address line A-1 which selects the lower or upper Byte of the memory word for output on DQ0-DQ7, DQ8-DQ14 remain at High impedance. When BYTE is High the memory uses the address inputs A0-A18 and the Data Input/Outputs DQ0DQ15. Memory control is provided by Chip Enable E, Output Enable G and Write Enable W inputs. A Reset/Block Temporary Unprotection RP tri-level input provides a hardware reset when pulled Low, and when held High (at VID) temporarily unprotects blocks previously protected allowing them to be programed and erased. Erase and Program operations are controlled by an internal Program/ Erase Controller (P/E.C.). Status Register data output on DQ7 provides a Data Polling signal, and DQ6 and DQ2 provide Toggle signals to indicate the state of the P/E.C operations. A Ready/Busy RB output indicates the completion of the internal algorithms. Memory Blocks The devices feature asymmetrically blocked architecture providing system memory integration. Both M29W800AT and M29W800AB devices have an array of 19 blocks, one Boot Block of 16 KBytes or 8 KWords, two Parameter Blocks of 8 KBytes or 4 KWords, one Main Block of 32 KBytes or 16 KWords and fifteen Main Blocks of 64 KBytes or 32 KWords. The M29W800AT has the Boot Block at the top of the memory address space and the M29W800AB locates the Boot Block starting at the bottom. The memory maps are showed in Figure 5. Each block can be erased separately, any combination of blocks can be specified for multi-block erase or the entire chip may be erased. The Erase operations are managed automatically by the P/ E.C. The block erase operation can be suspended in order to read from or program to any block not being erased, and then resumed. Block protection provides additional data security. Each block can be separately protected or unprotected against Program or Erase on programming equipment. All previously protected blocks can be temporarily unprotected in the application. 3/33 M29W800AT, M29W800AB Table 2. Absolute Maximum Ratings (1) Symbol Value Unit Ambient Operating Temperature (3) -40 to 85 C TBIAS Temperature Under Bias -50 to 125 C TSTG Storage Temperature -65 to 150 C VIO (2) Input or Output Voltage -0.6 to 5 V Supply Voltage -0.6 to 5 V -0.6 to 13.5 V TA VCC V (A9, E, G, RP) (2) Parameter A9, E, G, RP Voltage Note: 1. Except for the rating "Operating Temperature Range", stresses above those listed in the Table "Absolute Maximum Ratings" may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those indicated in the Operating sections of this specification is not implied. Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability. Refer also to the STMicroelectronics SURE Program and other relevant quality documents. 2. Minimum Voltage may undershoot to -2V during transition and for less than 20ns during transitions. 3. Depends on range. Bus Operations The following operations can be performed using the appropriate bus cycles: Read (Array, Electronic Signature, Block Protection Status), Write command, Output Disable, Stan-by, Reset, Block Protection, Unprotection, Protection Verify, Unprotection Verify and Block Temporary Unprotection. See Tables 5 and 6. Command Interface Instructions, made up of commands written in cycles, can be given to the Program/Erase Controller through a Command Interface (C.I.). For added data protection, program or erase execution starts after 4 or 6 cycles. The first, second, fourth and fifth cycles are used to input Coded cycles to the C.I. This Coded sequence is the same for all Program/Erase Controller instructions. The 'Command' itself and its confirmation, when applicable, are given on the third, fourth or sixth cycles. Any incorrect command or any improper command sequence will reset the device to Read Array mode. Instructions Seven instructions are defined to perform Read Array, Auto Select (to read the Electronic Signature or Block Protection Status), Program, Block Erase, Chip Erase, Erase Suspend and Erase Resume. 4/33 The internal P/E.C. automatically handles all timing and verification of the Program and Erase operations. The Status Register Data Polling, Toggle, Error bits and the RB output may be read at any time, during programming or erase, to monitor the progress of the operation. Instructions are composed of up to six cycles. The first two cycles input a Coded sequence to the Command Interface which is common to all instructions (see Table 9). The third cycle inputs the instruction set-up command. Subsequent cycles output the addressed data, Electronic Signature or Block Protection Status for Read operations. In order to give additional data protection, the instructions for Program and Block or Chip Erase require further command inputs. For a Program instruction, the fourth command cycle inputs the address and data to be programmed. For an Erase instruction (Block or Chip), the fourth and fifth cycles input a further Coded sequence before the Erase confirm command on the sixth cycle. Erasure of a memory block may be suspended, in order to read data from another block or to program data in another block, and then resumed. When power is first applied or if VCC falls below VLKO, the command interface is reset to Read Array. M29W800AT, M29W800AB Table 3. Top Boot Block Addresses, M29W800AT Table 4. Bottom Boot Block Addresses, M29W800AB # Size (Kbytes) Address Range (x8) Address Range (x16) # Size (Kbytes) Address Range (x8) Address Range (x16) 18 16 FC000h-FFFFFh 7E000h-7FFFFh 18 64 F0000h-FFFFFh 78000h-7FFFFh 17 8 FA000h-FBFFFh 7D000h-7DFFFh 17 64 E0000h-EFFFFh 70000h-77FFFh 16 8 F8000h-F9FFFh 7C000h-7CFFFh 16 64 D0000h-DFFFFh 68000h-6FFFFh 15 32 F0000h-F7FFFh 78000h-7BFFFh 15 64 C0000h-CFFFFh 60000h-67FFFh 14 64 E0000h-EFFFFh 70000h-77FFFh 14 64 B0000h-BFFFFh 58000h-5FFFFh 13 64 D0000h-DFFFFh 68000h-6FFFFh 13 64 A0000h-AFFFFh 50000h-57FFFh 12 64 C0000h-CFFFFh 60000h-67FFFh 12 64 90000h-9FFFFh 48000h-4FFFFh 11 64 B0000h-BFFFFh 58000h-5FFFFh 11 64 80000h-8FFFFh 40000h-47FFFh 10 64 A0000h-AFFFFh 50000h-57FFFh 10 64 70000h-7FFFFh 38000h-3FFFFh 9 64 90000h-9FFFFh 48000h-4FFFFh 9 64 60000h-6FFFFh 30000h-37FFFh 8 64 80000h-8FFFFh 40000h-47FFFh 8 64 50000h-5FFFFh 28000h-2FFFFh 7 64 70000h-7FFFFh 38000h-3FFFFh 7 64 40000h-4FFFFh 20000h-27FFFh 6 64 60000h-6FFFFh 30000h-37FFFh 6 64 30000h-3FFFFh 18000h-1FFFFh 5 64 50000h-5FFFFh 28000h-2FFFFh 5 64 20000h-2FFFFh 10000h-17FFFh 4 64 40000h-4FFFFh 20000h-27FFFh 4 64 10000h-1FFFFh 08000h-0FFFFh 3 64 30000h-3FFFFh 18000h-1FFFFh 3 32 08000h-0FFFFh 04000h-07FFFh 2 64 20000h-2FFFFh 10000h-17FFFh 2 8 06000h-07FFFh 03000h-03FFFh 1 64 10000h-1FFFFh 08000h-0FFFFh 1 8 04000h-05FFFh 02000h-02FFFh 0 64 00000h-0FFFFh 00000h-07FFFh 0 16 00000h-03FFFh 00000h-01FFFh 5/33 M29W800AT, M29W800AB SIGNAL DESCRIPTIONS See Figure 1 and Table 1. Address Inputs (A0-A18). The address