HHS40 DC-DC Series Data Sheet 40A Half-Brick Converter Features * * * * * * * * * * * * * Applications * * * * Distributed power architectures Telecommunications equipment LAN/WAN Data processing * * RoHS lead solder exemption compliant Low profile - 12.7 mm height Input/output isolation: 1500 VDC Basic insulation High efficiency - up to 88% at full load Start-up into high capacitive load Low conducted and radiated EMI Output overcurrent protection Output overvoltage protection Back-drive protection Overtemperature protection Remote sense Remote on/off (primary referenced), positive or negative logic Output voltage trim adjust UL60950-3rd/ CSA C22.2 60950-00, TUV EN60950-1, IEC60950-1 Description The HHS40 is a series of high efficiency, high-density, single output dc-dc converters for onboard conversion of standard telecom and datacom input voltages into isolated low voltage outputs in a through-hole mounting package. The two-board construction provides a cool environment for control components and the integrated metal substrate PCB provides superior thermal management for power components resulting in enhanced product reliability. A heat sink can be conveniently and effectively attached to the IMS base plate for operations in elevated ambient conditions or where airflow is minimal. Model Selection Model Input Voltage VDC HHS40ZE HHS40ZD 1 Input Current, Max 2 ADC 36 -75 4.5 Output Voltage Vout, VDC 3.3 36 -75 3.6 2.5 Output Rated Current I rated, ADC 40 Output Ripple/Noise, mV p-p Typical Efficiency @ I rated, % 150 88 40 150 88 NOTES: 1 Consult factory for availability 2 @ Vin min. FEB 16, 2006 revised to JUN 15, 2006 Page 1 of 11 www.power-one.com HHS40 DC-DC Series Data Sheet 40A Half-Brick Converter Absolute Maximum Ratings Stresses in excess of the absolute maximum ratings may cause performance degradation, adversely effect longterm reliability, and cause permanent damage to the converter. Table 1. Absolute Maximum Ratings Parameter Input voltage Conditions/Description Continuous Min Max 75 Units VDC 100 VDC Operating Temperature Transient (100 ms) Baseplate -40 115 C Storage Temperature Ambient -55 125 C ON/OFF Control Voltage Referenced to -Vin 10 VDC Environmental, Mechanical & Reliability Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Table 2. Environmental and Mechanical Specifications Parameter Operating Temperature Conditions/Description Baseplate Temperature Min -40 Nom Max 115 Units C Operating Humidity Relative humidity, non-condensing 95 % Storage Humidity Relative humidity, non-condensing 95 % Shock Halfsine wave (6ms), 3 axes 50 g Sinusoidal Vibration GR-63-CORE, Section 5.4.2 1 g Weight 1.9/54 Oz/g Water Washing Standard process Yes MTBF (calculated) Per Bellcore TR-NWT-000332 (Po=60W, Tc=40 C) 1,500 kHrs Dimensions (overall) 2.28(57.9) x 2.4(61) x 0.5(12.7) in (mm) FEB 16, 2006 revised to JUN 15, 2006 Page 2 of 11 www.power-one.com HHS40 DC-DC Series Data Sheet 40A Half-Brick Converter Isolation Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Table 3. Isolation Specifications Parameter Insulation Safety Rating Isolation Voltage Isolation Resistance Isolation Capacitance Conditions/Description Min Input to output, input to base plate Output to base plate 1500 707 10 Input to Output Nom Basic Max Units VDC VDC M pF 1000 Safety Regulatory Compliance Safety Agency Underwriters Laboratories TUV product Service CB report Standard Approved To: UL60950/CSA60950-00 Marking cULus TUV EN60950:2000 TUV PS Baurt mark IEC60950:1999 N/A. Input Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Table 4. Input Specifications 1 2 Parameter Input Voltage Turn-On Input Voltage 1 Turn-Off Input Voltage 1 Input over voltage protection Input Reflected Ripple Current 2 Conditions/Description Continuous Ramping Up Ramping Down Ramping up Full Load, 12 H source inductance Inrush Transient Vin = Vin.max Min 36 32.5 31.5 76 Nom 48 34 33 Max 75 35.5 34.5 84 50 Units VDC VDC VDC VDC mA p-p 1.0 A2s Refer to Figures 3 & 4 for actual characteristic waveforms. Refer to Figure 10 for test circuit. FEB 16, 2006 revised to JUN 15, 2006 Page 3 of 11 www.power-one.com HHS40 DC-DC Series Data Sheet 40A Half-Brick Converter Output Specifications All specifications apply over specified input voltage, output load, and temperature range, unless otherwise noted. Table 5. Output Specifications Parameter Output Voltage Setpoint Accuracy 2.5V 3.3V 1 Output Current Line Regulation Load Regulation Output Temperature Regulation Remote Sense Headroom 3 Ripple and Noise, DC to 20MHz 1, 5 Dynamic Regulation Peak Deviation Settling Time Peak Deviation Settling Time Turn-On Time (turn-on via application of Vin) Turn-On Time (turn-on via ON/OFF signal) Admissible Load Capacitance Output Current Limit Threshold 2 Short Circuit 2 Turn-On Overshoot Backdrive Protection Switching Frequency Overvoltage Protection, Clamp, Non Latching 3 Trim Range 1 Conditions/Description Vin = Vin.nom, Full Load Irated Vin.min to Vin.max, Irated Vin = Vin.nom, 10% to 100%Irated Min Nom Max Units %Vout %Vout Amps %Vout %Vout 125 35 2.00 1.5 40 .5 1 0.03 10 150 60 8 200 13 300 20 100 7 25 200 15 5 10 ms 13,000 150 14 5 F %Irated ARMS %Vout -2.00 -1.5 0.5 .25 .5 (TBaseplate) = -40 C to +115 C) Over line and load Tamb= 0 C to 85 C 75-100-75% load step change, to 1% error band di/dt = 0.1A/s di/dt = 1A/s 4 Time from Vin = UVLO to regulation band Time from ON/OFF signal to regulation band Irated, Nom Vin Vou t 0.97Vout.nom Hiccup 110 9 1 Yes 300 No damage to converter %/C %Vout mV p-p mVRMS %Vout s %Vout s ms Over all input voltage and load conditions 120 140 kHz %Vout Irated, Vin = Vnom 90 110 %Vout At Iout