Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A.
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Description
The SQ family of high power density, high efficiency
DC/DC converters deliver up to 25A in an industry
standard quarter brick footprint. They are targeted
specifically at the telecommunication, industrial
electronics, mobile telecommunication and distributed
power markets. With a wide input voltage range of 36-
75V they are available with output voltages of either
1.5, 1.8, 2.5, 3.3 or 5 Volts. All models feature an
input filter, input undervoltage lockout, output
overvoltage and overtemperature protection, output
current limiting and short circuit protection. These
converters are available either in a package that is
fully enclosed with a six-sided metal shield or an
alternative, open-frame construction. In both cases the
aluminum heat spreader design achieves very efficient
heat transfer with no hot spots. The use of patented
Flat Transformer technology and other patented
design concepts facilitate very low temperature rise.
The use of highly derated power devices help to
achieve high reliability, high performance and offer a
low cost solution to systems designers requiring
maximum power in small footprints.
Applications
Telecommunications
Data Communications
Wireless Communications
Networking Gear
Servers, Switches and Data Storage
Semiconductor Test Equipment
Distributed Power Architecture
Features
Delivers up to 25A in a quarter brick
High power density up to 90W/inch3
High efficiency Synchronous topology
Unique Flat Transformer Technology
No airflow or heat sink required
No minImum load required
Low profile of only 0.34 inch
1.5V, 1.8V, 2.5V, 3.3V or 5V output models
Wide input operating range 36-75V
-40°C to +100°C ambient operation
Input undervoltage lockout
Output overvoltage protection
Output current limit and short circuit protection
Remote On/Off pin (Negative logic
also available)
Output adjustment +/-10% range
Output remote sense feature
1500V, 10M input-to-output isolation
Enclosed construction with heat spreader for
low temperature rise
Also available in an open-frame construction
UL 60950 recognized, TUV EN60950 and
CSA C22.2 No. 60950-00 Certified and CE
marked
Meets conducted limits of FCC Class B and
CEI IEC61204-3 Class B with external filter
MTBF of 750,000 hours @ 50°C
(MIL-HDBK-217F)
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 2 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
CONVERTER SELECTION
Typical @ Ta=+25°C under nominal line voltage and full load conditions.
Input Output
Voltage (Volts) Current (A) Voltage Current
Efficiency
75% Load
Model Nominal Range No load Full load (Volts) (Amps) (%)
SQ100-48-1.5 48 36-75 0.040 0.9 1.5 25 87
For negative logic feature add designator N as suffix to model number, i.e., SQ100-48-1.5N
Consult factory for other output voltage configurations.
Outline Information and Summary Specifications
Pin Connection
Pin# Function
1 Vin +
2 On/Off
3 Vin -
4 Vout -
5 Sense -
6 Trim
7 Sense +
8 Vout +
All dimensions are in inches [mm]
Pin 4 and 8 are dia. 0.062 [1.57]
All other pins are all dia. 0.040 [1.02]
Pin material: Brass
Pin finish: Tin/Lead plated
Heat spreader (baseplate) material: Aluminum
Weight: 50.7g (1.8oz)
Tolerance
Inches Millimeters
XX ± 0.020 X ± 0.5
XXX ± 0.010 XX ± 0.25
Pin: ± 0.002 ± 0.05
Thermal derating for vertical orientation, Vin=54V
Output Current at 40°C (Amps) Output Current at 60°C (Amps)
200 LFM 300 LFM 200 LFM 300 LFM
Output
Voltage
(Volts) NoHeatsink With
Heatsink No Heatsink With
Heatsink No Heatsink With
Heatsink No Heatsink With
Heatsink
1.5 25 25 24 25 23 25 25 25
The information and specifications contained in this specification are believed to be accurate and reliable at the time
of publication. Specifications are subject to change without notice.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 3 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Electrical Specification
Typical test data at Ta=25°C, Vin=48V unless otherwise noted.