inputs for the memory array are latched during a write operation on the falling edge at Chip Enable E or Write Enable W. In Word-wide organisation the address lines are A0-A18, in Byte-wide organisation DQ15A-1 acts as an additional LSB address line. When A9 is raised to VID, either a Read Electronic Signature Manufacturer or Device Code, Block Protection Status or a Write Block Protection or Block Unprotection is enabled depending on the combination of levels on A0, A1, A6, A12 and A15. Data Input/Outputs (DQ0-DQ7). These Inputs/ Outputs are used in the Byte-wide and Word-wide organisations. The input is data to be programmed in the memory array or a command to be written to the C.I. Both are latched on the rising edge of Chip Enable E or Write Enable W. The output is data from the Memory Array, the Electronic Signature Manufacturer or Device codes, the Block Protection Status or the Status register Data Polling bit DQ7, the Toggle Bits DQ6 and DQ2, the Error bit DQ5 or the Erase Timer bit DQ3. Outputs are valid when Chip Enable E and Output Enable G are active. The output is high impedance when the chip is deselected or the outputs are disabled and when RP is at a Low level. Data Input/Outputs (DQ8-DQ14 and DQ15A- 1). These Inputs/Outputs are additionally used in the Word-wide organisation. When BYTE is High DQ8-DQ14 and DQ15A-1 act as the MSB of the Data Input or Output, functioning as described for DQ0-DQ7 above, and DQ8-DQ15 are 'don't care' for command inputs or status outputs. When BYTE is Low, DQ0-DQ14 are high impedance, DQ15A-1 is the Address A-1 input. Chip Enable (E). The Chip Enable input activates the memory control logic, input buffers, decoders and sense amplifiers. E High deselects the memory and reduces the power consumption to the stan-by level. E can also be used to control writing to the command register and to the memory array, while W remains at a low level. The Chip Enable must be forced to VID during the Block Unprotection operation. Output Enable (G). The Output Enable gates the outputs through the data buffers during a read operation. When G is High the outputs are High impedance. G must be forced to VID level during Block Protection and Unprotection operations. 6/33 Write Enable (W). This input controls writing to the Command Register and Address and Data latches. Byte/Word Organization Select (BYTE). The BYTE input selects the output configuration for the device: Byte-wide (x8) mode or Word-wide (x16) mode. When BYTE is Low, the Byte-wide mode is selected and the data is read and programmed on DQ0-DQ7. In this mode, DQ8-DQ14 are at high impedance and DQ15A-1 is the LSB address. When BYTE is High, the Word-wide mode is selected and the data is read and programmed on DQ0-DQ15. Ready/Busy Output (RB). Ready/Busy is an open-drain output and gives the internal state of the P/E.C. of the device. When RB is Low, the device is Busy with a Program or Erase operation and it will not accept any additional program or erase instructions except the Erase Suspend instruction. When RB is High, the device is ready for any Read, Program or Erase operation. The RB will also be High when the memory is put in Erase Suspend or Stan-by modes. Reset/Block Temporary Unprotect Input (RP). The RP Input provides hardware reset and protected block(s) temporary unprotection functions. Reset of the memory is achieved by pulling RP to VIL for at least tPLPX. When the reset pulse is given, if the memory is in Read or Stan-by modes, it will be available for new operations in tPHEL after the rising edge of RP. If the memory is in Erase, Erase Suspend or Program modes the reset will take t PLYH during which the RB signal will be held at VIL. The end of the memory reset will be indicated by the rising edge of RB. A hardware reset during an Erase or Program operation will corrupt the data being programmed or the sector(s) being erased. See Tables 15, 16, and Figure 11. Temporary block unprotection is made by holding RP at VID. In this condition previously protected blocks can be programmed or erased. The transition of RP from VIH to VID must slower than tPHPHH. See Tables 17, 18, and Figure 11. When RP is returned from VID to VIH all blocks temporarily unprotected will be again protected. VCC Supply Voltage. The power supply for all operations (Read, Program and Erase). VSS Ground. VSS is the reference for all voltage measurements. M29W800AT, M29W800AB DEVICE OPERATIONS See Tables 5, 6 and 7. Read. Read operations are used to output the contents of the Memory Array, the Electronic Signature, the Status Register or the Block Protection Status. Both Chip Enable E and Output Enable G must be low in order to read the output of the memory. A new operation is initiated either on the following edge of Chip Enable E or on any address transition with E at VIL. Write. Write operations are used to give Instruction Commands to the memory or to latch input data to be programmed. A write operation is initiated when Chip Enable E is Low and Write Enable W is Low with Output Enable G High. Addresses are latched on the falling edge of W or E whichever occurs last. Commands and Input Data are latched on the rising edge of W or E whichever occurs first. Output Disable. The data outputs are high impedance when the Output Enable G is High with Write Enable W High. Stan-by. The memory is in stan-by when Chip Enable E is High and the P/E.C. is idle. The power consumption is reduced to the stan-by level and the outputs are high impedance, independent of the Output Enable G or Write Enable W inputs. Automatic Stan-by. After 150ns of bus inactivity (no address transition, CE = VIL) and when CMOS levels are driving the addresses, the chip automatically enters a pseudo-stan-by mode where consumption is reduced to the CMOS stan-by value, while outputs still drive the bus (if G = VIL). Electronic Signature. Two codes identifying the manufacturer and the device can be read from the memory. The manufacturer's code for STMicroelectronics is 20h, the device code is D7h for the M29W800AT (Top Boot) and 5Bh for the M29W800AB (Bottom Boot). These codes allow programming equipment or applications to automatically match their interface to the characteristics of the M29W800A. The Electronic Signature is output by a Read operation when the voltage applied to A9 is at VID and address inputs A1 is Low. The manufacturer code is output when the Address input A0 is Low and the device code when this input is High. Other Address inputs are ignored. The codes are output on DQ0-DQ7. The Electronic Signature can also be read, without raising A9 to VID, by giving the memory the Instruction AS. If the Byte-wide configuration is selected the codes are output on DQ0-DQ7 with DQ8-DQ14 at High impedance; if the Word-wide configuration is selected the codes are