Features Unregulated Converter ECONOLINE 1 : 1 Input Range SMD Package Efficiency up to 75% 1kVDC Isolation Operating Temperature from -40C to +85C UL Certified DC/DC-Converter with 3 year Warranty Selection Guide tPart Number SMD Input Voltage (VDC) Output Voltage (VDC) Output Current (mA) Efficiency typ. (%) Max. Capacitive Load 5 5 200 75 1000F R1SE**-0505* * 1 Watt SMD Isolated Single Output add suffix -R for tape & reel packing Case and Pinning Options ** without marking denotes 5 pins out of 8 fitted with marking 8 denotes 8 pins out of 8 fitted Specifications (measured at TA = 25C, nominal input voltage full load and after warm up) Input Voltage Range 10% max. Voltage set Accuracy 100% Load/nominal Vin Line Regulation Low Line to High Line @ max. Load -2% typ. / 5% max. Load Regulation (10% to 100% Load) 1.2% typ. 10% typ. / 15% max. Ripple & Noise @ 20MHz BW 68mVp-p typ. / 100mVp-p max. Efficiency 100% Load 70% min. / 75% max. Operating Temperature -40C to + 85C Storage Temperature -55C to +125C Isolation Test Voltage (tested for 1 second) RoHS 2011/65/EU 6/6 E358085 1000VDC (rated for 1 minute***) UL-60950-1 Certified 500VAC / 60Hz Isolation Capacitance 75pF max. Isolation Resistance Viso = 500V R1SE 10 G min. Humidity 95% max. Operating Frequency Vin (nom.) 20kHz min. / 70 kHz max. Short-Circuit Protection 1 Second Weight 1.0g MTBF Using MIL-HDBK 217F (+90C) 172 x 10 hours Using MIL-HDBK 217F (+25C) 1022 x 10 hours Detailed Information see Application Notes chapter MTBF" Derating-Graph (Ambient Temperature) Certification UL General Safety Report: E358085-A2 UL60950-1 ***Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes. 100 80 Tolerance Envelopes Output Voltage +10% +5% +5% VNOM -2% -5% Typical Load Line Output Power (%) Tolerance Envelopes 60 40 Safe Operating Area 20 0 -40 0 50 100 85 150 Operating Temperature C 10% 50% 100% +Vout and -Vout load current (%) E-30 Refer to Application Notes REV: 1/2016 www.recom-power.com R1SE-0505 Series ECONOLINE DC/DC-Converter Typical Characteristics R1SE-0505 Efficiency/Load 100 Deviation/Load 90 25 Deviation from Nominal % 80 Efficiency % 70 60 50 40 30 20 10 20 15 10 5 0 -5 -10 0 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% 0% 10% 20% 30% 40% 50% 60% 70% 80% 90%100% Load % Load % Package Style and Pinning (mm) 10.70 12.75 6.70 7.00 Pin Connections 2.54x3 7 6 Pin # Function for 5 Pins 5 RECOM 12.00 1131 Pb 0.50 1 2 3 1 -Vin - Vin 2 +Vin +Vin 4 -Vout -Vout 5 +Vout +Vout 3, 6, 7 No Pin NC 8 NC NC NC= No Connection R1SE-0505 11.10 Function for 8 Pins 4 Footprint UNIT: mm TOL.: 0.25 mm 1.80 2.54 1.20 The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM's explicit written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV: 1/2016 E-31 R1SE 8 11.10