FORM AE043 ISS1 PRODUCT DATA SHEET Comus Group of Companies CONTACT FORM / STYLE 24.0 (.94) Contact open 16.0 (.63) Horizontal Differential angle 9.1o (.36) Max. Contact closed Pin 0.2o (.08) These switches operate when tilted from the horizontal position. The switch movement required to cause contact change (example off to on) is called the differential angle. It is very important when designing a tilt switch to allow for the differential angle and understand that when in the horizontal position the switch contact may be open or closed. Drawings not to scale All dimensions in mm (inches) nominal SPECIFICATION CONTACT FORM/STYLE SWITCHING VOLTAGE SWITCHING CURRENT SWITCHING CAPACITY (RESISTIVE) DIFFERENTIAL ANGLE CONTACT RESISTANCE OPERATING TEMPERATURE STORAGE TEMPERATURE CASE MATERIAL MOUNTING CLIPS FEATURES Max. Vac Max. A Max. VA Max. Deg Max. Deg. C Deg. C See above 240 1.0 120 10 -25 + 80 -25 + 85 Steel-tin plated 3BH AC only NOTE: When cutting or bending switch leads it is important that the glass seal is not damaged. The cutting or bending point should be no closer than 3mm to the glass to metal seal and the lead should be supported between the cutting or bending point and the glass to metal seal. PART NUMBER TILT SWITCH - Non Mercury Contacts CW3006-0 Rev. No. Revision Note Date Signature C Web Site 2001 1-2-01 RG As part of the company policy of continued product improvement, specifications may change without notice. Our sales office will be pleased to help you with the latest information on this product range and details of our full design and manufacturing service. All products are supplied to our standard conditions of sale otherwise agreed in writing. (c)2001 Copyright Comus Group of Companies The Comus Group of Companies consist of: Assemtech Europe Limited E. Bachem GmbH Comus International W. Gunther GmbH Gunther Belgium Gunther France S.T.G.