output on DQ0-DQ7 with DQ8-DQ15 at 00h. Block Protection. Each block can be separately protected against Program or Erase on programming equipment. Block protection provides additional data security, as it disables all program or erase operations. This mode is activated when both A9 and G are raised to VID and an address in the block is applied on A12-A18. Block protection is initiated on the edge of W falling to VIL. Then after a delay of 100s, the edge of W rising to VIH ends the protection operations. Block protection verify is achieved by bringing G, E, A0 and A6 to VIL and A1 to VIH, while W is at VIH and A9 at VID. Under these conditions, reading the data output will yield 01h if the block defined by the inputs on A12-A18 is protected. Any attempt to program or erase a protected block will be ignored by the device. Block Temporary Unprotection. Any previously protected block can be temporarily unprotected in order to change stored data. The temporary unprotection mode is activated by bringing RP to VID. During the temporary unprotection mode the previously protected blocks are unprotected. A block can be selected and data can be modified by executing the Erase or Program instruction with the RP signal held at VID. When RP is returned to VIH, all the previously protected blocks are again protected. Block Unprotection. All protected blocks can be unprotected on programming equipment to allow updating of bit contents. All blocks must first be protected before the unprotection operation. Block unprotection is activated when A9, G and E are at VID and A12, A15 at VIH. Unprotection is initiated by the edge of W falling to VIL. After a delay of 10ms, the unprotection operation will end. Unprotection verify is achieved by bringing G and E to VIL while A0 is at VIL, A6 and A1 are at VIH and A9 remains at VID. In these conditions, reading the output data will yield 00h if the block defined by the inputs A12-A18 has been successfully unprotected. Each block must be separately verified by giving its address in order to ensure that it has been unprotected. 7/33 M29W800AT, M29W800AB Table 5. User Bus Operations (1) DQ0DQ7 DQ8DQ14 DQ15 A-1 A15 Data Output Data Output Data Output A12 A15 Data Output Hi-Z Address Input A9 A12 A15 Data Input Data Input Data Input A6 A9 A12 A15 Data Input Hi-Z Address Input X X X X X Hi-Z Hi-Z Hi-Z X X X X X X Hi-Z Hi-Z Hi-Z X X X X X X X Hi-Z Hi-Z Hi-Z VIL VID VIL Pulse V IH X X X X V ID X X X X X Blocks VID VID VIL Pulse V IH Unprotection (4) X X X X V ID VIH VIH X X X Block Protection Verify (2,4) VIL VIL VIH V IH X VIL VIH V IL V ID A12 A15 Block Protect Status(3) X X Block Unprotection Verify (2,4) VIL VIL VIH V IH X VIL VIH VIH V ID A12 A15 Block Protect Status(3) X X Block Temporary Unprotection X X X V ID X X X X X Operation E G W RP BYTE A0 A1 A6 A9 A12 A15 Read Word VIL VIL VIH V IH VIH A0 A1 A6 A9 A12 Read Byte VIL VIL VIH V IH VIL A0 A1 A6 A9 Write Word VIL VIH VIL V IH VIH A0 A1 A6 Write Byte VIL VIH VIL V IH VIL A0 A1 Output Disable VIL VIH VIH V IH X X Stan-by VIH X X V IH X X X X VIL Reset Block Protection (2,4) Note: 1. 2. 3. 4. X X X X X X = VIL or VIH. Block Address must be given an A12-A18 bits. See Table 7. Operation performed on programming equipment. Table 6. Read Electronic Signature (following AS instruction or with A9 = VID) Org. Wordwide Code E G W BYTE A0 A1 Other Addresses DQ0DQ7 DQ8DQ14 DQ15 A-1 VIL VIL V IH V IH VIL VIL Don't Care 20h 00h 0 M29W800AT VIL VIL V IH V IH VIH VIL Don't Care D7h 00h 0 M29W800AB VIL VIL V IH V IH VIH VIL Don't Care 5Bh 00h 0 Device Manufact. Code Device Code Table 7. Read Block Protection with AS Instruction E G W A0 A1 A12-A18 Other Addresses DQ0-DQ7 Protected Block VIL VIL V IH VIL VIH Block Address Don't Care 01h Unprotected Block VIL VIL V IH VIL VIH Block Address Don't Care 00h Code 8/33 M29W800AT, M29W800AB INSTRUCTIONS AND COMMANDS The Command Interface latches commands written to the memory. Instructions are made up from one or more commands to perform Read Memory Array, Read Electronic Signature, Read Block Protection, Program, Block Erase, Chip Erase, Erase Suspend and Erase Resume. Commands are made of address and data sequences. The instructions require from 1 to 6 cycles, the first or first three of which are always write operations used to initiate the instruction. They are followed by either further write cycles to confirm the first command or execute the command immediately. Command sequencing must be followed exactly. Any invalid combination of commands will reset the device to Read Array. The increased number of cycles has been chosen to assure maximum data security. Instructions are initialised by two initial Coded cycles which unlock the Command Interface. In addition, for Erase, instruction confirmation is again preceded by the two Coded cycles. Status Register Bits P/E.C. status is indicated during execution by Data Polling on DQ7, detection of Toggle on DQ6 and DQ2, or Error on DQ5 and Erase Timer DQ3 bits. Any read attempt during Program or Erase command execution will automatically output these five Status Register bits. The P/E.C. automatically sets bits DQ2, DQ3, DQ5, DQ6 and DQ7. Other bits (DQ0, DQ1 and DQ4) are reserved for future use and should be masked. See Tables 10 and 11. Data Polling Bit (DQ7). When Programming operations are in progress, this bit outputs the complement of the bit being programmed on DQ7. During Erase operation, it outputs a '0'. After completion of the operation, DQ7 will output the bit last programmed or a '1' after erasing. Data Polling is valid and only effective during P/E.C. operation, that is after the fourth W pulse for programming or after the sixth W pulse for erase. It must be performed at the address being programmed or at an address within the block being erased. If all the blocks selected for erasure are protected, DQ7 will be set to '0' for about 100s, and then return to the previous addressed memory data value. See Figure 13 for the Data Polling flowchart and Figure 12 for the Data Polling waveforms. DQ7 will also flag the Erase Suspend mode by switching from '0' to '1' at the start of the Erase Suspend. In order to monitor DQ7 in the Erase Suspend mode an address within a block being erased must be provided. For a Read Operation in Erase Suspend mode, DQ7 will output '1' if the read is attempted on a block being erased and the data value on other blocks. During Program operation in Erase Suspend Mode, DQ7 will have the same behavior as in the normal program execution outside of the suspend mode. Toggle Bit (DQ6). When Programming or Erasing operations are in progress, successive attempts to read DQ6 will output complementary data. DQ6 will toggle following toggling of either G, or E when G is low. The operation is completed when two successive