INCH-POUND
MIL-PRF-39012/67C
w/AMENDMENT 1
8 June 2016
SUPERSEDING
MIL-PRF-39012/67C
14 July 2011
PERFORMANCE SPECIFICATION SHEET
CONNECTORS, PLUGS, ELECTRICAL, COAXIAL, RADIO FREQUENCY,
SERIES SMB (CABLED, SOCKET CONTACT, CLASS 2)
This specification is approved for use by all Departments
and Agencies of the Department of Defense.
The requirements for acquiring the product described herein shall
consist of this specification sheet and MIL-PRF-39012.
NOTES:
1. Dim ensions are in inches.
2. Metric equivalents are in pa renthes es .
3. Metric equivalents are given for information only.
4. For dimension A, see table I.
5. W renc h flats are to accommodate standar d wrench o pen ing in ac cor danc e wit h FED -STD-H28,
appendix 10.
6. Dimension A defines the overall length of the connector when assembled to the cable.
7. Maximum overall diameter of the connector is .320 inch (8.13 mm).
8. All undimensioned pictorial configurations are for reference purposes only.
9. Series SMB, socket contact interface in accordance with MIL-STD-348.
FIGURE 1. General configuration.
AMSC N/A FSC 5935
MIL-PRF-39012/67C
w/AMENDMENT 1
2
TABLE I. Dash numbers, cross-reference, and dimensions.
Dash No.
M39012/67-
# Applicable cable group
from MIL-PRF-39012,
appendix B M17/
Typical mating
Connector 1/ Dimensions
Inches
(millimeters)
Maximum 2/
CATEGORY A FIELD SERVICEABLE (NO SPECIAL TOOLS REQUIRED)
0003 3/ 4/
Cable group I
93-RG178 * @
169-00001 %
M39012/68-0003
M39012/70-0003
A .88 (22.35)
0004 3/ 4/
Cable group II
113-RG316 * @
172-00001 %
94-RG179 ^
M39012/68-0004
M39012/70-0004
0103 3/
Cable group I
93-RG178 * @
169-00001 %
M39012/68-0103
M39012/70-0103
0104 3/
Cable group II
113-RG316 * @
172-00001 %
94-RG179 ^
M39012/68-0104
M39012/70-0104
4101 3/
Cable group I
93-RG178 * @
169-00001 %
M39012/68-4101
M39012/70-4101
4102 3/
Cable group II
113-RG316 * @
172-00001 %
94-RG179 ^
M39012/67-4102
M39012/69-4102
CATEGORY C FIELD REPLACEABLE (MIL-C-22520/5 BASIC CRIMP TOOL) 5/
0011 3/ 4/ Cable group I ~
93-RG178 * @
169-00001 %
M39012/68-0011
M39012/70-0011
A 1.10 (27.94)
0012 3/ 4/
Cable group IIa &
113-RG316 * @
172-00001 %
94-RG179 ^
M39012/68-0012
M39012/70-0012
See notes at end of table.
MIL-PRF-39012/67C
w/AMENDMENT 1
3
TABLE I. Dash numbers, cross-reference, and dimensionsContinued.
Dash No.
M39012/67-
# Applicable cable group
from MIL-PRF-39012,
appendix B
M17/
connector
1/
Dimensions
Inches 2/
(millimeters)
maximum
CATEGORY C FIELD REPLACEABLE (MIL-C-22520/5 BASIC CRIMP TOOL) 5/
0016 3/
Cable group I ~
93-RG178 * @
169-00001 %
M39012/68-0016
M39012/70-0016
A
1.10 (27.94)
0017 3/
Cable group IIa &
113-RG316 * @
172-00001 %
94-RG179 ^
M39012/68-0017
M39012/70-0017
4001 3/
Cable group I ~
93-RG178 * @
169-00001 %
M39012/68-4001
M39012/70-4001
4002 3/
Cable group IIa &
113-RG316 * @
172-00001 %
94-RG179 ^
M39012/68-4002
M39012/70-4002
1/ Mating connector Part or Identifying Number (PIN) is for reference only. All mating connectors
may not be listed.
2/ Dimensions are in inches. Metric equivalents are given for information only.
3/ These connectors have captivated center contacts.