PARAMETER NOTES MIN TYP MAX UNIT
Absolute maximum rating
Input voltage 0 80 V
Operating case temperature -40 100 °C
Storage temperature -55 125 °C
Humidity 95 %
Input characteristics
Operating input voltage range 36 48 75 V
Turn on voltage threshold 34 35 36 V
Turn off voltage threshold 33 34 35 V
Transient withstand Transient duration: 100ms 100 V
Maximum input current 100% load, 36Vin 1.3 1.7 A
Off converter input current 36Vin 2.2 3.5 mA
Output characteristics
Output voltage set point 1.490 1.500 1.510 V
Output voltage line regulation 36~75 Vin ±1 ±1.1 %
Output voltage load regulation 10%-100%Load ±1 ±1.1 %
Output voltage trim range Percentage of normal output -20 +15 %
Output voltage ripple and noise 20Mz bandwidth, 100% Load, 48Vin 100 150 mV(pk-pk)
Output over power protection 110 120 140 %
Over-voltage protection 1.8 2.0 2.2 V
Output current range 0 25 A
Over-temperature protection 110 120 °C
Temperature coefficient ±0.05 %/°C
Capacitive Load 0 20,000 µF
Output dynamic characteristics
Startup time 5% to 95% of the output voltage 50 80 ms
Transient recovery time 25% load change 800 µs
Transient Peak Deviation 25% load change 10 %Vo
Efficiency (see efficiency curve)
100% load efficiency 48 Vin 85 %
Isolation characteristics
Isolation voltage (primary to secondary) 1minute 1500 VDC
Isolation voltage (primary to case) 1minute 1000 VDC
Isolation voltage (secondary to case) 1minute 1000 VDC
Isolation resistance 500VDC, Primary to secondary 10 M
Isolation capacitance Primary to secondary 1000 pF
Feature Characteristics
Switching frequency 340 360 380 KHz
ON/OFF control (Positive logic)
Converter On
Converter Off SQ100-48-1.5 2.5
-1.0 7
1.2 V
V
ON/OFF control (Negative logic)
Converter On
Converter Off SQ100-48-1.5N -1.0
2.5 1.2
7 V
V
Calculated MTBF Bellcore @50°C 1,000,000 Hrs
Weight 40 g
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 4 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Basic operation and functions
The SQ family uses FTT technology to achieve
high output current. The whole unit switches at
the fixed frequency for a predictable EMI
performance. Rectification of the transformer's
output is done by synchronous rectifiers to make
the unit work in a higher efficiency power
performance.
The SQ Brick has many standard controls and
protection functions.
Input ( pin1, pin3 )
Input power Vin(+) must be connected to Positive
input voltage pin1; Input power Vin(-) must be
connected to Negative input voltage pin3.
Output ( pin8, pin4 )
Output power Vout(+) must be connected to
Positive output voltage pin8; Output power Vout(-
) must be connected to Negative output voltage
pin4.
On/Off ( pin 2 )
Permits the user to maintain unit On/Off, in order
to properly sequence different power supplies
and reduce power consumption during the
standby condition. There are two remote control
options available, positive logic and negative logic
is referenced to Vin (-), and typical connections
are shown in Fig 1.
Fig. 1: Typical Circuit for On/Off Function
Pin 2 is the "Enable" pin, connecting a TTL
compatible pin. A TTL control signal to this pin,
according to the specification, will turn the unit on
or off.
The positive logic version turns on when pin 2 is
at logic high, and turns off when pin 2 is at logic
low. The unit is on when pin 2 is left open.
The negative logic version turns on when pin 2 is
at logic low and turns off when pin 2 is at logic
high. The pin 2 can be directed to Vin(-), to
enable automatic turn on to the unit without the
need of an external control signal.
Turn on timing vs. Input On/Off Pin is shown in
Figure 12, and the Turn off timing vs. Input On/Off
pin is shown in Figure 13.
Remote Sense ( pin 5, pin 7 )
Permits the user to maintain the accurate output
voltage at the remote load terminals regardless of
the line drop.