reads yield the same output data. The next read will output the bit last programmed or a '1' after erasing. The toggle bit DQ6 is valid only during P/E.C. operations, that is after the fourth W pulse for programming or after the sixth W pulse for Erase. If the blocks selected for erasure are protected, DQ6 will toggle for about 100s and then return back to Read. DQ6 will be set to '1' if a Read operation is attempted on an Erase Suspend block. When erase is suspended DQ6 will toggle during programming operations in a block different to the block in Erase Suspend. Either E or G toggling will cause DQ6 to toggle. See Figure 14 for Toggle Bit flowchart and Figure 15 for Toggle Bit waveforms. Table 8. Commands Hex Code Command 00h Invalid/Reserved 10h Chip Erase Confirm 20h Reserved 30h Block Erase Resume/Confirm 80h Set-up Erase 90h Read Electronic Signature/ Block Protection Status A0h Program B0h Erase Suspend F0h Read Array/Reset 9/33 M29W800AT, M29W800AB Table 9. Instructions (1) Mne. Instr. Cyc. 1+ 1st Cyc. Addr. (3,7) X Data RD (2,4) Read/Reset Memory Array 3+ AS Auto Select 3+ Addr. (3,7) Addr. (3,7) Program 4 BE Block Erase 6 CE Chip Erase 6 Data ES (10) ER Erase Suspend 1 Erase Resume 1 Addr. (3,7) Data Addr. (3,7) Data 6th Cyc. 7th Cyc. Read Memory Array until a new write cycle is initiated. AAAh 555h AAAh Word 555h 2AAh 555h AAh 55h F0h Byte AAAh 555h AAAh Word 555h 2AAh 555h AAh 55h 90h Byte AAAh 555h AAAh Word 555h 2AAh 555h AAh 55h A0h Program Data Byte AAAh 555h AAAh AAAh 555h Word 555h 2AAh 555h 555h 2AAh Block Address Additional Block (8) AAh 55h 80h AAh 55h 30h 30h Byte AAAh 555h AAAh AAAh 555h AAAh Word 555h 2AAh 555h 555h 2AAh 555h AAh 55h 80h AAh 55h 10h Data Addr. (3,7) 5th Cyc. Byte Data Addr. (3,7) 4th Cyc. Read Memory Array until a new write cycle is initiated. Addr. (3,7) Data PG 3rd Cyc. F0h Data (4) 2nd Cyc. X B0h X 30h Read Electronic Signature or Block Protection Status until a new write cycle is initiated. See Note 5 and 6. Program Address Read Data Polling or Toggle Bit until Program completes. Note 9 Read until Toggle stops, then read all the data needed from any Block(s) not being erased then Resume Erase. Read Data Polling or Toggle Bits until Erase completes or Erase is suspended another time. Note: 1. Commands not interpreted in this table will default to read array mode. 2. A wait of tPLYH is necessary after a Read/Reset command if the memory was in an Erase or Program mode before starting any new operation (see Tables 15, 16 and Figure 11). 3. X = Don't Care. 4. The first cycles of the RD or AS instructions are followed by read operations. Any number of read cycles can occur after the command cycles. 5. Signature Address bits A0, A1, at V IL will output Manufacturer code (20h). Address bits A0 at VIH and A1, at VIL will output Device code. 6. Block Protection Address: A0, at V IL, A1 at VIH and A15-A18 within the Block will output the Block Protection status. 7. For Coded cycles address inputs A11-A18 are don't care. 8. Optional, additional Blocks addresses must be entered within the erase timeout delay after last write entry, timeout statuscan be verified through DQ3 value (see Erase Timer Bit DQ3 description). When full command is entered, read Data Polli ng or Toggle bit until Erase is completed or suspended. 9. Read Data Polling, Toggle bits or RB until Erase completes. 10. During Erase Suspend, Read and Data Program functions are allowed in blocks not being erased. 10/33 M29W800AT, M29W800AB Table 10. Status Register Bits DQ 7 Name Logic Level Definition '1' Erase Complete or erase block in Erase Suspend '0' Erase On-going DQ Program Complete or data of non erase block during Erase Suspend DQ Program On-going Data Polling '-1-0-1-0-1-0-1-' DQ 6 Toggle Bit '-1-1-1-1-1-1-1-' 5 4 3 2 Program Complete Erase Complete or Erase Suspend on currently addressed block Indicates the P/E.C. status, check during Program or Erase, and on completion before checking bits DQ5 for program or Erase Success. Successive reads output complementary data on DQ6 while Programming or Erase operations are on-going. DQ6 remains at constant level when P/E.C. operations are completed or Erase Suspend is acknowledged. '1' Program or Erase Error '0' Program or Erase On-going '1' Erase Timeout Period Expired P/E.C. Erase operation has started. Only possible command entry is Erase Suspend (ES). '0' Erase Timeout Period On-going An additional block to be erased in parallel can be entered to the P/E.C. '-1-0-1-0-1-0-1-' Chip Erase, Erase or Erase Suspend on the currently addressed block. Erase Error due to the currently addressed block (when DQ5 = `1'). Error Bit This bit is set to `1' in the case of Programming or Erase failure. Reserved Erase Time Bit Toggle Bit 1 Reserved 0 Reserved Note: Erase or Program On-going Note 1 Program on-going, Erase ongoing on another block or Erase Complete DQ Erase Suspend read on non Erase Suspend block Indicates the erase status and allows to identify the erased block Logic level '1' is High, '0' is Low. -0-1-0-0-0-1-1-1-0- represent bit value in successive Read operations. 11/33 M29W800AT, M29W800AB Table 11. Polling and Toggle Bits Mode DQ7 DQ6 DQ2 DQ7 Toggle 1 Erase 0 Toggle Note 1 Erase Suspend Read (in Erase Suspend block) 1 1 Toggle Erase Suspend Read (outside Erase Suspend block) DQ7 DQ6 DQ2 Erase Suspend Program DQ7 Toggle N/A Program Note: 1. Toggle if the address is within a block being erased. '1' if the address is within a block not being erased. Toggle Bit (DQ2). This toggle bit, together with DQ6, can be used to determine the device status during the Erase operations. It can also be used to identify the block being erased. During Erase or Erase Suspend a read from a block being erased will cause DQ2 to toggle. A read from a block not being erased will set DQ2 to '1' during erase and to DQ2 during Erase Suspend. During Chip Erase a read operation will cause DQ2 to toggle as all blocks are being erased. DQ2 will be set to '1' during program operation and when erase is complete. After erase completion and if the error bit DQ5 is set to '1', DQ2 will toggle if the faulty block is addressed. Error Bit (DQ5). This bit is set to '1' by the P/E.C. when there is a failure of programming, block erase, or chip erase that results in invalid data in the memory block. In case of an error in block erase or program, the block in which the error occurred or to which the programmed data belongs, must be discarded. The DQ5 failure condition will also appear if a user tries to program a '1' to a location that is previously programmed to '0'. Other Blocks may still be used. The error bit resets after a Read/Reset (RD) instruction. In case of success of Program or Erase, the error bit will be set to '0'. Erase Timer Bit (DQ3). This bit is set to '0' by the P/E.C. when the last block Erase command has been entered to the Command Interface and it is awaiting the Erase start. When the erase timeout period is finished, after 50s to 90s, DQ3 returns to '1'. Coded Cycles The two Coded cycles unlock the Command Interface. They are followed by an input command or a confirmation command. The Coded cycles consist of writing the data AAh at address AAAh in the Byte-wide configuration and at address 555h in the Word-wide configuration during the first cycle. 