uA9636AC
DUAL LINE DRIVER WITH ADJUSTABLE SLEW RATE
SLLS110B – OCTOBER 1980 – REVISED MAY 1995
2POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
schematics of inputs and outputs
VCC+
EQUIVALENT OF EACH INPUT TYPICAL OF ALL OUTPUTS
Input
VCC±
Current
Source Current
Source
VCC+
Output
VCC±
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
Positive supply voltage range, VCC+(see Note 1) VCC– to 15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Negative supply voltage range, VCC– 0.5 V to –15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage, VO ±15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, IO ±150 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, TA 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, Tstg –65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only , and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may af fect device reliability.
NOTE 1: All voltage values are with respect to the network ground terminal.
DISSIPATION RATING TABLE
T
≤ 25°CDERATING FACTOR T
= 70°C
POWER RATING ABOVE TA = 25°C
POWER RATING
D725 mW 5.8 mW/°C 464 mW
P1000 mW 8.0 mW/°C 640 mW
recommended operating conditions
MIN NOM MAX UNIT
Positive supply voltage, VCC+ 10.8 12 13.2 V
Negative supply voltage, VCC– –10.8 –12 –13.2 V
High-level input voltage, VIH 2 V
Low-level input voltage, VIL 0.8 V
W ave-shaping resistor, R(WS) 10 1000 kΩ
Operating free-air temperature, TA0 70 °C