Isocom Ltd reserves the right to change the details on this specification without notice. Please consult Isocom Ltd prior to use.
Isocom Ltd cannot accept liability for any errors or omissions.
For sales enquiries, or further information, please contact our sales office at:
Isocom Ltd, Hutton Close, Crowther Industrial Estate, District 3, Washington, NE38 0AH
Tel: +44 0191 4166 546 Fax: +44 0191 4155 055 Email Isocom@isocomoptocouplers.com
Or go to the Isocom Website @: Http://www.isocom.uk.com
Electro-optical Characteristics (Ta=25°C)
INPUT PARAMETER CONDITIONS MIN TYP MAX UNIT
VF Forward Voltage IF=0.3mA 0.75 V
I
F=10mA 1.5 V
IR Reverse Current VR=3.0V 10 µA
VR Reverse Breakdown Voltage IR=10µA 3.0 V
OUTPUT PARAMETER CONDITIONS MIN TYP MAX UNIT
VCC Operating Voltage Range 3 15 V
I6 OFF Supply Current IF=0, VCC=5V 5.0 mA
IOH Output Current High IF=0, VCC=VO=15V 100 µA
COUPLED PARAMETER CONDITIONS MIN TYP MAX UNIT
I6 ON Supply Current IF=5mA, VCC=5V 5.0 mA
VOL Output Voltage Low RL=270ohm, VCC=5V 0.4 V
IF ON Turn-On Threshold Current
MOC5007 1.6 mA
MOC5008 4 mA
MOC5009 10 mA
IF OFF Turn-Off Threshold Current 0.3 0.9 mA
IF OFF/IF ON Hysteresis Ratio 0.50 0.90
tON Turn-on Time RE=1200ohm 0.57 µs
tF Fall Time C=270pF 0.09 µs
tOFF Turn-off Time f<=100kHz 1.40 µs
tR Rise Time tP=1µs 0.05 µs