12/33 During the second cycle the Coded cycles consist of writing the data 55h at address 555h in the Bytewide configuration and at address 2AAh in the Word-wide configuration. In the Byte-wide configuration the address lines A-1 to A10 are valid, in Word-wide A0 to A11 are valid, other address lines are 'don't care'. The Coded cycles happen on first and second cycles of the command write or on the fourth and fifth cycles. Instructions See Table 9. Read/Reset (RD) Instruction. The Read/Reset instruction consists of one write cycle giving the command F0h. It can be optionally preceded by the two Coded cycles. Subsequent read operations will read the memory array addressed and output the data read. A wait state of 10s is necessary after Read/Reset prior to any valid read if the memory was in an Erase mode when the RD instruction is given. The Read/Reset command is not accepted during Erase and erase Suspend. Auto Select (AS) Instruction. This instruction uses the two Coded cycles followed by one write cycle giving the command 90h to address AAAh in the Byte-wide configuration or address 555h in the Word-wide configuration for command set-up. A subsequent read will output the manufacturer code and the device code or the block protection status depending on the levels of A0 and A1. The manufacturer code, 20h, is output when the addresses lines A0 and A1 are Low, the device code, EEh for Top Boot, EFh for Bottom Boot is output when A0 is High with A1 Low. The AS instruction also allows access to the block protection status. After giving the AS instruction, A0 is set to VIL with A1 at VIH, while A12-A18 define the address of the block to be verified. A read in these conditions will output a 01h if the block is protected and a 00h if the block is not protected. Program (PG) Instruction. This instruction uses four write cycles. Both for Byte-wide configuration and for Word-wide configuration. The Program command A0h is written to address AAAh in the Byte-wide configuration or to address 555h in the Word-wide configuration on the third cycle after two Coded cycles. A fourth write operation latches the Address on the falling edge of W or E and the Data to be written on the rising edge and starts the P/E.C. Read operations output the Status Register bits after the programming has started. Memory programming is made only by writing '0' in place of '1'. Status bits DQ6 and DQ7 determine if programming is on-going and DQ5 allows verification of any possible error. Programming at an address not in blocks being erased is also possible during erase suspend. In this case, DQ2 will toggle at the address being programmed. M29W800AT, M29W800AB Table 12. AC Measurement Conditions Figure 6. AC Testing Load Circuit Input Rise and Fall Times 10ns Input Pulse Voltages 0 to 3V Input and Output Timing Ref. Voltages 0.8V 1.5V 1N914 Figure 5. AC Testing Input Output Waveform 3.3k DEVICE UNDER TEST 3V OUT CL = 30pF or 100pF 1.5V 0V AI01417 CL includes JIG capacitance AI01968 Table 13. Capacitance (1) (TA = 25 C, f = 1 MHz) Symbol C IN Parameter Input Capacitance COUT Output Capacitance Test Condition Min Max Unit V IN = 0V 6 pF VOUT = 0V 12 pF Note: Sampled only, not 100% tested. Table 14. DC Characteristics (TA = 0 to 70C, -20 to 85C or -40 to 85C; VCC = 2.7V to 3.6V) Symbol Parameter Test Condition ILI Input Leakage Current ILO Output Leakage Current ICC1 Supply Current (Read by Word) E = VIL, G = VIH, f = 6MHz ICC2 Supply Current (Read by Word) ICC3 Supply Current (Stan-by) Min Max Unit 0V VIN V CC 1 A 0V VOUT VCC 1 A 3 10 mA E = VIL, G = V IL, f = 6MHz 4.5 10 mA E = VCC 0.2V 30 100 A 20 mA Typ. ICC4 (1) Supply Current (Program or Erase) VIL Input Low Voltage -0.5 0.8 V VIH Input High Voltage 0.7 VCC VCC + 0.3 V VOL Output Low Voltage 0.45 V VOH Output High Voltage CMOS VID A9 Voltage (Electronic Signature) IID A9 Current (Electronic Signature) VLKO (1) Supply Voltage (Erase and Program lock-out) Byte program, Block or Chip Erase in progress IOL = 1.8mA IOH = -100A V CC -0.4V V 11.5 A9 = VID 30 2.0 12.5 V 100 A 2.3 V Note: 1. Sampled only, not 100% tested. 13/33 M29W800AT, M29W800AB Table 15. Read AC Characteristics (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol Alt Parameter Test Conditio n 80 90 V CC = 3.0V to 3.6V CL = 30pF VCC = 3.0V to 3.6V CL = 30pF Min Max Min Unit Max tAVAV tRC Address Valid to Next Address Valid E = VIL, G = VIL tAVQV tACC Address Valid to Output Valid E = VIL, G = VIL tAXQX tOH Address Transition to Output Transition E = VIL, G = VIL tBHQV tFHQV BYTE Switching High to Output Valid 50 50 ns tBLQZ tFLQZ BYTE Switching Low to Output High Z 50 50 ns tEHQX tOH Chip Enable High to Output Transition G = VIL tEHQZ (1) tHZ Chip Enable High to Output Hi-Z G = VIL tELBH tELBL tELFH tELFL t ELQV (2) tCE Chip Enable Low to Output Valid G = VIL t ELQX (1) tLZ Chip Enable Low to Output Transition G = VIL 0 0 ns tGHQX tOH Output Enable High to Output Transition E = VIL 0 0 ns tGHQZ (1) tDF Output Enable High to Output Hi-Z E = VIL 30 30 ns tGLQV (2) tOE Output Enable Low to Output Valid E = VIL 35 35 ns tGLQX (1) tOLZ Output Enable Low to Output Transition E = VIL tPHEL tRH RP High to Chip Enable Low tPLYH (1, 3) tRRB tREADY RP Low to Read Mode tPLPX tRP 80 80 0 90 ns ns 0 ns 30 30 ns 5 5 ns 80 90 ns 0 0 ns 50 50 ns 10 500 Note: 1. Sampled only, not 100% tested. 2. G may be delayed by up to tELQV - tGLQV after the falling edge of E without increasing tELQV. 3. To be considered only if the Reset pulse is given while the memory is in Erase or Program mode. 14/33 ns 0 0 Chip Enable to BYTE Switching Low or High RP Pulse Width 90 10 500 s ns M29W800AT, M29W800AB Table 16. Read AC Characteristics (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol Alt Parameter Test Conditio n 100 120 V CC = 2.7V to 3.6V CL = 30pF VCC = 2.7V to 3.6V CL = 30pF Min Max Min Unit Max tAVAV tRC Address Valid to Next Address Valid E = VIL, G = VIL tAVQV tACC Address Valid to Output Valid E = VIL, G = VIL tAXQX tOH Address Transition to Output Transition E = VIL, G = VIL tBHQV tFHQV BYTE Switching High to Output Valid 50 60 ns tBLQZ tFLQZ BYTE Switching Low to Output High Z 50 60 ns tEHQX tOH Chip Enable High to Output Transition G = VIL tEHQZ (1) tHZ Chip Enable High to Output Hi-Z G = VIL tELBH tELBL tELFH tELFL t ELQV (2) tCE Chip Enable Low to Output Valid G = VIL t ELQX (1) tLZ Chip Enable Low to Output Transition G = VIL 0 0 ns tGHQX tOH Output Enable High to Output Transition E = VIL 0 0 ns tGHQZ (1) tDF Output Enable High to Output Hi-Z E = VIL 30 30 ns tGLQV (2) tOE Output Enable Low to Output Valid E = VIL 40 50 ns tGLQX (1) tOLZ Output Enable Low to Output Transition E = VIL tPHEL tRH RP High to Chip Enable Low tPLYH (1, 3) tRRB tREADY RP Low to Read Mode tPLPX tRP 100 100 0 ns 120 ns ns 0 0 Chip Enable to BYTE Switching Low or High RP Pulse Width 120 0 ns 30 30 ns 5 5 ns 100 120 ns 0 0 ns 50 50 ns 10 500 10 500 s ns Note: 1. Sampled only, not 100% tested. 