AF09Z-30-01-21 AF09Z-30-01-21 24-60V50/60HZ 20-60VDC Contactor -- General Information Extended Product Type AF09Z-30-01-21 Product ID 1SBL136001R2101 EAN 3471523113312 Catalog Description AF09Z-30-01-21 24-60V50/60HZ 20-60VDC Contactor Long Description AF09Z contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF..Z contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...250 V 50/60 Hz or 12...250 V DC. AF..Z contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF..Z contactors allow direct control by PLC-output 24 V DC 500 mA and obtain a reduced holding coil consumption. AF..Z contactors withstand short voltage dips and voltage sags (SEMI F47-0706 compliance) between 24...250 V 50/60 Hz AF..Z contactors have built-in surge protection and do not require additional surge suppressors The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks. (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available. -- Ordering Minimum Order Quantity 1 piece Customs Tariff Number 85364900 -- Popular Downloads Data Sheet, Technical Information 1SBC101402D0201 Instructions and Manuals 1SBC101027M6801 -- Dimensions Product Net Width 45 mm Product Net Depth / Length 77 mm Product Net Height 86 mm Product Net Weight 0.31 kg -- Technical Number of Main Contacts NO 3 Number of Main Contacts NC 0 AF09Z-30-01-21 2 Number of Auxiliary Contacts NO 0 Number of Auxiliary Contacts NC 1 Standards IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14 Rated Operational Voltage Auxiliary Circuit 690 V Main Circuit 690 V Rated Frequency (f) Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz Conventional Free-air Thermal Current (I th ) acc. to IEC 60947-4-1, Open Contactors q = 40 C 35 A acc. to IEC 60947-5-1, q = 40 C 16 A Rated Operational Current AC-1 (I e ) (690 V) 40 C 25 A (690 V) 60 C 25 A (690 V) 70 C 22 A Rated Operational Current AC-3 (I e ) (220 / 230 / 240 V) 60 C 9 A (380 / 400 V) 60 C 9 A (415 V) 60 C 9 A (440 V) 60 C 9 A (500 V) 60 C 9.5 A (690 V) 60 C 7 A Rated Operational Power AC-3 (P e ) (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW Rated Operational Current AC-15 (I e ) (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A Rated Short-time Withstand Current (I cw ) at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A Maximum Breaking Capacity cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A Maximum Electrical Switching Frequency AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour Rated Operational Current DC-13 (I e ) (110 V) 0.55 A / 60 W (220 V) 0.27 A / 60 W (400 V) 0.15 A / 60 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (125 V) 0.55 A / 69 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W Rated Insulation Voltage (U i ) acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V Rated Impulse Withstand Voltage (U imp ) 6 kV Maximum Mechanical Switching Frequency 3600 cycles per hour Rated Control Circuit Voltage (U c ) 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V Operate Time Between Coil De-energization and NC Contact Closing 13 ... 98 ms Between Coil De-energization and NO Contact Opening 11 ... 95 ms Between Coil Energization and NC Contact Opening 38 ... 90 ms Between Coil Energization and NO Contact Closing 40 ... 95 ms AF09Z-30-01-21 3 Connecting Capacity Main Circuit Flexible with Insulated Ferrule 1x 0.75 ... 4 mm Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm Flexible with Ferrule 1/2x 0.75 ... 6 mm Rigid 1/2x 1 ... 6 mm Connecting Capacity Auxiliary Circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm Connecting Capacity Control Circuit Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm Wire Stripping Length Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm Degree of Protection acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 Terminal Type Screw Terminals -- Environmental Ambient Air Temperature Close to Contactor for Storage -60 ... +80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C Climatic Withstand Category B according to IEC 60947-1 Annex Q Maximum Operating Altitude Permissible 3000 m Resistance to Vibrations acc. to IEC 60068-2-6 5 ... 300 Hz 4 g closed position / 2 g open position Resistance to Shock acc. to IEC 60068-2-27 Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g -- Technical UL/CSA General Use Rating UL/CSA (600 V AC) 25 A Horsepower Rating UL/CSA (120 V AC) Single Phase 3/4 Hp (240 V AC) Single Phase 1-1/2 Hp (200 ... 208 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 2 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 7-1/2 Hp Tightening Torque UL/CSA Auxiliary Circuit 11 in*lb Control Circuit 11 in*lb Main Circuit 13 in*lb -- Certificates and Declarations (Document Number) ABS Certificate ABS_15-GE1349500-PDA_90682247 BV Certificate BV_2634H24898B0 CB Certificate CB_SE-80871M3 CCC Certificate CCC_2010010304445624 cUL Certificate UL_20180227_E312527_7_1 Declaration of Conformity - CE 1SBD250000U1000 DNV Certificate DNV-GL_TAE00001AF-3 DNV GL Certificate DNV-GL_TAE00001AF-3 AF09Z-30-01-21 4 EAC Certificate EAC_RU C-FR ME77 B01010 Environmental Information 1SBD250147E1000 GL Certificate DNV-GL_TAE00001AF-3 GOST Certificate GOST_POCCFR.ME77.B07175.pdf Instructions and Manuals 1SBC101027M6801 KC Certificate KC_HW02016-15004A LR Certificate LRS_1300087E1 RINA Certificate RINA_ELE084013XG RMRS Certificate RMRS_1802705280 RoHS Information 1SBD251013E1000 UL Certificate UL_20140305-E312527_7_1 UL Listing Card E312527 -- Container Information Package Level 1 Units 1 piece Package Level 1 Width 87 mm Package Level 1 Depth / Length 79 mm Package Level 1 Height 47 mm Package Level 1 Gross Weight 0.31 kg Package Level 1 EAN 3471523113312 Package Level 2 Units 54 piece Package Level 2 Width 250 mm Package Level 2 Depth / Length 300 mm Package Level 2 Height 315 mm Package Level 2 Gross Weight 16.74 kg Package Level 3 Units 1296 piece -- Classifications Object Classification Code Q E-nummer 3210006 ETIM 4 EC000066 - Magnet contactor, AC-switching ETIM 5 EC000066 - Magnet contactor, AC-switching ETIM 6 EC000066 - Power contactor, AC switching ETIM 7 EC000066 - Power contactor, AC switching UNSPSC 39121529 -- Categories Low Voltage Products and Systems Control Products Contactors Block Contactors AF09Z-30-01-21 5