4/ Connector bodies shall be gold plated in accordance with ASTM B488, type II, code C, class 1.27.
5/ Category C connectors are assembled by means of the applicable crimping tool in accordance
with MIL-DTL-22520 to the specified cable stripped as specified on figure 2.
# The latest version of each cable shall be applicable.
* Cable to be used when per f orming tests requiri ng c able exc ept as in notes @ and ^.
@ Cable to be used for the +200°C thermal shock tests.
^ These are not 50 ohm cables, therefore, when attached to the specified connectors, VSWR,
RF leakage and insertion loss are not applicable.
~ M22520/5-33 closure B or M22520/5-03 closure B.
& M22520/5-35 closure B or M22520/5-03 closure A.
% Caution is directed to the application of this cab le above 400 MH z. Attenua ti on is tested only at
400 MH z. SRL and power handling capabilities are not stipulated herein.
MIL-PRF-39012/67C
w/AMENDMENT 1
4
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
FIGURE 2. Cable stripping dimensions for category C connectors.
Inches
mm
.010
.020
.234
.516
.609
0.25
0.51
5.94
13.11
15.47
MIL-PRF-39012/67C
w/AMENDMENT 1
5
Inches mm
Inches mm
.002 0.05
.015 0.38
.005 0.13
.027 0.69
.006 0.15
.028 0.71
.007 0.18
.036 0.91
.009 0.23
.037 0.94
.010 0.25
.131 3.33
.011 0.28
.141 3.58
.012 0.30
.145 3.68
.014 0.36
.146 3.71
A
B
C
D
E
GAUGE # 1
.037
.036
.015
.014
.010
.009
.005 Max.
Rad.
.006
.002
Rad.
GAUGE # 2
.028
.027
.012
.011
.007
.006
NOTES:
1. Dimensions are in inches.
2. Metric equivalents are given for information only.
3. Gauge #1 to be used for longitudinal force initial engagement, and maximum engagement
requirement after 500 cycles.
4. Gauge #2 to be used for minimum disengagement requirement after 500 cycles of mating and
unmating.
5. Material steel with a 16 microinch finish.
FIGURE 3. Test gage for force to engage and dis e ng age tes t.
MIL-PRF-39012/67C
w/AMENDMENT 1
6
ENGINEERING DATA:
Nominal impedance: 50 ohms.
Frequency range: 0 to 4 GHz.
Voltage rating: The voltage rating shall be as specified in table II.
Temperature rating: -65°C to +165°C.
TABLE II. Voltage rating.
Cables
Voltage max. (sea level)
V rms
Voltage max. at 70,000 ft.
(4.437 kPa)
V rms
Cable group I
250
60
Cable group II, IIa,
335
85
REQUIREMENTS:
Dimensions and configuration: See figure 1 and MIL-STD-348.
Force to engage and disengage: See figure 3 for test gage.
Longitudinal force: 14 pounds, maximum.
Torque: N ot app lica bl e.
Coupling proof torque: Not applicable.
Inspection conditions: Torque not applicable.
Mating characteristics: See MIL-STD-348.
Center contact (socket):
Oversize test pin: .0215 inch diameter minimum (nonclosed entry contacts only).
Test pin finish: 16 microinches.
Insertion depth: .050 inch minimum.
Number of insertions: 1.
Insertion force test:
Steel test pin diameter: .021 inch, minimum.
Insertion depth: .050 inch, minimum.
Test pin finish: 16 microinches.
Insertion force: 2.5 pounds, maximum.
Withdrawal force test:
Steel test pin diameter: .019 inch, maximum.
Insertion depth: .050 inch, minimum.
Test pin finish: 16 microinches.
Withdrawal force: 1 ounce, minimum.
Hermetic seal: Not applicable.
Leakage (pressurized connectors): Not applicable.
Insulation resistance: In accordance with MIL-STD-202-302, test condition B, 1,000 megohms
minimum.
Center contact retention:
Axial force: 4 pounds minimum axial force. Applicable to captivated center contacts only.
Radial torque: Not applicable.
Resistance to test prod damage: Not applicable.
Salt atmosphere (corrosion): In accordance with MIL-STD-202-101, test condition B.