2. G may be delayed by up to tELQV - tGLQV after the falling edge of E without increasing tELQV. 3. To be considered only if the Reset pulse is given while the memory is in Erase or Program mode. 15/33 16/33 Note: Write Enable (W) = High. BYTE DQ0-DQ7/ DQ8-DQ15 G E A0-A18/ A-1 ADDRESS VALID AND CHIP ENABLE tELBL/tELBH OUTPUT ENABLE tGLQX tGLQV tELQV tELQX tBHQV tAVQV VALID tAVAV DATA VALID tBLQZ VALID tGHQZ tGHQX tEHQX tEHQZ tAXQX AI02182 M29W800AT, M29W800AB Figure 7. Read Mode AC Waveforms M29W800AT, M29W800AB Table 17. Write AC Characteristics, W Controlled (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol Alt Parameter 80 90 VCC = 3.0V to 3.6V CL = 30pF VCC = 3.0V to 3.6V CL = 30pF Min Max Min Unit Max tAVAV tWC Address Valid to Next Address Valid 80 90 ns t AVWL tAS Address Valid to Write Enable Low 0 0 ns tDVWH tDS Input Valid to Write Enable High 35 45 ns tELWL tCS Chip Enable Low to Write Enable Low 0 0 ns Output Enable High to Write Enable Low 0 0 ns 500 500 ns 4 4 s tGHWL tPHPHH (1, 2) tVIDR RP Rise Time to VID tPHWL (1) tRSP RP High to Write Enable Low t PLPX tRP RP Pulse Width 500 500 ns tVCHEL tVCS VCC High to Chip Enable Low 50 50 s tWHDX tDH Write Enable High to Input Transition 0 0 ns tWHEH tCH Write Enable High to Chip Enable High 0 0 ns tWHGL tOEH Write Enable High to Output Enable Low 0 0 ns tWHRL (1) tBUSY Program Erase Valid to RB Delay tWHWL tWPH Write Enable High to Write Enable Low 30 30 ns tWLAX tAH Write Enable Low to Address Transition 45 45 ns tWLWH tWP Write Enable Low to Write Enable High 35 35 ns 90 90 ns Note: 1. Sampled only, not 100% tested. 2. This timing is for Temporary Block Unprotection operation. Block Erase (BE) Instruction. This instruction uses a minimum of six write cycles. The Erase Set-up command 80h is written to address AAAh in the Byte-wide configuration or address 555h in the Word-wide configuration on third cycle after the two Coded cycles. The Block Erase Confirm command 30h is similarly written on the sixth cycle after another two Coded cycles. During the input of the second command an address within the block to be erased is given and latched into the memory. Additional block Erase Confirm commands and block addresses can be written subsequently to erase other blocks in parallel, without further Coded cycles. The erase will start after the erase timeout period (see Erase Timer Bit DQ3 description). Thus, additional Erase Confirm commands for other blocks must be given within this delay. The input of a new Erase Confirm command will restart the timeout period. The status of the internal timer can be monitored through the level of DQ3, if DQ3 is '0' the Block Erase Command has been given and the timeout is running, if DQ3 is '1', the timeout has expired and the P/E.C. is erasing the Block(s). If the second command given is not an erase confirm or if the Coded cycles are wrong, the instruction aborts, and the device is reset to Read Array. It is not necessary to program the block with 00h as the P/E.C. will do this automatically before to erasing to FFh. Read operations after the sixth rising edge of W or E output the status register status bits. 17/33 M29W800AT, M29W800AB Table 18. Write AC Characteristics, W Controlled (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol Alt Parameter 100 120 VCC = 2.7V to 3.6V CL = 30pF VCC = 2.7V to 3.6V CL = 30pF Min tAVAV tWC Address Valid to Next Address Valid t AVWL tAS tDVWH tELWL Max Min Unit Max 100 120 ns Address Valid to Write Enable Low 0 0 ns tDS Input Valid to Write Enable High 45 50 ns tCS Chip Enable Low to Write Enable Low 0 0 ns Output Enable High to Write Enable Low 0 0 ns 500 500 ns 4 4 s tGHWL tPHPHH (1, 2) tVIDR RP Rise Time to VID tPHWL (1) tRSP RP High to Write Enable Low t PLPX tRP RP Pulse Width 500 500 ns tVCHEL tVCS VCC High to Chip Enable Low 50 50 s tWHDX tDH Write Enable High to Input Transition 0 0 ns tWHEH tCH Write Enable High to Chip Enable High 0 0 ns tWHGL tOEH Write Enable High to Output Enable Low 0 0 ns tWHRL (1) tBUSY Program Erase Valid to RB Delay tWHWL tWPH Write Enable High to Write Enable Low 30 30 ns tWLAX tAH Write Enable Low to Address Transition 45 50 ns tWLWH tWP Write Enable Low to Write Enable High 35 50 ns 90 90 ns Note: 1. Sampled only, not 100% tested. 2. This timing is for Temporary Block Unprotection operation. During the execution of the erase by the P/E.C., the memory accepts only the Erase Suspend ES and Read/Reset RD instructions. Data Polling bit DQ7 returns '0' while the erasure is in progress and '1' when it has completed. The Toggle bit DQ2 and DQ6 toggle during the erase operation. They stop when erase is completed. After completion the Status Register bit DQ5 returns '1' if there has been an erase failure. In such a situation, the Toggle bit DQ2 can be used to determine which block is not correctly erased. In the case of erase failure, a Read/Reset RD instruction is necessary in order to reset the P/E.C. Chip Erase (CE) Instruction. This instruction uses six write cycles. The Erase Set-up command 80h is written to address AAAh in the Byte-wide configuration or the address 555h in the Word- 18/33 wide configuration on the third cycle after the two Coded cycles. The Chip Erase Confirm command 10h is similarly written on the sixth cycle after another two Coded cycles. If the second command given is not an erase confirm or if the Coded cycles are wrong, the instruction aborts and the device is reset to Read Array. It is not necessary to program the array with 00h first as the P/E.C. will automatically do this before erasing it to FFh. Read operations after the sixth rising edge of W or E output the Status Register bits. During the execution of the erase by the P/E.C., Data Polling bit DQ7 returns '0', then '1' on completion. The Toggle bits DQ2 and DQ6 toggle during erase operation and stop when erase is completed. After completion the Status Register bit DQ5 returns '1' if there has been an Erase Failure. M29W800AT, M29W800AB Figure 8. Write AC Waveforms, W Controlled tAVAV A0-A18/ A-1 VALID tWLAX tAVWL tWHEH E tELWL tWHGL G tGHWL tWLWH W tWHWL tDVWH DQ0-DQ7/ DQ8-DQ15 tWHDX VALID VCC tVCHEL RB tWHRL