The Sense(-) (pin5) and Sense (+) (pin7) should
be connected at the load or at the point where the
regulation is needed. ( shown on Fig. 2)
Fig 2: Remote Sense Circuit
The remote sense feature of the unit
compensates for voltage drop occurring between
the output pins of the unit and load. The Sense(-)
(pin5) and Sense(+)(pin7) should be connected at
the load or at the point where regulation is
required.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 5 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
If remote Sense is not required, the Sense(-) pin
must be connected to the Vout(-) pin (pin4), and
the Sense(+) pin must be connected to the
Vout(+) pin(pin 8) to ensure the unit will regulate
at the specified output voltage. If these
connections are not made, the unit’s output
voltage will be higher than the specified value.
The unit output over voltage protection senses
the voltage across Vout(+) and Vout(-), and not
across the sense lines, so the resistance between
the output pins of the unit and the load should be
minimized to prevent unwanted triggering of the
OVP.
When using the remote sense feature, the output
voltage at the unit can be increased by as much
as 10% above the normal rating, in order to
maintain the required voltage across the load.
Therefore, the designer must consider this
condition.
Also when using the remote sense function, the
output power must be taken care of, as not to
exceed the maximum power capability of the unit.
Output voltage trim (pin 6)
Permits the user to adjust the output voltage up
or down to achieve the custom voltage or to make
the output voltage margining. The adjustment
range is from + 10% to -20%.
Output voltage can be adjusted up or down, by
connecting the Rtrim-up or Rtrim-down resistor as
shown. Rtrim-up makes the output voltage go up
to 10%; and the Rtrim-down makes the output
voltage go down to 20%. (see Fig.5 & Fig. 6)
Leave Trim pin ( Pin 6) open for normal output
voltage.
When trimming up, care must be taken, not to
exceed the unit OVP threshold. A typical circuit is
shown in Fig. 3.
Also, care must be taken not to exceed the unit’s
maximum allowable output power.
Fig 3. Trim Up Output Voltage Circuit
For Trim up resistor value, we list the reference
“Trim Up Resistance” for increasing the output
voltage for every 1 percent (see Trim Table 1).
Fig 5. shows “Trim Up Resistance” value chart.
Trimming down the output voltage for a typical
circuit, as shown on Fig. 4.
Fig 4. Trim Down Output Voltage Circuit
For Trim down resistance value, we list the
reference “Trim Down Resistance” for decreasing
output voltage for every 1 percent (see Trim
Table 2.).
Fig 6 shows “Trim Down Resistance” value chart.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 6 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
0
10
20
30
40
50
60
2 3 4 5 6 7 8 9 10
Trim up Vout change %
Rtrim-up (K)
Fig 5. Trim Up Resistance for reference chart
0
50
100
150
200
250
2345678910
Trim down Vout change %
Rtrim-dn (K)
Fig 6 Trim Down Resistance for reference chart
Rtrim-up(K) Vout(v) Trim up Vout %
57.6 1.53 2
36.5 1.545 3
26.1 1.56 4
19.6 1.575 5
15.4 1.59 6
12.4 1.605 7
10.2 1.62 8
8.45 1.635 9
6.98 1.65 10
Table 1: Rtrim-up resistor values.
Rtrim-dn(K) Vout(v) Trim down Vou
t %
255 1.47 2
165 1.455 3
118 1.44 4
93.1 1.425 5
75 1.41 6
61.9 1.395 7
53.6 1.38 8
45.3 1.365 9
39.2 1.35 10
Table 2: Rtrim-down resistor values.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 7 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Protection Features
Input Under-voltage Lockout ( IUV )
Input under voltage lockout ( IUV ) is standard
with the SQ unit. The unit will shut down when the
input voltage drops below a threshold, and the
unit will turn on when the input voltage goes to
the upper threshold.
The hysteretic voltage of the under voltage
protection is 2 V, normally from the 33.5V to
35.5V range.
Output Over-current Protection ( OCP )
The unit will shut down when the over current or
short circuit condition exists.
