www.panduit.com
specifications
Category 6/Class E, 8-position, shielded jack module shall terminate 4-pair,
22 – 26 AWG, 100 ohm shielded twisted pair cable and shall not require use
of a punchdown tool. Shielded jack modules shall use a forward motion
termination method to optimize performance by maintaining cable pair
geometry while eliminating conductor untwist. The termination cap shall
be color-coded white to designate Category 6 performance and shall
include a universal label coded for T568A and T568B wiring schemes.
Mini-Com® TX6 PLUS Shielded
Jack Modules SPECIFICATION SHEET
applications
Mini-Com® TX6 PLUS Shielded Jack Modules
are a component of the TX6000 Shielded
Copper Cabling System. This end-to-end system
is interoperable and backwards compatible,
providing design flexibility to protect network
investments well into the future. With certified
performance to the ANSI/TIA-568-C.2 Category
6 and ISO 11801 Class E standards, this system
is ideal for today's high performance workstation
applications. With certified performance to the
ANSI/TIA-568-C.2 Category 6 and ISO 11801
Class E standards, these systems will support the
following applications:
• Ethernet 10BASE-T, 100BASE-T (Fast Ethernet),
1000BASE-T (Gigabit Ethernet)
• 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM
• Token Ring 4/16
• Digital video and broadband/baseband analog video
• Voice over Internet Protocol (VoIP)
technical information
Category 6/Class E
performance:
Exceeds ANSI/TIA-568-C.2 Category 6 and ISO 11801 Class E channel requirements
at swept frequencies up to 250 MHz
Meets ANSI/TIA-568-C.2 and ISO 11801 Category 6 component requirements at swept
frequencies up to 250 MHz
FCC compliance: Complies with ANSI/TIA-1096A (formerly FCC Part 68); contacts plated with
50 microinches of gold
IEC compliance: Meets IEC 60603-7 and IEC 60512-99-001
PoE compliance: Rated for 2500 cycles with IEEE 802.3af / 802.3at and proposed 802.3bt type 3 and type 4
for up to 100W
c(UL)us Listed: UL 1863, UL 1863 (Use as communications circuit accessory), CSA standard C22.2
UL 2043 (Suitable for use in air-handling spaces)
Operating temperature: -10° C to 65° C (14°F to 149°F)
RoHS compliance: Compliant
Conductor
termination range:
Wire cap compatible with 22 – 26 AWG solid or stranded cable with conductor insulation
diameters of 0.060 in. max and overall cable O.D. 0.200 in. to 0.330 in.; marine jack module
wire cap compatible with 22 AWG solid or stranded cable with 0.071 in. (1.80mm) maximum
insulated conductor outside diameter cable
key features and benefits
100% performance tested Confidence that each jack module will deliver the critical electrical
performance requirements
Utilizes enhanced
Giga-TX Technology
Optimizes performance by eliminating conductor untwist and reduces installation time
and expense
Improved termination cap Conductor retention slots simplify jack module termination
Integral shield Provides a 360° conductive path to ground shielded jack module with no additional
assembly required
Snap in grounding Shield provides seamless bonding of the jack module with Mini-Com® All Metal
Modular Patch Panels
Modular Shielded jack modules snap in and out of all Mini-Com® Faceplates, Metal Modular
Patch Panels, and Surface Mount Boxes for easy moves, adds, and changes
Individually serialized Marked with quality control number for future traceability
Identication Can be clearly identified with optional labels and icons for port identification
Shuttered version (optional): Integrated spring shuttered door keeps out dust and debris of un-mated RJ45 jack
modules automatically
Marine compatible
version available
Terminates to TX6000 Shielded S/FTP Marine Copper Cable, which includes a
durable flame-, oil-, UV- and MUD-resistant cable jacket; ideal for use in harsh
environments encountered in marine applications including ship and offshore/
onshore units
Termination tools (optional) EGJT termination tool ensures conductors are fully terminated by utilizing
a smooth forward motion without impact on critical internal components for
maximum reliability; TGJT termination tool ideal for high volume installations
Block out device (optional) Provides a simple and secure method to control access to data ports while not in use
TX6 PLUS Shielded Copper
Cabling System
Mini-Com® TX6 PLUS Shielded
Jack Modules
Jack module: CJS688TG*Y
Shuttered jack
module: CJSH688TG*Y
Marine jack
module: CJSM688TG
TX6 Shielded Copper Cable
CM, F/UTP: PFC6004***-KD
LSZH, F/UTP: PFL6004+-KD
LSZH, SF/UTP: PSFL6004+-KD
TX6000 Shielded S/FTP
Marine Copper Cable
LSZH: PSM6004BU++-LED
TX6A 10Gig Shielded CM/LSZH
Patch Cords
Foot lengths: STP6X^IG
Meter lengths: STP6X^^MIG
Mini-Com® Angled All Metal Modular
Patch Panels
24-port, 1 RU: CPA24BLY
48-port, 2 RU: CPA48BLY
72-port, 2 RU: CPA72BLY
Mini-Com® Flat All Metal
Modular Patch Panels
24-port, 1 RU: CP24BLY
48-port, 2 RU: CP48BLY
72-port, 2 RU: CP72BLY
Tools and Accessories
Jack module
termination tool: EGJT or TGJT
Wire snipping
tool: CWST
Wire stripping
tool: CJAST
Clear dust cap: MDC-C
Block out
device: PSL-DCJB-^^^
Phone icons: CIPIW-C+
Data icons: CIDIW-C+
*To designate color, add BU (Blue), RD (Red), YL
(Yellow), GR (Green) or VL (Violet). For part number
CJS688TGY (no designation), the color is black.
