MP Series
• SIP SSR
• Ratings to 4A @ 280 VAC or 3A @ 60 VDC
• Triac (AC) or Transistor (DC) output
• DC Control
• Normally open (AC or DC) or normally closed output (DC only)
• CE Compliant to EN60950-1
PRODUCT SELECTION
Control Voltage 3A 3A 4A 3A
3-32 VDC MP120D3 MP240D3 MP240D4 MPDCD3
AVAILABLE OPTIONS
AC OUTPUT SPECIFICATIONS (1)
Description MP120D3 MP240D3 MP240D4
Operating Voltage (47-63Hz) [Vrms] 12-140 24-280 24-280
Transient Overvoltage [Vpk] 400 600 600
Maximum Off-State Leakage Current @ Rated Voltage [mArms] 5 5 5
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2) 200 200 200
Maximum Load Current [Arms] 3 3 4
Minimum Load Current [Arms] 0.02 0.02 0.02
Maximum Surge Current (16.6ms) [Apk] 90 90 130
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.6 1.6 1.6
Maximum I²t for fusing (8.3 msec) [A² sec] 36 36 72
Minimum Power Factor (with Maximum Load) 0.5 0.5 0.5
DC OUTPUT SPECIFICATIONS (1)
Description MPDCD3
Operating Voltage Range [VDC] 3-60
Maximum Load Current [Arms] 3
Minimum Load Current [Arms] 0.02
Maximum Surge Current for 1 second [Adc] 5
Maximum On-State Voltage Drop @ Rated Current [Vpk] 1.5
Maximum Off-State Leakage Current @ Rated Voltage [mA] 1.0
INPUT SPECIFICATIONS (1)
Description AC Output DC Output DC Output (-B)
Control Voltage Range 3-32 VDC 3-32 VDC 3-32 VDC
Must Turn On Voltage 3.0 VDC 3.0 VDC 1.0 VDC
Must Turn Off Voltage 1.0 VDC 1.0 VDC 3.0 VDC
Nominal Input Impedance 1500 Ohm 1500 Ohm 1500 Ohm
Maximum Turn-On Time [msec] 1/2 Cycle 100 µs 100 µs
Maximum Turn-Off Time [msec] 1/2 Cycle 100 µs 100 µs
GENERAL SPECIFICATIONS
Description Parameters
Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms
Minimum Insulation Resistance (@ 500 VDC) 109 Ohm
Maximum Capacitance, Input/Output 8 pF
Ambient Operating Temperature Range -40 to 80°C
Ambient Storage Temperature Range -40 to 125°C
Weight (typical) 0.7 oz. (20g)
Encapsulation Thermally Conductive Epoxy
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443,13.11.1
3) Inductive loads should be diode suppressed
MECHANICAL SPECIFICATIONS
WIRING DIAGRAM
THERMAL DERATE INFORMATION
AGENCY APPROVALS
Designed in accordanc e with the requirements of IEC 62314
EN60950 : Meets the requirem e nts of sections1.5: 1,7: 2.9: 2.10.5 .3: 4.2: 4.5: 4.7:
E116950 LR81689 (AC Output Onl y) 5900 UG (AC Outp ut Onl y)
Rev. 071712
ANNEX - ENVIROMENTAL INFORMATION