Once the OCP happens, the unit has shut down.
The attempted restart will continue indefinitely
until the over current or short circuit condition is
removed. When OCP happens, the output
voltage drops below 1.1V.
Figure 19 shows output voltage vs. output current
limit point and the unit’s shutdown point.
Input voltage has almost no effect on the current
limit point.
Output Over-voltage Protection ( OVP )
The unit will shut down when the output voltage
exceeds the over voltage threshold.
If the output voltage across Vout(+) (pin8) and
Vout(-) (pin4) exceeds the threshold of the OVP
circuitry, the unit has shut down which is caused
by an OVP circuit, and the unit will never restart,
and the output voltage is below 0.5V.
Over Temperature Protection ( OTP )
The unit will shut down when the base plate
temperature exceeds the protection threshold.
The unit will shut down under the base plate
temperature over a 110°C condition to protect the
unit from overheating. The OTP circuit will turn
the unit off when OTP happens. Once the unit
has shut down, it will restart at the cycle when the
base plate temperature goes down.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 8 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Application and consideration
Input Source Impedance
The unit has been designed to be stable with no
external capacitors when used in a low
inductance input and output circuit.
However in many applications, the inductance
with the distribution from the power source to the
input of the unit can affect the stability of the unit.
The addition of 47uF electrolytic capacitor with an
Esr < 1 (at 100khz) across the input can
ensure the stability of the unit. Also in many
applications, the user has to use decoupling
capacitors at the output load, to ensure the hold
up time for the load.
Safety Requirements and Considerations
The unit meets the American and International
safety regulatory requirement UL60950, TUV EN
60950, CSA C22.2 No. 60950-00. Basic
insulation is also provided between the input side
and the output side.
To meet safety agencies requirements, an input
line fuse must be used external to the unit. An 8A
fuse or less with a normal blow rate must be used
to meet the safety agencies requirements
If the input source is non-SELV ( ELV or a
hazardous voltage greater than 60 Vdc and less
than or equal to 75 Vdc), for the unit output to be
considered meeting the requirements of safety
extra low voltage (SELV), all of the following must
be met:
The input source is to be provided with
reinforced insulation from any hazardous
voltage, including the ac main.
The input pins of the unit are not operator
accessible.
For whole system, for safety agencies
requirements, and for the combination of
the unit’s input side (primary side) and the
unit’s output side (secondary side), verify
that under a single fault, hazardous
voltages do not appear at the unit’s output
side (secondary side).
Never ground either of the input pins of
the unit without grounding one of the
output pins. This may allow a non-SELV
voltage to appear between the output pin
and ground.
Electromagnetic Compatibility ( EMC )
EMC requirements must be met at the end
product and system level from the customer. As
there is no specific standards dedicated to the
EMC of board-mounted DC/DC converter, which
exist. However the SQ Family unit has been
tested for EMC requirement levels.
With the addition of a simple external filter (see
Fig 7.), the SQ Family unit passes the FCC class
B test conducted and CEI IEC61204-3 Class B.
Fig 7. External filter circuit for EMC.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 9 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
With this addition of an external simple filter
circuit, we can easily meet the EMC agencies
requirements. The EMC test result is shown on
Fig 8 below.
Fig 8. EMC conducted test result
Input Transient Withstand
SQ unit can withstand input transient voltage with
100v/100ms pulse, and never be damaged.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 10 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Characterization
General information
The SQ unit has many operational characterized
aspects, including thermal derating, efficiency,
start up and down timing parameter, overshoot,
output ripple & noise, dynamic response to load,
and over current protection curves.
The following pages contain specific plots or
waveforms associated with the unit. Additional
comments for specific data are provided below.
Test Conditions
All data presented herein were taken with the unit
soldered to a test board, which is a 0.060” thick
printed circuit board. All measurements require
an airflow wind with airflow meter measuring the
airflow LFM value.