AI02183 Note: Address are latched on the falling edge of W, Data is latched on the rising edge of W. Erase Suspend (ES) Instruction. The Block Erase operation may be suspended by this instruction which consists of writing the command B0h without any specific address. No Coded cycles are required. It permits reading of data from another block and programming in another block while an erase operation is in progress. Erase suspend is accepted only during the Block Erase instruction execution. Writing this command during Erase timeout will, in addition to suspending the erase, terminate the timeout. The Toggle bit DQ6 stops toggling when the P/E.C. is suspended. The Toggle bits will stop toggling between 0.1s and 15s after the Erase Suspend (ES) command has been written. The device will then automatically be set to Read Memory Array mode. When erase is suspended, a Read from blocks being erased will output DQ2 toggling and DQ6 at '1'. A Read from a block not being erased returns valid data. During suspension the memory will respond only to the Erase Resume ER and the Program PG instructions. A Program operation can be initiated during erase suspend in one of the blocks not being erased. It will result in both DQ2 and DQ6 toggling when the data is being programmed. A Read/Reset command will definitively abort erasure and result in invalid data in the blocks being erased. Erase Resume (ER) Instruction. If an Erase Suspend instruction was previously executed, the erase operation may be resumed by giving the command 30h, at any address, and without any Coded cycles. 19/33 M29W800AT, M29W800AB Table 19. Write AC Characteristics, E Controlled (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol Alt Parameter 80 90 VCC = 3.0V to 3.6V CL = 30pF VCC = 3.0V to 3.6V CL = 30pF Min Max Min Unit Max tAVAV tWC Address Valid to Next Address Valid 80 90 ns tAVEL tAS Address Valid to Chip Enable Low 0 0 ns tDVEH tDS Input Valid to Chip Enable High 35 45 ns tEHDX tDH Chip Enable High to Input Transition 0 0 ns tEHEL tCPH Chip Enable High to Chip Enable Low 30 30 ns tEHGL tOEH Chip Enable High to Output Enable Low 0 0 ns tEHRL (1) tBUSY Program Erase Valid to RB Delay tEHWH tWH Chip Enable High to Write Enable High 0 0 ns t ELAX tAH Chip Enable Low to Address Transition 45 45 ns tELEH tCP Chip Enable Low to Chip Enable High 35 35 ns Output Enable High Chip Enable Low 0 0 ns 500 500 ns 4 4 s tGHEL 80 90 ns tPHPHH (1, 2) tVIDR RP Rise TIme to VID tPHWL (1) tRSP RP High to Write Enable Low t PLPX tRP RP Pulse Width 500 500 ns tVCHWL tVCS VCC High to Write Enable Low 50 50 s tWLEL tWS Write Enable Low to Chip Enable Low 0 0 ns Note: 1. Sampled only, not 100% tested. 2. This timing is for Temporary Block Unprotection operation. POWER SUPPLY Power Up The memory Command Interface is reset on power up to Read Array. The device does not accept commands on the first rising edge of W, if both W and E are at VIL with G at VIH during power-up. Any write cycle initiation is blocked when VCC is below VLKO. 20/33 Supply Rails Normal precautions must be taken for supply voltage decoupling; each device in a system should have the VCC rail decoupled with a 0.1F capacitor close to the VCC and VSS pins. The PCB trace widths should be sufficient to carry the VCC program and erase currents required. M29W800AT, M29W800AB Table 20. Write AC Characteristics, E Controlled (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol Alt Parameter 100 120 VCC = 2.7V to 3.6V CL = 30pF VCC = 2.7V to 3.6V CL = 30pF Min tAVAV tWC Address Valid to Next Address Valid tAVEL tAS tDVEH Max Min Unit Max 100 120 ns Address Valid to Chip Enable Low 0 0 ns tDS Input Valid to Chip Enable High 45 50 ns tEHDX tDH Chip Enable High to Input Transition 0 0 ns tEHEL tCPH Chip Enable High to Chip Enable Low 30 30 ns tEHGL tOEH Chip Enable High to Output Enable Low 0 0 ns tEHRL (1) tBUSY Program Erase Valid to RB Delay tEHWH tWH Chip Enable High to Write Enable High 0 0 ns t ELAX tAH Chip Enable Low to Address Transition 45 50 ns tELEH tCP Chip Enable Low to Chip Enable High 35 50 ns Output Enable High Chip Enable Low 0 0 ns 500 500 ns 4 4 s tGHEL 90 90 ns tPHPHH (1,2) tVIDR RP Rise TIme to VID tPHWL (1) tRSP RP High to Write Enable Low t PLPX tRP RP Pulse Width 500 500 ns tVCHWL tVCS VCC High to Write Enable Low 50 50 s tWLEL tWS Write Enable Low to Chip Enable Low 0 0 ns Note: 1. Sampled only, not 100% tested. 2. This timing is for Temporary Block Unprotection operation. 21/33 M29W800AT, M29W800AB Figure 9. Write AC Waveforms, E Controlled tAVAV A0-A18/ A-1 VALID tELAX tAVEL tEHWH W tWLEL tEHGL G tGHEL tELEH E tEHEL tDVEH DQ0-DQ7/ DQ8-DQ15 tEHDX VALID VCC tVCHWL RB tEHRL AI02184 Note: Address are latched on the falling edge of E, Data is latched on the rising edge of E. Figure 10. Read and Write AC Characteristics, RP Related E tPHEL W tPHWL RB RP tPLPX tPHPHH tPLYH AI02091 22/33 M29W800AT, M29W800AB Table 21. Data Polling and Toggle Bit AC Characteristics (1) (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol tEHQ7V tEHQV tQ7VQV tWHQ7V tWHQV Parameter 80 90 VCC = 3.0V to 3.6V CL = 30pF VCC = 3.0V to 3.6V CL = 30pF Unit Min Max Min Max Chip Enable High to DQ7 Valid (Program, E Controlled) 10 2400 10 2400 s Chip Enable High to DQ7 Valid (Chip Erase, E Controlled) 1.0 60 1.0 60 sec Chip Enable High to Output Valid (Program) 10 2400 10 2400 s Chip Enable High to Output Valid (Chip Erase) 1.0 60 1.0 60 sec 35 ns Q7 Valid to Output Valid (Data Polling) 35 Write Enable High to DQ7 Valid (Program, W Controlled) 10 2400 10 2400 ms Write Enable High to DQ7 Valid (Chip Erase, W Controlled) 1.0 60 1.0 60 sec Write Enable High to Output Valid (Program) 10 2400 10 2400 s Write Enable High to Output Valid (Chip Erase) 1.0 60 1.0 60 sec Note: 1. All other timings are defined in Read AC Characteristics table. Table 22. Data Polling and Toggle Bit AC Characteristics (1) (TA = 0 to 70C, -20 to 85C or -40 to 85C) M29W800AT / M29W800AB Symbol tEHQ7V tEHQV tQ7VQV tWHQ7V tWHQV Parameter 100 120 VCC = 2.7V to 3.6V CL = 30pF VCC = 2.7V to 3.6V CL = 30pF Unit Min Max Min Max Chip Enable High to DQ7 Valid (Program, E Controlled) 10 2400 10 2400 s Chip Enable High to DQ7 Valid (Chip Erase, E Controlled) 1.0 60 1.0 60 sec Chip Enable High to Output Valid (Program) 10 2400 10 2400 s Chip Enable High to Output Valid (Chip Erase) 1.0 60 1.0 60 sec 50 ns Q7 Valid to Output Valid (Data Polling) 40 Write Enable High to DQ7 Valid (Program, W Controlled) 10 2400 10 2400 ms Write Enable High to DQ7 Valid (Chip Erase, W Controlled) 1.0 60 1.0 60 sec Write Enable High to Output Valid (Program) 10 2400 10 2400 s Write Enable High to Output Valid (Chip Erase) 1.0 60 1.0 60 sec Note: 1. All other timings are defined in Read AC Characteristics table. 