www.recom-power.com REV.: 4/2019 I-3
DC/DC Converter
Specifi cations (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ROF-78E
Series
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) automatic recovery
Short Circuit Input Current 200mA max.
Over Current Protection (OCP) >950mA typ. Hiccup mode
REGULATIONS
Parameter Condition Value
Output Accuracy ±5.0% max.
Line Regulation low line to high line ±1.0% max.
Load Regulation (2) 10% to 100% load ± 3.0% typ.
Transient Response 100% to 50% load
100% to 10% load
±100mV
±200mV
Optional Diode Protection Circuit
+Vout
GNDGND
ROF-78Exx-
5.0SMD
ROF-78Exx-
5.0SMD
+Vout=
+Vout - Vsd forward
GNDGND
+Vin +Vout
+Vin
+Vin
+Vin +Vout
GND
+Vout
GNDGND
ROF-78Exx-
5.0SMD
ROF-78Exx-
5.0SMD
+Vout=
+Vout - Vsd forward
GNDGND
+Vin +Vout
+Vin
GND
Add a blocking diode to Vout if
current can fl ow backwards into
the output, as this can damage the
converter when it is powered down.
The diode can either be fi tted
across the device if the source is
low impedance or fi tted in series
with the output (recommended).
Optional Protection 1: Optional Protection 2:
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range with derating @ free air convection (see graph) -40°C to +85°C
Operating Humidity non-condensing 5% - 95% RH max.
MTBF according to MIL-HDBK-217F, G.B. +25°C 3500 x 103 hours
-40 -20 0 20 40 70
75 85
60-30 -10 10 30 50 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Output Load [%]
Ambient Temperature [°C]
Derating Graph
(@ free air convection)
Notes:
Note2: Operation below 10% load will not harm the converter, but specifi cations may not be met