For the input line, a 47uF/100V electrolytic
capacitor with Esr < 1 is used in the test. It is
better to make the 47uF capacitor closed to the
unit. For the output, a 10uf tantalum capacitor
with Esr < 0.12 and 1uF ceramic capacitor has
been used for the test.
Also it is better when these two capacitors are
close to the unit.
Note:
It is important to make sure that the components on
the unit do not exceed their rating.
Thermal Derating
For thermal derating, output current vs. ambient
temperature and airflow rates are tested, and the
test graphic is shown in Fig 23.
Ambient temperature was varied between 25°C
and 85°C, with airflow rates from 0 LFM to
300LFM (0 to 1.5 m/s).
Figure 23 shows that maximum output power
derating vs. ambient air temperature with airflow
rates of 0LFM through 300 LFM. At Vin=48v.
Figure 24 shows output power derating vs.
ambient aur temperature with airflow rates of
0LFM through 300LFM. At Vin=48v. ( Open
frame, without heatsink )
Efficiency
Efficiency vs. load current curve is given below.
The ambient temperature is 25°C, airflow is
200LFM(1m/s), and the input voltage is 36V, 48V,
and 75V conditions.
Figure 14 shows that Efficiency at nominal output
voltage vs. output current for various Input
voltage.
Start up
During the turn on transient using the On/Off pin
for full rated current and No load conditions, the
output voltage waveforms are given in the below.
Fig 9, Fig 10 and Fig 11 show that all different
kind of start up waveform.
Ripple and Noise
The output voltage waveform measured at No
load and Full load current, with 10uf tantalum and
1uf ceramic capacitor across to close the unit.
Figure 21 and Figure 22 show that output voltage
Ripple & Noise at Vin=48v and different load
condition.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 11 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Start up information
Scenario #1: Initial Start up from power supply
On/Off function enabled, the unit starts via input voltage Vin
See Fig 9.
Time Comments
t0 On/Off pin is On: system front-end power is switched
on, Vin to unit begins to rise.
t1 Vin crosses Under voltage lockout protection circuit
threshold: the unit enabled to be on
t2 The unit begins to turn on ( unit turn-on delay).
t3 Unit output voltage reaches 100% of normal
voltage.
For this example, the unit total start up time (t3- t1) is
typically 45ms.
Scenario #2: Initial Start up using On/Off Pin
With Vin previously powered, the unit starts via On/Off pin.
See Fig 10.
Time Comments
t0 Vin at nominal value.
t1 Arbitrary time when On/Off pin is enabled (Unit
enabled)
t2 End of unit turn-on delay
t3 Unit Vout reaches 100% of nominal voltage.
For this example, the unit total start up time (t3- t1) is
typically 70ms.
Scenario #3: Turn-off and restart using On/Off Pin
With Vin previously powered, the unit is disabled and then
enabled via On/Off pin. See Fig 11.
Time Comments
t0 Vin and Vout are at nominal values, On/Off pin
On.
t1 On/Off pin arbitrarily disabled, the unit output
falls to zero. Turn-on inhibit delay period
(100ms) is initiated, and On/Off pin action is
internally inhibited.
t2 On/Off pin is externally re-enabled.
If (t2- t1) 100ms, external action of On/Off pin
Is locked out by start up inhibit timer.
If (t2- t1) > 100ms, On/Off pin is On, the unit
begins turn-on; if off, the unit awaits On/Off pin
On signal; see Fig 11.
t3 Unit Vout reaches 100% of nominal voltage.
For the condition, (t2- t1) 100ms, the unit total start
up time (t5- t2) is typically 200ms. For (t2- t1) >
100ms , start up should be typically 45ms after release
of On/Off pin.
Fig 9. Start up waveform
Fig 10. Start up using On/Off pin
Fig 11. Turn off and restart using On/Off pin
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 12 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
On/Off Control Power Up/Down
Figure 12. Turn on timing vs. Input On/Off Pin.
Waveform 2 is output voltage, waveform 4 is negative
On/Off logic signal. At 48v input voltage, 20A output
current with 100uf output capacitance load.