23/33 24/33 DQ0-DQ6/ DQ8-DQ15 DQ7 W G E A0-A18/ A-1 LAST WRITE CYCLE OF PROGRAM OR ERASE INSTRUCTION DATA POLLING READ CYCLES tWHQ7V tEHQ7V tELQV tAVQV tQ7VQV IGNORE DQ7 DATA POLLING (LAST) CYCLE tGLQV ADDRESS (WITHIN BLOCKS) VALID VALID DATA OUTPUT VALID AI02185 MEMORY ARRAY READ CYCLE M29W800AT, M29W800AB Figure 11. Data Polling DQ7 AC Waveforms M29W800AT, M29W800AB Figure 12. Data Polling Flowchart Figure 13. Data Toggle Flowchart START START READ DQ2, DQ5 & DQ6 READ DQ5 & DQ7 at VALID ADDRESS DQ7 = DATA NO NO YES NO DQ5 =1 DQ5 =1 YES YES READ DQ7 DQ7 = DATA NO DQ2, DQ6 = TOGGLE YES READ DQ2, DQ6 YES DQ2, DQ6 = TOGGLE NO FAIL NO YES PASS FAIL PASS AI01369 AI01873 Table 23. Program, Erase Times and Program, Erase Endurance Cycles (TA = 0 to 70C; VCC = 2.7V to 3.6V) M29W800AT / M29W800AB Parameter Unit Typ Typical after (1) 100k W/E Cycles Chip Erase (Preprogrammed, VCC = 2.7V) 10 10 sec Chip Erase (VCC = 2.7V) 15 15 sec Main Block Erase (VCC = 2.7V) 1.5 Chip Program (Byte) (1) 10 10 sec Chip Program (Word) (1) 5 5 sec Byte/Word Program 10 10 s Min Program/Erase Cycles (per Block) 100,000 Max 15 sec cycles Note: 1. Excluded the time required to execute bus cycles sequence for program operation. 25/33 26/33 DATA TOGGLE READ CYCLE Note: All other timings are as a normal Read cycle. LAST WRITE CYCLE OF PROGRAM OF ERASE INSTRUCTION DQ0-DQ1,DQ3-DQ5,DQ7/ DQ8-DQ15 DQ6,DQ2 W G E A0-A18/ A-1 DATA TOGGLE READ CYCLE IGNORE STOP TOGGLE tWHQV tEHQV tAVQV MEMORY ARRAY READ CYCLE VALID VALID tGLQV tELQV VALID AI02186 M29W800AT, M29W800AB Figure 14. Data Toggle DQ6, DQ2 AC Waveforms M29W800AT, M29W800AB SECURITY PROTECTION MEMORY AREA The M29W800A features a security protection memory area. It consists of a memory block of 256 bytes or 128 words which is programmed in the ST factory to store a unique code that uniquely identifies the part. This memory block can be read by using the Read Security Data instruction (RDS) as shown in Table 24. Read Security Data (RDS) Instruction. This RDS uses a single write cycle instruction: the command B8h is written to the address AAh. This sets the memory to the Read Security mode. Any successive read attempt will output the addressed Security byte until a new write cycle is initiated. Table 24. Security Block Instruction Unlock Cycle Mne. Instr. Cyc. 2nd Cyc. 1st Cyc. RDS Read Security Data Addr. (1) AAh Data (2) B8h Read OTP Data until a new write cycle is initiated. 1 Note: 1. Address bits A10-A19 are don't care for coded address inputs. 2. Data bits DQ8-DQ15 are don't care for coded address inputs. Figure 15. Security Block Address Table BYTE Organisation (x8) TOP BOOT BLOCK BOTTOM BOOT BLOCK Security Memory Block Security Memory Block 000FFh 0E0FFh 00000h 0E000h WORD Organisation (x16) TOP BOOT BLOCK BOTTOM BOOT BLOCK Security Memory Block Security Memory Block 0007Fh 0E01Fh 00000h 0E000h AI02746 27/33 M29W800AT, M29W800AB Table 25. Ordering Information Scheme Example: M29W800AT 80 N 1 T Device Type M29 Operating Voltage W = 2.7 to 3.6V Device Function 800A = 8 Mbit (1Mb x8 or 512Kb x16), Boot Block Array Matrix T = Top Boot B = Bottom Boot Speed 80 = 80 ns 90 = 90 ns 100 = 100 ns 120 = 120 ns Package N = TSOP48: 12 x 20 mm M = SO44 ZA = LFBGA48: 0.8 mm pitch Temperature Range 1 = 0 to 70 C 5 = -20 to 85C 6 = -40 to 85 C Optio n T = Tape & Reel Packing Devices are shipped from the factory with the memory content bits erased to '1'. For a list of available options (Speed, Package, etc...) or for further information on any aspect of this device, please contact the ST Sales Office nearest to you. 28/33 M29W800AT, M29W800AB Table 26. Revision History Date Description November 1998 First issue February 1999 Removed TSOP48 Package Reverse Pinout March 1999 Program, Erase Times and Erase Endurance Cycles change 02/09/00 New document template Document type: from Preliminary Data to Data Sheet Program, Erase Times and Endurance Cycles change (Table 23) LFBGA Package Mechanical Data change (Table 29) LFBGA Package Outline drawing change (Figure 18) 03/06/00 Program Erase Times change (Table 23) 29/33 M29W800AT, M29W800AB Table 27. TSOP48 - 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Mechanical Data mm Symbol Typ inches Min Max A Typ Min 1.20 0.0472 A1 0.05 0.15 0.0020 0.0059 A2 0.95 1.05 0.0374 0.0413 B 0.17 0.27 0.0067 0.0106 C 0.10 0.21 0.0039 0.0083 D 19.80 20.20 0.7795 0.7953 D1 18.30 18.50 0.7205 0.7283 11.90 12.10 0.4685 0.4764 - - - - L 0.50 0.70 0.0197 0.0276 0 5 0 5 N 48 E e 0.50 0.0197 48 CP 0.10 0.0039 Figure 16. TSOP48 - 48 lead Plastic Thin Small Outline, 12 x 20mm, Package Outline A2 1 N e E B N/2 D1 A CP D DIE C TSOP-a Drawing is not to scale. 30/33 Max A1 L M29W800AT, M29W800AB Table 28. SO44 - 44 lead Plastic Small Outline, 525 mils body width, Package Mechanical Data mm inches Symbol Typ Min Max A 2.42 A1 A2 Min Max 2.62 0.0953 0.1031 0.22 0.23 0.0087 0.0091 2.25 2.35 0.0886 0.0925 B Typ 0.50 0.0197 C 0.10 0.25 0.0039 0.0098 D 28.10 28.30 1.1063 1.1142 E 13.20 13.40 0.5197 0.5276 - - - - 15.90 16.10 0.6260 0.6339 e 1.27 H 0.0500 L 0.80 - - 0.0315 - - 3 - - 3 - - N 44 CP 44 0.10 0.0039 Figure 17. SO44 - 44 lead Plastic Small Outline, 525 mils body width, Package Outline A2 A C B CP e D N E H 1 A1 L SO-b Drawing is not to scale. 31/33 M29W800AT, M29W800AB Table 29. LFBGA48 - 8 x 6 balls, 0.8 mm pitch, Package Mechanical Data mm inch Symbol Typ Min Max A Typ Min Max 1.350 A1 0.300 0.200 0.350 A2 0.750 b 0.0531 0.0118 0.0079 0.0138 1.000 0.0295 0.0394 0.300 0.550 0.0118 0.0217 D 9.000 8.800 9.200 0.3543 0.3465 0.3622 D1 5.600 - - 0.2205 - - ddd 0.150 0.0059 e 0.800 - - 0.0315 - - E 6.000 5.800 6.200 0.2362 0.2283 0.2441 E1 4.000 - - 0.1575 - - FD 1.700 - - 0.0669 - - FE 1.000 - - 0.0394 - - SD 0.400 - - 0.0157 - - SE 0.400 - - 0.0157 - - Figure 18. LFBGA48 - 8 x 6 balls, 0.8 mm pitch, Bottom View Package Outline D D1 FD FE SD SE E E1 BALL "A1" ddd A e b A2 A1 BGA-Z00 Drawing is not to scale. 32/33 M29W800AT, M29W800AB Information furnished is believed to be accurate and reliable. However, STMicroelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of STMicroelectronics. Specifications mentioned in this publication are subject to change without notice. This publication supersedes and replaces all information previously supplied. STMicroelectronics products are not authorized for use as critical components in lif e support devices or systems without express written approval of STMicroelectronics. The ST logo is registered trademark of STMicroelectronics 2000 STMicroelectronics - All Rights Reserved All other names are the property of their respective owners. STMicroelectronics GROUP OF COMPANIES Australia - Brazil - China - Finland - France - Germany - Hong Kong - India - Italy - Japan - Malaysia - Malta - Morocco Singapore - Spain - Sweden - Switzerland - United Kingdom - U.S.A . http://w ww.st.com 33/33