MIL-PRF-39012/67C
w/AMENDMENT 1
7
Voltage standing wave ratio (VSWR): From 500 MHz to 4 GHz, or approximately 80 percent of the
upper cutoff frequency of the cable, whichever is lower.
Cable group VSWR
I 1.30 + 0.04 (F) GHz
II, IIa, 1.25 + 0.04 (F) GHz
Swept frequency VSWR test setup:
Item 6: VSWR shall be less than 1.05 +.0025F (F in GHz).
Item 16: VSWR shall be less than 1.05 +.0 025F (F in GHz).
Second step of VSWR checkout procedure VSWR shall be less than 1.10 +.01F (F in GHz).
Group B inspection: VSWR shall be less than 1.08 +.017F (F in GHz).
Qualification and group C inspection: VSWR shall not exceed 1.15.
Connector durability: 500 cycles minimum at 12 cycles per minute maximum. The connector shall
meet mating characteristics and force to engage and disengage requirements.
Initial: 14 pounds, maximum.
Final: 14 pounds maximum engage and disengage; 2 pounds minimum disengagement.
Contact resistance: In milliohms, maximum.
Initial After environment
Center contact: 6.0 8.0
Outer contact: 1.0 1.5
Braid to body: 1 Not applicable
Dielectric withs ta ndi ng volt age at sea le ve l: In accordance with MIL-STD-202-301.
Cable group V rms (at sea level)
I 750
II, IIa 1,000
Vibration, high frequency: In accordance with MIL-STD-202-204, test cond ition B .
Shock: In accorda nce with MIL-STD-202-213, test condition B.
Thermal shock: In accordance with MIL-STD-202-107, test condition B, except test high temperature
shall be +85°C. High temperature shall be +200°C for connectors using +200°C cables (see tables I
and III).
Moisture resistance: Not applicable.
Corona leve l:
Altitude: 70,000 feet (4.437 kPa).
Cable group Volts, min.
I 185
II, IIa 250
MIL-PRF-39012/67C
w/AMENDMENT 1
8
RF high potential withstanding voltage:
Voltage and frequency: Tested at a frequency from 5 to 7.5 MHz.
Leakage current: Not applicable.
Cable group Volts, rms min.
I 500
II, IIa 700
Cable retention force: The cable retention force shall be as specified in table III.
TABLE III. Cable retention force. 1/ 2/
Cable dielectric
Outer diameter
Pounds, min. (N)
Non-crimp
Single braid
Crimp
Single braid
Center contact
Center contact
Captive
Captive
Inches, max. (mm)
.036 (0.91)
.066 (1.68)
13 (57.83)
25 (111.20)
13 (57.83)
25 (111.20)
1/ Dimensions are in inches.
2/ Metric equivalents are given for information only.
Coupling mechanism retention force: Not applicable.
RF leakage: -55 dB minimum, tested at frequency between 2 and 3 GHz..
RF insertion loss: .30 dB maximum tested at 4 GHz.
PIN: M39012/67 ( dash number in table I or IV as applicable).
Group qualification: See table V.
Cross reference of PIN: See table VI.
MIL-PRF-39012/67C
w/AMENDMENT 1
9
TABLE IV. Category B non-field replaceable (special tools may be required).
Dash No. 1/
M39012/67
# Applicable cable group
from MIL-PRF-39012,
appendix B
M17/
connector
2
Dimensions
Inches
(millimeters)
maximum
5/ 6/
B0008 3/ 4/
93-RG178 * @
169-00001 %
A 1.10 (27.94)
B0009 3/ 4/
113-RG316 * @
172-00001 %
119-RG174
173-00001 %
M39012/70B0009
B0010 3/ 4/
94-RG179 * @ ^
B0013 3/
93-RG178 * @
169-00001 %
B0014 3/
113-RG316 * @
172-00001 %
119-RG174
173-00001 %
M39012/70B0014
B0015 3/
94-RG179 ^ @ *
1/ For cross-reference of dash number to superseded PIN or type designation, see table VI.
2/ Mating connector PIN are for reference only. All mating connectors may not be listed.
3/ These connectors have captive center contacts.
4/ Connector bodies shall be gold plated in accordance with ASTM B488, type II, code C, class 1.27.
5/ Dimensions are in inches.
6/ Metric equivalents are given for information only.