Offered in black only.
***To designate color, add suffix IG (International Gray)
or LG (Light Gray).
+To designate color, add suffix WH (White) or DG (Dark
Gray).
++To designate color, add suffix BL (Black) or IG (Inter-
national Gray). For other cable colors, contact customer
service.
^For lengths 3 to 20 feet (one foot increments) and 25,
30, 35, 40 feet, change the length designation in the part
number to the desired length. For standard cable colors
other than IG (International Gray), substitute the IG suffix
with BL (Black), BU (Blue), RD (Red), YL (Yellow), GR
(Green), OR (Orange) or VL (Violet). For example, the
part number for a blue 15-foot patch cord is STP6X15BU.
^^For lengths 1 to 10 meters (one meter increments)
and 1.5, 2.5, 15, 20 meters, change the length
designation in the part number to the desired length. For
standard cable colors other than IG (International Gray),
substitute the IG suffix with BL (Black), BU (Blue),
RD (Red), YL (Yellow), GR (Green), OR (Orange) or
VL (Violet). For example, the part number for a blue
15-meter patch cord is STP6X15MBU.
^^^To designate color other than Red, add suffix
BL (Black), BU (Blue), YL (Yellow), GR (Green),
OR (Orange), IW (Off White) or IG (International
Gray) at the end of the part number. 10/package.
Contact customer service for bulk packaged and/or
keyed jack modules and patch cords. Panduit
recommends installing shielded jack modules in
Mini-Com® All Metal Modular Patch Panels.
Test Results
©2015 Panduit Corp.
ALL RIGHTS RESERVED.
COSP315--WW-ENG
02/2016
Mini-Com® TX6 PLUS Shielded Jack Modules
WORLDWIDE SUBSIDIARIES AND SALES OFFICES
For a copy of Panduit product warranties, log on to www.panduit.com/warranty
PANDUIT CANADA
Markham, Ontario
cs-cdn@panduit.com
Phone: 800.777.3300
PANDUIT EUROPE LTD.
London, UK
cs-emea@panduit.com
Phone: 44.20.8601.7200
PANDUIT JAPAN
Tokyo, Japan
cs-japan@panduit.com
Phone: 81.3.6863.6000
PANDUIT SINGAPORE PTE. LTD.
Republic of Singapore
cs-ap@panduit.com
Phone: 65.6305.7575
PANDUIT AUSTRALIA PTY. LTD.
Victoria, Australia
cs-aus@panduit.com
Phone: 61.3.9794.9020
PANDUIT LATIN AMERICA
Guadalajara, Mexico
cs-la@panduit.com
Phone: 52.33.3777.6000
Contact Customer Service by email: cs@panduit.com
or by phone: 800.777.3300
Visit us at www.panduit.com
For more information
Dimensions are in inches (Dimensions in parenthesis are metric)
Mechanical Test Test Method Measurement Typical Test Results
Normal Force Load (grams) > 100
Vibration IEC 512-6d Circuit Resistance (mOhms) < 40
Shock IEC 512-6c Contact Disturbance (microsecond) < 5
Durability IEC 512-9a Circuit Resistance (mOhms) < 40
Mating/Un-mating IEC 512-13b Mating Force (N) < 20
Un-mating Force (N) < 20
Termination Cycles IEC 352 Number of Cycles > 20
Mating Cycles IEC 60603-7 Number of Plug Insertions > 2500
Electrical Test Test Method Measurement Typical Test Results
Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 20
Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed
Insulation Resistance IEC 512-3a Resistance (MOhms) > 500
Environmental Test Test Method Measurement Typical Test Results
Temperature Life IEC 512-9b Circuit Resistance (mOhms) < 40
Humidity IEC 512-11c Circuit Resistance (mOhms) < 40
Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40
Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40
Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40
0.62
(15.87)
0.74
(18.77)
1.50
(38.13)
Shielded Jack Module and Standard Shuttered Shielded Jack Module and
0.62
(15.87)
0.73
(18.64)
1.50
(38.10)