Efficiency
55%
60%
65%
70%
75%
80%
85%
90%
95%
2.5 57.5 10 12.5 15 17.5 20 22.5 25
Load (A)
Eff. (%)
36V
50V
75V
Figure 14. Efficiency at nominal output voltage vs.
output current for various Input voltage. The unit
mounted on the 0.06” thick PCB with 300LFM air flow
(1.5/m) from pin 3 to pin 4 and Ta=25°C
Figure 13. Turn off timing vs. Input On/Off Pin.
Waveform 2 is output voltage, waveform 4 is negative
On/Off logic signal. At 48v input voltage, 20A output
current with 100uf output capacitance load.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 13 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Dynamic Response
Figure 15. Output voltage dynamic response at
Vin=48v Iout= 12~20A, 2.5A/us dynamic load.
waveform 2 is dynamic response via dynamic load.
waveform 4 is load current (2.5A/us); with 10uF output
capacitance load.
Overshoot
Figure 17. Output voltage over shoot and rise time at
Vin=48v, Iout = 0A; with 100uF output capacitance
load, and On/Off pin enabled to turn on the unit.
Figure 16. Output voltage dynamic response at
Vin=48v Iout= 12~20A, 2.5A/us dynamic load.
waveform 2 is dynamic response via dynamic load.
waveform 4 is load current (2.5A/us); with 2200uF
output capacitance load.
Figure 18. Output voltage over shoot and rise time at
Vin=48v, Iout=20A; with 100uF output capacitance
load, and On/Off enabled to turn on the unit.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 14 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Over Current and Short Circuit
0
0.5
1
1.5
2
2.5
0 5 10 15 20 25 30 35 40
output current (A)
output volt. (V)
Figure 19. Output voltage vs. output current limit point
and the unit shutdown point. Input voltage has almost
no effect on current limit point.
Ripple and Noise
Figure 21. Output voltage Ripple & Noise at Vin=48v,
Iout=0A, with 10uF tantalum cap. and 1uf ceramic
cap. output capacitance load.
Figure 20. Output waveform under short circuit
protection condition. Under 10m short circuit during
restart at 48Vin.
Figure 22. Output voltage Ripple & Noise, at Vin=48v,
Iout=20A, with 10uF tantalum cap. and 1uf ceramic
cap. output capacitance load.
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 15 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Temperature derating
Ta(¢X
50
00
10
5
25
20
(A)
15
Iout
25
C ) 75 100
Tc=100¢X
0.5M/S
Free Air
C
1.5M/S
1.0M/S
Figure 23. Maximum output power derating vs.
ambient air temperature with airflow rates of 0LFM
through 300 LFM. At Vin=48v. ( without heatsink )
00
5
25
(A)
10
15
Iout
25
C )Ta(¢X
50 75 100
20
Tc=100¢X
0.5M/S
Free Air
C
1.5M/S
1.0M/S
Figure 24. Maximum output power derating vs.
ambient air temperature with airflow rates of 0LFM
through 300 LFM. At Vin=48v. (Open Frame, without
heatsink )
Technical Specification
SQ100-48-1.5, SQ100-48-1.5N 48Vin 1.5Vout 25A
Data Sheet
Broadband TelCom Power, Inc. 1719 S. Grand Avenue, Santa Ana, CA 92705 U.S.A. P 16 of 16
Tel.: 714-259-4888 • Fax: 714-259-0840 • www.btcpower.com • Email: sales@btcpower.com • PS SQ100-48-1.5 Rev2 3-14-02
Input reflected ripple current
Figure 25. Test set up for measuring Input reflected
ripple currents, ic and is.
Figure 26. Input reflected ripple current ic waveform
without input inductor. At Vin=48v, Iout=25A,
50ma/Div. ( current probe with 50mv/div )
Figure 27. Input reflected ripple current is waveform
With 10uH input inductor. At Vin=48v, Iout=25A,
50ma/Div ( current probe with 50mv/div)
For More Information, Please Contact
sales@btcpower.com support@btcpower.com
www.btcpower.com