# The latest version of each cable shall be applicable.
* Cable to be used when performing tests requiring cable except as in note @.
@ Cable to be used for the +200°C thermal shock tests.
% Caution is directed to the application of this cable above 400 MHz. Attenuation is tested only at 400
MHz. SRL and power handling capabilities are not stipulated herein.
^ These are not 50 ohm cables, therefore, when attached to the specified connectors, VSWR, RF
leakage and insertion loss are not applicable.
NOTE: Connectors mate with connectors of the same material only; Example: M39012/67-3001 mates
with M3901 2/68-3001, and M39012/67-4001 mates with M39012/68-4001.
NOT FOR ARMY, NAVY, OR AIR FORCE USE. FOR OE M USE ONL Y
MIL-PRF-39012/67C
w/AMENDMENT 1
10
TABLE V. Group qualification and retention testing.
Group
Submission and retention of
Qualification of any of the
following connectors 1/
M39012/
Qualifies the following
connectors
M39012/
I 67-0003
67-0003
67-0103 2/
II 67-0004
67-0004
67-0104 2/
III 67B0008
67B0008
67B0013 2/
IV 67B0009
67B0009
67B0010
67B0014 2/
67B0015 2/
V 67B0010
67B0010
67B0015 2/
VI 67-0011
67-0011
67-0016 2/
VII 67-0012
67-0012
67-0017 2/
1/ For qualification retention, where more than one part is listed in a group in this column, data may be
supplied on any of those parts in order to retain qualification for those parts in the corresponding right
hand column.
2/ Corrosion and contact resistance test data must be submitted to DSCC-VQ before qualification
approval may be granted.
NOTE: If a connector manufacturer produces a connector which meets all the requirements for two or
more connector PINs (within the same series), the manufacturer may receive qualification approval for
two or more connector PINs by qualifying the one connector. It is not necessary that such connectors be
in the same group. Each connector, however, must be marked with its own appropriate PIN. For group
qualification, the connectors must be of similar design. Qualification of connectors qualifies connectors of
the same material and finish only.
TABLE VI. Super ses s ion d ata.
Preferred PIN
M39012/67 1/
Superseded PIN
Or type designation
-0003
-0004
B0008
B0009
B0010
M39012/67-0001
M39012/67-0002
M39012/67-0008, M3 901 2/ 67-0005
M39012/67-0009, M3 901 2/ 67-0006
M39012/67-0010, M3 901 2/ 67-0007
1/ The “BPIN is required marking for connectors manufactured after 24 March 1987.
The connectors that are in stock or distribution that were previously qualified and marked with
the old PIN shall also be considered acceptable for Government use until stock is
purged. (Applies to category “B” P/N change only; M39012/XXBXXXX).
MIL-PRF-39012/67C
w/AMENDMENT 1
11
TABLE VII. Maintenance replacements for category B.
Categor y B
number 1/
Categor y C
dash number
Categor y A
dash number
B0008
B0009
B0010
B0013
B0014
B0015
-------
-------
-------
-------
-------
-------
0003
-------
-------
0103
-------
-------
1/ Category B connectors are for original installation only. They will not be stocked or procured by the
government.
Amendment notations. The margins of this specification are marked with vertical lines to indicate
modifications generated by this amendment. This was done as a convenience only and the
Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and
contractors are cautioned to evaluate the requirements of this document based on the entire content
irrespective of the marginal notations.
Referenced documents. In addition to MIL-PRF-39012, this document references the following:
FED-STD-H28
MIL-STD-202-204
MIL-STD-348
MIL-STD-202-101
MIL-STD-202-213
MIL-DTL-22520
MIL-STD-202-107
MIL-STD-202-301
MIL-C-22520/5
MIL-STD-202-302
ASTM B488
CONCLUDING MATERIAL
Custodians: Preparing activity:
Army - CR DLA - CC
Navy - EC
Air Force - 85 (Project 5935-2016-064)
DLA - CC
Revie w ac t i vit ies :
Army - AT, AV, EA, MI
Navy - AS, MC, OS, SA, SH
Air Force - 19, 99
NOTE: The activities listed above were interested in this document as of the date of this document.
Since organizations and responsibilities can change, you should verify the currency of the information
above using the ASSIST Online database at https://assist.dla.mil .