IRS26302DJ
www.irf.com © 2009 International Rectifier
8
Static Electrical Characteristics
(V
CC
-COM) = (V
B
-V
S
) = 15 V. TA = 25
°C
unless otherwise specified. The VIN and IIN parameters are referenced
to V
SS
and are applicable to all six channels. The VO and IO parameters are referenced to respective V
S
and
COM and are applicable to the respective output leads HO or LO. The V
CCUV
parameters are referenced to V
SS
.
The V
BSUV
parameters are referenced to V
S
. The PFCIo/BRIo and VPFC/ VBR are referenced to V
SS
and are
applicable to PFCout/BRout lead.
Symbol Definition Min Typ Max Units
Test Conditions
VIH Logic “1” input voltage 2.5 — —
VIL Logic “0” input voltage — — 0.8
V
IN,TH+
Input positive going threshold — 1.9 2.5
V
IN,TH-
Input negative going threshold 0.8 1 —
V
IT,TH+
Input positive going threshold 0.160 0.200 0.240
V
IT,TH-
Input negative going threshold 0.144 0.180 0.216
V
V
IT,HYS
ITRIP hysteresis — 20 — mV
V
PFCT,TH+
V
BRT,TH+
PFC/BR positive going threshold -0.144 -0.180 -0.216
V
PFCT,TH-
V
BRT,TH-
PFC/BR negative going threshold -0.160 -0.200 -0.240
V
V
PFCT,HYS
V
BRT,HYS
PFC/BR hysteresis — 20 — mV
V
GFT,TH+
GF positive going threshold 0.140 0.180 0.220
V
GFT,TH-
GF negative going threshold 0.150 0.200 0.240 V V
GFT
= V
DC
- V
GF
V
GFT,HYS
GF hysteresis — 20 — mV
V
RCIN,TH+
RCIN positive going threshold — 8 —
V
RCIN,HYS
RCIN hysteresis — 3 —
V
CC,UVTH+
V
CC
supply undervoltage positive going
threshold 10.2 11.1 12.0
V
CC,UVTH-
V
CC
supply undervoltage negative going
threshold 10.0 10.9 11.8
V
CC,UVHYS
V
CC
supply undervoltage hysteresis — 0.2 —
V
BS,UVTH+
V
BS
supply undervoltage positive going
threshold 10.2 11.1 12.0
V
BS, UVTH-
V
BS
supply undervoltage negative going
threshold 10.0 10.9 11.8
V
BS,UVHS
V
BS
supply undervoltage hysteresis — 0.2 —
V
ILK Offset supply leakage current — — 50 µA VB1,2,3 = VDC = GF =600 V,
VDC - VDCS = 20 V
Iqbs Quiescent VBS supply current — 45 120 All input/output in off status
Iqcc Quiescent VCC supply current — 2.5 4 mA All input/output in off status
Io+ Output high short circuit pulsed current,
HO1,2,3 100 200 — Vout = 0 V, PW </= 10 us
Io- Output low short circuit pulsed current,
HO1,2,3 190 350 — mA Vout = 15 V, PW </= 10 us
VOH High level output voltage, VBIAS – VO,
HO1,2,3 — 0.9 1.4 V IO = 20 mA
VOL Low level output voltage, VO, HO1,2,3 — 0.4 0.6